Merge branch 'devel' into rtu-redstone-enhancements
This commit is contained in:
@@ -3,20 +3,23 @@ local rsio = require("scada-common.rsio")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local logic = require("supervisor.unitlogic")
|
||||
local alarm_ctl = require("supervisor.alarm_ctl")
|
||||
local unit_logic = require("supervisor.unit_logic")
|
||||
|
||||
local plc = require("supervisor.session.plc")
|
||||
local rsctl = require("supervisor.session.rsctl")
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local WASTE_MODE = types.WASTE_MODE
|
||||
local WASTE = types.WASTE_PRODUCT
|
||||
local AISTATE = alarm_ctl.AISTATE
|
||||
|
||||
local ALARM = types.ALARM
|
||||
local PRIO = types.ALARM_PRIORITY
|
||||
local ALARM_STATE = types.ALARM_STATE
|
||||
local TRI_FAIL = types.TRI_FAIL
|
||||
local PRIO = types.ALARM_PRIORITY
|
||||
local RTU_ID_FAIL = types.RTU_ID_FAIL
|
||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local TRI_FAIL = types.TRI_FAIL
|
||||
local WASTE_MODE = types.WASTE_MODE
|
||||
local WASTE = types.WASTE_PRODUCT
|
||||
|
||||
local PLC_S_CMDS = plc.PLC_S_CMDS
|
||||
|
||||
@@ -37,23 +40,6 @@ local DT_KEYS = {
|
||||
TurbinePower = "TPR"
|
||||
}
|
||||
|
||||
---@enum ALARM_INT_STATE
|
||||
local AISTATE = {
|
||||
INACTIVE = 1,
|
||||
TRIPPING = 2,
|
||||
TRIPPED = 3,
|
||||
ACKED = 4,
|
||||
RING_BACK = 5,
|
||||
RING_BACK_TRIPPING = 6
|
||||
}
|
||||
|
||||
---@class alarm_def
|
||||
---@field state ALARM_INT_STATE internal alarm state
|
||||
---@field trip_time integer time (ms) when first tripped
|
||||
---@field hold_time integer time (s) to hold before tripping
|
||||
---@field id ALARM alarm ID
|
||||
---@field tier integer alarm urgency tier (0 = highest)
|
||||
|
||||
-- burn rate to idle at
|
||||
local IDLE_RATE = 0.01
|
||||
|
||||
@@ -81,7 +67,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
|
||||
num_boilers = num_boilers,
|
||||
num_turbines = num_turbines,
|
||||
aux_coolant = aux_coolant,
|
||||
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
|
||||
types = { DT_KEYS = DT_KEYS },
|
||||
-- rtus
|
||||
rtu_list = {}, ---@type unit_session[][]
|
||||
redstone = {}, ---@type redstone_session[]
|
||||
@@ -597,20 +583,20 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
|
||||
_dt__compute_all()
|
||||
|
||||
-- update annunciator logic
|
||||
logic.update_annunciator(self)
|
||||
unit_logic.update_annunciator(self)
|
||||
|
||||
-- update alarm status
|
||||
logic.update_alarms(self)
|
||||
unit_logic.update_alarms(self)
|
||||
|
||||
-- if in auto mode, SCRAM on certain alarms
|
||||
logic.update_auto_safety(public, self)
|
||||
unit_logic.update_auto_safety(self, public)
|
||||
|
||||
-- update status text
|
||||
logic.update_status_text(self)
|
||||
unit_logic.update_status_text(self)
|
||||
|
||||
-- handle redstone I/O
|
||||
if #self.redstone > 0 then
|
||||
logic.handle_redstone(self)
|
||||
unit_logic.handle_redstone(self)
|
||||
elseif not self.plc_cache.rps_trip then
|
||||
self.em_cool_opened = false
|
||||
end
|
||||
@@ -775,10 +761,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
|
||||
|
||||
-- acknowledge all alarms (if possible)
|
||||
function public.ack_all()
|
||||
for i = 1, #self.db.alarm_states do
|
||||
if self.db.alarm_states[i] == ALARM_STATE.TRIPPED then
|
||||
self.db.alarm_states[i] = ALARM_STATE.ACKED
|
||||
end
|
||||
for id, state in pairs(self.db.alarm_states) do
|
||||
if state == ALARM_STATE.TRIPPED then self.db.alarm_states[id] = ALARM_STATE.ACKED end
|
||||
end
|
||||
end
|
||||
|
||||
|
||||
Reference in New Issue