This commit is contained in:
@@ -387,6 +387,19 @@ function plc.rps_init(reactor, is_formed)
|
||||
if not quiet then log.info("RPS: reset") end
|
||||
end
|
||||
|
||||
-- reset the automatic and timeout trip flags, then clear trip if that was the trip cause
|
||||
function public.auto_reset()
|
||||
self.state[state_keys.automatic] = false
|
||||
self.state[state_keys.timeout] = false
|
||||
|
||||
if self.trip_cause == rps_status_t.automatic or self.trip_cause == rps_status_t.timeout then
|
||||
self.trip_cause = rps_status_t.ok
|
||||
self.tripped = false
|
||||
end
|
||||
|
||||
log.info("RPS: auto reset")
|
||||
end
|
||||
|
||||
return public
|
||||
end
|
||||
|
||||
@@ -808,6 +821,10 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
|
||||
-- reset the RPS status
|
||||
rps.reset()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.RPS_AUTO_RESET then
|
||||
-- reset automatic SCRAM and timeout trips
|
||||
rps.auto_reset()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.AUTO_BURN_RATE then
|
||||
-- automatic control requested a new burn rate
|
||||
if (packet.length == 3) and (type(packet.data[1]) == "number") and (type(packet.data[3]) == "number") then
|
||||
|
||||
Reference in New Issue