reworked computed status logic and handle dynamic tank data

This commit is contained in:
Mikayla
2024-12-10 04:31:53 +00:00
parent 49b545ba2c
commit 20bffec79f
4 changed files with 133 additions and 129 deletions

View File

@@ -9,6 +9,10 @@ local util = require("scada-common.util")
local ALARM = types.ALARM
local ALARM_STATE = types.ALARM_STATE
local BLR_STATE = types.BOILER_STATE
local TRB_STATE = types.TURBINE_STATE
local TNK_STATE = types.TANK_STATE
local io ---@type pocket_ioctl
local iorx = {} ---@class iorx
@@ -61,10 +65,12 @@ function iorx.record_unit_data(data)
local unit = io.units[data[1]]
unit.connected = data[2]
unit.rtu_hw = data[3]
local comp_statuses = data[3]
unit.a_group = data[4]
unit.alarms = data[5]
local next_c_stat = 1
unit.unit_ps.publish("auto_group_id", unit.a_group)
unit.unit_ps.publish("auto_group", types.AUTO_GROUP_NAMES[unit.a_group + 1])
@@ -152,43 +158,27 @@ function iorx.record_unit_data(data)
local control_status = 1
local reactor_status = 1
local reactor_state = 1
local rps_status = 1
if unit.connected then
-- update RPS status
if unit.reactor_data.rps_tripped then
control_status = 2
if unit.reactor_data.rps_trip_cause == "manual" then
reactor_state = 4 -- disabled
rps_status = 3
else
reactor_state = 6 -- SCRAM
rps_status = 2
end
rps_status = util.trinary(unit.reactor_data.rps_trip_cause == "manual", 3, 2)
else
rps_status = 4
reactor_state = 4
end
reactor_status = 4 -- ok, until proven otherwise
-- update reactor/control status
if unit.reactor_data.mek_status.status then
reactor_status = 4
reactor_state = 5 -- running
control_status = util.trinary(unit.annunciator.AutoControl, 4, 3)
else
if unit.reactor_data.no_reactor then
reactor_status = 2
reactor_state = 3 -- faulted
elseif not unit.reactor_data.formed then
elseif (not unit.reactor_data.formed) or unit.reactor_data.rps_status.force_dis then
reactor_status = 3
reactor_state = 2 -- not formed
elseif unit.reactor_data.rps_status.force_dis then
reactor_status = 3
reactor_state = 7 -- force disabled
else
reactor_status = 4
end
end
@@ -213,9 +203,11 @@ function iorx.record_unit_data(data)
unit.unit_ps.publish("U_ControlStatus", control_status)
unit.unit_ps.publish("U_ReactorStatus", reactor_status)
unit.unit_ps.publish("U_ReactorStateStatus", reactor_state)
unit.unit_ps.publish("U_ReactorStateStatus", comp_statuses[next_c_stat])
unit.unit_ps.publish("U_RPS", rps_status)
next_c_stat = next_c_stat + 1
--#endregion
--#region RTU Devices
@@ -225,32 +217,26 @@ function iorx.record_unit_data(data)
for id = 1, #unit.boiler_data_tbl do
local boiler = unit.boiler_data_tbl[id]
local ps = unit.boiler_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local boiler_status = 1
local computed_status = 1
if unit.rtu_hw.boilers[id].connected then
if unit.rtu_hw.boilers[id].faulted then
if c_stat ~= BLR_STATE.OFFLINE then
if c_stat == BLR_STATE.FAULT then
boiler_status = 3
computed_status = 3
elseif boiler.formed then
elseif c_stat ~= BLR_STATE.UNFORMED then
boiler_status = 4
if boiler.state.boil_rate > 0 then
computed_status = 5
else
computed_status = 4
end
else
boiler_status = 2
computed_status = 2
end
_record_multiblock_status(unit.rtu_hw.boilers[id].faulted, boiler, ps)
_record_multiblock_status(c_stat == BLR_STATE.FAULT, boiler, ps)
end
ps.publish("BoilerStatus", boiler_status)
ps.publish("BoilerStateStatus", computed_status)
ps.publish("BoilerStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end
unit.turbine_data_tbl = data[9]
@@ -258,38 +244,55 @@ function iorx.record_unit_data(data)
for id = 1, #unit.turbine_data_tbl do
local turbine = unit.turbine_data_tbl[id]
local ps = unit.turbine_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local turbine_status = 1
local computed_status = 1
if unit.rtu_hw.turbines[id].connected then
if unit.rtu_hw.turbines[id].faulted then
if c_stat ~= TRB_STATE.OFFLINE then
if c_stat == TRB_STATE.FAULT then
turbine_status = 3
computed_status = 3
elseif turbine.formed then
turbine_status = 4
if turbine.tanks.energy_fill >= 0.99 then
computed_status = 6
elseif turbine.state.flow_rate < 100 then
computed_status = 4
else
computed_status = 5
end
else
turbine_status = 2
computed_status = 2
end
_record_multiblock_status(unit.rtu_hw.turbines[id].faulted, turbine, ps)
_record_multiblock_status(c_stat == TRB_STATE.FAULT, turbine, ps)
end
ps.publish("TurbineStatus", turbine_status)
ps.publish("TurbineStateStatus", computed_status)
ps.publish("TurbineStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end
unit.tank_data_tbl = data[10]
for id = 1, #unit.tank_data_tbl do
local tank = unit.tank_data_tbl[id]
local ps = unit.tank_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local tank_status = 1
if c_stat ~= TNK_STATE.OFFLINE then
if c_stat == TNK_STATE.FAULT then
tank_status = 3
elseif tank.formed then
tank_status = 4
else
tank_status = 2
end
_record_multiblock_status(c_stat == TNK_STATE.FAULT, tank, ps)
end
ps.publish("DynamicTankStatus", tank_status)
ps.publish("DynamicTankStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end
unit.last_rate_change_ms = data[11]
unit.turbine_flow_stable = data[12]