#580 supervisor network configurator updates
This commit is contained in:
@@ -33,7 +33,8 @@ local CENTER = core.ALIGN.CENTER
|
||||
local changes = {
|
||||
{ "v1.2.12", { "Added front panel UI theme", "Added color accessibility modes" } },
|
||||
{ "v1.3.2", { "Added standard with black off state color mode", "Added blue indicator color modes" } },
|
||||
{ "v1.6.0", { "Added sodium emergency coolant option" } }
|
||||
{ "v1.6.0", { "Added sodium emergency coolant option" } },
|
||||
{ "v1.8.0", { "Added support for both wired and wireless networking" } }
|
||||
}
|
||||
|
||||
---@class svr_configurator
|
||||
@@ -92,6 +93,13 @@ local tmp_cfg = {
|
||||
TankFluidTypes = {}, ---@type integer[] which type of fluid each tank in the tank list should be containing
|
||||
AuxiliaryCoolant = {}, ---@type boolean[] if a unit has auxiliary coolant
|
||||
ExtChargeIdling = false,
|
||||
WirelessModem = true, ---@type boolean
|
||||
WiredModem = false, ---@type string|false
|
||||
PLC_Listen = 1, ---@type LISTEN_MODE
|
||||
RTU_Listen = 1, ---@type LISTEN_MODE
|
||||
CRD_Listen = 1, ---@type LISTEN_MODE
|
||||
PocketEnabled = true, ---@type boolean
|
||||
PocketTest = true, ---@type boolean
|
||||
SVR_Channel = nil, ---@type integer
|
||||
PLC_Channel = nil, ---@type integer
|
||||
RTU_Channel = nil, ---@type integer
|
||||
@@ -101,13 +109,6 @@ local tmp_cfg = {
|
||||
RTU_Timeout = nil, ---@type number
|
||||
CRD_Timeout = nil, ---@type number
|
||||
PKT_Timeout = nil, ---@type number
|
||||
WirelessModem = true, ---@type boolean
|
||||
WiredModem = false, ---@type string|false
|
||||
PLC_Listen = 0, ---@type LISTEN_MODE
|
||||
RTU_Listen = 0, ---@type LISTEN_MODE
|
||||
CRD_Listen = 0, ---@type LISTEN_MODE
|
||||
PocketEnabled = true, ---@type boolean
|
||||
PocketTest = true, ---@type boolean
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
LogMode = 0, ---@type LOG_MODE
|
||||
@@ -133,6 +134,13 @@ local fields = {
|
||||
{ "TankFluidTypes", "Tank Fluid Types", {} },
|
||||
{ "AuxiliaryCoolant", "Auxiliary Water Coolant", {} },
|
||||
{ "ExtChargeIdling", "Extended Charge Idling", false },
|
||||
{ "WirelessModem", "Wireless/Ender Comms Modem", true },
|
||||
{ "WiredModem", "Wired Comms Modem", false },
|
||||
{ "PLC_Listen", "PLC Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "RTU_Listen", "RTU Gateway Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "CRD_Listen", "Coordinator Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "PocketEnabled", "Pocket Connectivity", true },
|
||||
{ "PocketTest", "Pocket Testing Features", true },
|
||||
{ "SVR_Channel", "SVR Channel", 16240 },
|
||||
{ "PLC_Channel", "PLC Channel", 16241 },
|
||||
{ "RTU_Channel", "RTU Channel", 16242 },
|
||||
@@ -142,13 +150,6 @@ local fields = {
|
||||
{ "RTU_Timeout", "RTU Connection Timeout", 5 },
|
||||
{ "CRD_Timeout", "CRD Connection Timeout", 5 },
|
||||
{ "PKT_Timeout", "PKT Connection Timeout", 5 },
|
||||
{ "WirelessModem", "Wireless/Ender Comms Modem", true },
|
||||
{ "WiredModem", "Wired Comms Modem", false },
|
||||
{ "PLC_Listen", "PLC Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "RTU_Listen", "RTU Gateway Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "CRD_Listen", "Coordinator Listen Mode", types.LISTEN_MODE.WIRELESS },
|
||||
{ "PocketEnabled", "Pocket Connectivity", true },
|
||||
{ "PocketTest", "Pocket Testing Features", true },
|
||||
{ "TrustedRange", "Trusted Range", 0 },
|
||||
{ "AuthKey", "Facility Auth Key" , "" },
|
||||
{ "LogMode", "Log Mode", log.MODE.APPEND },
|
||||
|
||||