moved ETA string generation to icontrol

This commit is contained in:
Mikayla Fischler
2025-01-11 11:57:06 -05:00
parent 4a4234c8c8
commit 2d83de8b88
3 changed files with 46 additions and 80 deletions

View File

@@ -495,6 +495,49 @@ end
--#region Statuses
-- generate the text string for the induction matrix charge/discharge ETA
---@param eta_ms number eta in milliseconds
local function gen_eta_text(eta_ms)
local str, pre = "", util.trinary(eta_ms >= 0, "Full in ", "Empty in ")
local seconds = math.abs(eta_ms) / 1000
local minutes = seconds / 60
local hours = minutes / 60
local days = hours / 24
if math.abs(eta_ms) < 1000 or (eta_ms ~= eta_ms) then
-- really small or NaN
str = "No ETA"
elseif days < 1000 then
days = math.floor(days)
hours = math.floor(hours % 24)
minutes = math.floor(minutes % 60)
seconds = math.floor(seconds % 60)
if days > 0 then
str = days .. "d"
elseif hours > 0 then
str = hours .. "h " .. minutes .. "m"
elseif minutes > 0 then
str = minutes .. "m " .. seconds .. "s"
elseif seconds > 0 then
str = seconds .. "s"
end
str = pre .. str
else
local years = math.floor(days / 365.25)
if years <= 99999999 then
str = pre .. years .. "y"
else
str = pre .. "eras"
end
end
return str
end
-- record and publish multiblock status data
---@param entry any
---@param data imatrix_session_db|sps_session_db|dynamicv_session_db|turbinev_session_db|boilerv_session_db
@@ -616,6 +659,7 @@ function iocontrol.update_facility_status(status)
ps.publish("avg_inflow", in_f)
ps.publish("avg_outflow", out_f)
ps.publish("eta_ms", eta)
ps.publish("eta_string", gen_eta_text(eta or 0))
ps.publish("is_charging", in_f > out_f)
ps.publish("is_discharging", out_f > in_f)