#169 startup rate high; also changed how clearing ASCRAM status and updating indicators works
This commit is contained in:
@@ -301,6 +301,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
if (self.mode ~= PROCESS.MATRIX_FAULT_IDLE) and (self.mode ~= PROCESS.SYSTEM_ALARM_IDLE) then
|
||||
-- auto clear ASCRAM
|
||||
self.ascram = false
|
||||
self.ascram_reason = AUTO_SCRAM.NONE
|
||||
end
|
||||
|
||||
local blade_count = nil
|
||||
@@ -372,12 +373,18 @@ function facility.new(num_reactors, cooling_conf)
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if not self.units_ready then
|
||||
self.status_text = { "NOT READY", "assigned units not ready" }
|
||||
elseif self.start_fail == START_STATUS.NO_UNITS and assign_count == 0 then
|
||||
self.status_text = { "START FAILED", "no units were assigned" }
|
||||
elseif self.start_fail == START_STATUS.BLADE_MISMATCH then
|
||||
self.status_text = { "START FAILED", "turbine blade count mismatch" }
|
||||
else
|
||||
self.status_text = { "IDLE", "control disengaged" }
|
||||
-- clear ASCRAM once ready
|
||||
self.ascram = false
|
||||
self.ascram_reason = AUTO_SCRAM.NONE
|
||||
|
||||
if self.start_fail == START_STATUS.NO_UNITS and assign_count == 0 then
|
||||
self.status_text = { "START FAILED", "no units were assigned" }
|
||||
elseif self.start_fail == START_STATUS.BLADE_MISMATCH then
|
||||
self.status_text = { "START FAILED", "turbine blade count mismatch" }
|
||||
else
|
||||
self.status_text = { "IDLE", "control disengaged" }
|
||||
end
|
||||
end
|
||||
elseif self.mode == PROCESS.MAX_BURN then
|
||||
-- run units at their limits
|
||||
@@ -522,7 +529,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
next_mode = self.return_mode
|
||||
log.info("FAC: exiting matrix fault idle state due to fault resolution")
|
||||
elseif self.ascram_reason == AUTO_SCRAM.CRIT_ALARM then
|
||||
next_mode = PROCESS.INACTIVE
|
||||
next_mode = PROCESS.SYSTEM_ALARM_IDLE
|
||||
log.info("FAC: exiting matrix fault idle state due to critical unit alarm")
|
||||
end
|
||||
elseif self.mode == PROCESS.SYSTEM_ALARM_IDLE then
|
||||
@@ -545,55 +552,54 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
local astatus = self.ascram_status
|
||||
|
||||
if (self.mode ~= PROCESS.INACTIVE) and (self.mode ~= PROCESS.SYSTEM_ALARM_IDLE) then
|
||||
if self.induction[1] ~= nil then
|
||||
local matrix = self.induction[1] ---@type unit_session
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
if self.induction[1] ~= nil then
|
||||
local matrix = self.induction[1] ---@type unit_session
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
|
||||
-- clear matrix disconnected
|
||||
if astatus.matrix_dc then
|
||||
astatus.matrix_dc = false
|
||||
log.info("FAC: induction matrix reconnected, clearing ASCRAM condition")
|
||||
end
|
||||
|
||||
-- check matrix fill too high
|
||||
local was_fill = astatus.matrix_fill
|
||||
astatus.matrix_fill = (db.tanks.energy_fill >= HIGH_CHARGE) or (astatus.matrix_fill and db.tanks.energy_fill > RE_ENABLE_CHARGE)
|
||||
|
||||
if was_fill and not astatus.matrix_fill then
|
||||
log.info("FAC: charge state of induction matrix entered acceptable range <= " .. (RE_ENABLE_CHARGE * 100) .. "%")
|
||||
end
|
||||
|
||||
-- check for critical unit alarms
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
|
||||
if u.has_critical_alarm() then
|
||||
log.info(util.c("FAC: emergency exit of process control due to critical unit alarm (unit ", u.get_id(), ")"))
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
-- check for facility radiation
|
||||
if self.envd[1] ~= nil then
|
||||
local envd = self.envd[1] ---@type unit_session
|
||||
local e_db = envd.get_db() ---@type envd_session_db
|
||||
|
||||
astatus.radiation = e_db.radiation_raw > RADIATION_ALARM_LEVEL
|
||||
else
|
||||
-- don't clear, if it is true then we lost it with high radiation, so just keep alarming
|
||||
-- operator can restart the system or hit the stop/reset button
|
||||
end
|
||||
|
||||
-- system not ready, will need to restart GEN_RATE mode
|
||||
-- clears when we enter the fault waiting state
|
||||
astatus.gen_fault = self.mode == PROCESS.GEN_RATE and not self.units_ready
|
||||
else
|
||||
astatus.matrix_dc = true
|
||||
-- clear matrix disconnected
|
||||
if astatus.matrix_dc then
|
||||
astatus.matrix_dc = false
|
||||
log.info("FAC: induction matrix reconnected, clearing ASCRAM condition")
|
||||
end
|
||||
|
||||
-- log.debug(util.c("dc: ", astatus.matrix_dc, " fill: ", astatus.matrix_fill, " crit: ", astatus.crit_alarm, " gen: ", astatus.gen_fault))
|
||||
-- check matrix fill too high
|
||||
local was_fill = astatus.matrix_fill
|
||||
astatus.matrix_fill = (db.tanks.energy_fill >= HIGH_CHARGE) or (astatus.matrix_fill and db.tanks.energy_fill > RE_ENABLE_CHARGE)
|
||||
|
||||
if was_fill and not astatus.matrix_fill then
|
||||
log.info("FAC: charge state of induction matrix entered acceptable range <= " .. (RE_ENABLE_CHARGE * 100) .. "%")
|
||||
end
|
||||
|
||||
-- check for critical unit alarms
|
||||
astatus.crit_alarm = false
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
|
||||
if u.has_critical_alarm() then
|
||||
astatus.crit_alarm = true
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
-- check for facility radiation
|
||||
if self.envd[1] ~= nil then
|
||||
local envd = self.envd[1] ---@type unit_session
|
||||
local e_db = envd.get_db() ---@type envd_session_db
|
||||
|
||||
astatus.radiation = e_db.radiation_raw > RADIATION_ALARM_LEVEL
|
||||
else
|
||||
-- don't clear, if it is true then we lost it with high radiation, so just keep alarming
|
||||
-- operator can restart the system or hit the stop/reset button
|
||||
end
|
||||
|
||||
-- system not ready, will need to restart GEN_RATE mode
|
||||
-- clears when we enter the fault waiting state
|
||||
astatus.gen_fault = self.mode == PROCESS.GEN_RATE and not self.units_ready
|
||||
else
|
||||
astatus.matrix_dc = true
|
||||
end
|
||||
|
||||
if (self.mode ~= PROCESS.INACTIVE) and (self.mode ~= PROCESS.SYSTEM_ALARM_IDLE) then
|
||||
local scram = astatus.matrix_dc or astatus.matrix_fill or astatus.crit_alarm or astatus.gen_fault
|
||||
|
||||
if scram and not self.ascram then
|
||||
@@ -611,6 +617,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.status_text = { "AUTOMATIC SCRAM", "critical unit alarm tripped" }
|
||||
|
||||
log.info("FAC: automatic SCRAM due to critical unit alarm")
|
||||
log.warning("FAC: emergency exit of process control due to critical unit alarm")
|
||||
elseif astatus.radiation then
|
||||
next_mode = PROCESS.SYSTEM_ALARM_IDLE
|
||||
self.ascram_reason = AUTO_SCRAM.RADIATION
|
||||
|
||||
Reference in New Issue