#401 cleanup and global RTT limit constants
This commit is contained in:
@@ -2,16 +2,12 @@
|
||||
-- Data Bus - Central Communication Linking for Supervisor Front Panel
|
||||
--
|
||||
|
||||
local psil = require("scada-common.psil")
|
||||
local util = require("scada-common.util")
|
||||
local const = require("scada-common.constants")
|
||||
local psil = require("scada-common.psil")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local pgi = require("supervisor.panel.pgi")
|
||||
|
||||
-- nominal RTT is ping (0ms to 10ms usually) + 150ms for SV main loop tick
|
||||
-- ensure in sync with pocket computer list app
|
||||
local WARN_RTT = 300 -- 2x as long as expected w/ 0 ping
|
||||
local HIGH_RTT = 500 -- 3.33x as long as expected w/ 0 ping
|
||||
|
||||
local databus = {}
|
||||
|
||||
-- databus PSIL
|
||||
@@ -60,9 +56,9 @@ end
|
||||
function databus.tx_plc_rtt(reactor_id, rtt)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt", rtt)
|
||||
|
||||
if rtt > HIGH_RTT then
|
||||
if rtt > const.HIGH_RTT then
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.red)
|
||||
elseif rtt > WARN_RTT then
|
||||
elseif rtt > const.WARN_RTT then
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.green_hc)
|
||||
@@ -91,9 +87,9 @@ end
|
||||
function databus.tx_rtu_rtt(session_id, rtt)
|
||||
databus.ps.publish("rtu_" .. session_id .. "_rtt", rtt)
|
||||
|
||||
if rtt > HIGH_RTT then
|
||||
if rtt > const.HIGH_RTT then
|
||||
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.red)
|
||||
elseif rtt > WARN_RTT then
|
||||
elseif rtt > const.WARN_RTT then
|
||||
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.green_hc)
|
||||
@@ -130,9 +126,9 @@ end
|
||||
function databus.tx_crd_rtt(rtt)
|
||||
databus.ps.publish("crd_rtt", rtt)
|
||||
|
||||
if rtt > HIGH_RTT then
|
||||
if rtt > const.HIGH_RTT then
|
||||
databus.ps.publish("crd_rtt_color", colors.red)
|
||||
elseif rtt > WARN_RTT then
|
||||
elseif rtt > const.WARN_RTT then
|
||||
databus.ps.publish("crd_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("crd_rtt_color", colors.green_hc)
|
||||
@@ -161,9 +157,9 @@ end
|
||||
function databus.tx_pdg_rtt(session_id, rtt)
|
||||
databus.ps.publish("pdg_" .. session_id .. "_rtt", rtt)
|
||||
|
||||
if rtt > HIGH_RTT then
|
||||
if rtt > const.HIGH_RTT then
|
||||
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.red)
|
||||
elseif rtt > WARN_RTT then
|
||||
elseif rtt > const.WARN_RTT then
|
||||
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.green_hc)
|
||||
|
||||
Reference in New Issue