#580 work on supervisor wired modem configuration
This commit is contained in:
@@ -1,6 +1,7 @@
|
||||
local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
local pcie = require("supervisor.pcie")
|
||||
|
||||
local themes = require("graphics.themes")
|
||||
|
||||
@@ -123,11 +124,10 @@ end
|
||||
-- supervisory controller communications
|
||||
---@nodiscard
|
||||
---@param _version string supervisor version
|
||||
---@param nic nic network interface device
|
||||
---@param fp_ok boolean if the front panel UI is running
|
||||
---@param facility facility facility instance
|
||||
---@diagnostic disable-next-line: unused-local
|
||||
function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
function supervisor.comms(_version, fp_ok, facility)
|
||||
-- print a log message to the terminal as long as the UI isn't running
|
||||
local function println(message) if not fp_ok then util.println_ts(message) end end
|
||||
|
||||
@@ -137,20 +137,24 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
|
||||
comms.set_trusted_range(config.TrustedRange)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- configure modem channels
|
||||
nic.closeAll()
|
||||
nic.open(config.SVR_Channel)
|
||||
pcie.nic.reset_open(config.SVR_Channel)
|
||||
|
||||
-- pass system data and objects to svsessions
|
||||
svsessions.init(nic, fp_ok, config, facility)
|
||||
svsessions.init(fp_ok, config, facility)
|
||||
|
||||
-- get nic references
|
||||
local c_nic = pcie.nic.core
|
||||
local p_nic = pcie.nic.pocket
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- send an establish request response
|
||||
---@param nic nic
|
||||
---@param packet scada_packet
|
||||
---@param ack ESTABLISH_ACK
|
||||
---@param data? any optional data
|
||||
local function _send_establish(packet, ack, data)
|
||||
local function _send_establish(nic, packet, ack, data)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
@@ -175,36 +179,33 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
---@param distance integer
|
||||
---@return modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil packet
|
||||
function public.parse_packet(side, sender, reply_to, message, distance)
|
||||
local s_pkt = nic.receive(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = c_nic.receive(side, sender, reply_to, message, distance)
|
||||
|
||||
if p_nic and not s_pkt then
|
||||
-- try for it being from the pocket modem
|
||||
s_pkt = p_nic.receive(side, sender, reply_to, message, distance)
|
||||
end
|
||||
|
||||
if s_pkt then
|
||||
-- get as MODBUS TCP packet
|
||||
if s_pkt.protocol() == PROTOCOL.MODBUS_TCP then
|
||||
local m_pkt = comms.modbus_packet()
|
||||
if m_pkt.decode(s_pkt) then
|
||||
pkt = m_pkt.get()
|
||||
end
|
||||
if m_pkt.decode(s_pkt) then pkt = m_pkt.get() end
|
||||
-- get as RPLC packet
|
||||
elseif s_pkt.protocol() == PROTOCOL.RPLC then
|
||||
local rplc_pkt = comms.rplc_packet()
|
||||
if rplc_pkt.decode(s_pkt) then
|
||||
pkt = rplc_pkt.get()
|
||||
end
|
||||
if rplc_pkt.decode(s_pkt) then pkt = rplc_pkt.get() end
|
||||
-- get as SCADA management packet
|
||||
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
local mgmt_pkt = comms.mgmt_packet()
|
||||
if mgmt_pkt.decode(s_pkt) then
|
||||
pkt = mgmt_pkt.get()
|
||||
end
|
||||
if mgmt_pkt.decode(s_pkt) then pkt = mgmt_pkt.get() end
|
||||
-- get as coordinator packet
|
||||
elseif s_pkt.protocol() == PROTOCOL.SCADA_CRDN then
|
||||
local crdn_pkt = comms.crdn_packet()
|
||||
if crdn_pkt.decode(s_pkt) then
|
||||
pkt = crdn_pkt.get()
|
||||
end
|
||||
if crdn_pkt.decode(s_pkt) then pkt = crdn_pkt.get() end
|
||||
else
|
||||
log.debug("attempted parse of illegal packet type " .. s_pkt.protocol(), true)
|
||||
log.debug("receive[" .. side .. "] attempted parse of illegal packet type " .. s_pkt.protocol(), true)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -257,7 +258,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.info(util.c("dropping PLC establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PLC then
|
||||
-- PLC linking request
|
||||
if packet.length == 4 and type(packet.data[4]) == "number" then
|
||||
@@ -270,7 +271,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.warning(util.c("PLC_ESTABLISH: denied assignment ", reactor_id, " outside of configured unit count ", config.UnitCount))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
else
|
||||
-- try to establish the session
|
||||
local plc_id = svsessions.establish_plc_session(src_addr, i_seq_num, reactor_id, firmware_v)
|
||||
@@ -281,25 +282,25 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
println(util.c("PLC (", firmware_v, ") [@", src_addr, "] \xbb reactor ", reactor_id, " connected"))
|
||||
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
end
|
||||
end
|
||||
else
|
||||
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("invalid establish packet (on PLC channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
@@ -343,7 +344,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.info(util.c("dropping RTU establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.RTU then
|
||||
if packet.length == 4 then
|
||||
-- this is an RTU advertisement for a new session
|
||||
@@ -352,18 +353,18 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
|
||||
println(util.c("RTU (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug("RTU_ESTABLISH: packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on RTU channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("invalid establish packet (on RTU channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
@@ -397,7 +398,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.info(util.c("dropping coordinator establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.CRD then
|
||||
-- this is an attempt to establish a new coordinator session
|
||||
local s_id = svsessions.establish_crd_session(src_addr, i_seq_num, firmware_v)
|
||||
@@ -406,21 +407,21 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, facility.get_cooling_conf() })
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, facility.get_cooling_conf() })
|
||||
else
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on coordinator channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("CRD_ESTABLISH: establish packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
@@ -464,7 +465,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
log.info(util.c("dropping PDG establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
_send_establish(p_nic or c_nic, packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PKT then
|
||||
-- this is an attempt to establish a new pocket diagnostic session
|
||||
local s_id = svsessions.establish_pdg_session(src_addr, i_seq_num, firmware_v)
|
||||
@@ -472,14 +473,14 @@ function supervisor.comms(_version, nic, fp_ok, facility)
|
||||
println(util.c("PKT (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("PDG_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
_send_establish(p_nic or c_nic, packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on pocket channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(p_nic or c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("PDG_ESTABLISH: establish packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
_send_establish(p_nic or c_nic, packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
|
||||
Reference in New Issue