@@ -67,11 +67,10 @@ function logic.update_annunciator(self)
local plc_db = self.plc_i.get_db()
-- update ready state
-- - can't be tripped
-- - must have received status at least once
-- - must have received struct at least once
plc_ready = plc_db.formed and (not plc_db.no_reactor) and (not plc_db.rps_tripped) and
(next(self.plc_i.get_status()) ~= nil) and (next(self.plc_i.get_struct()) ~= nil)
-- - must be connected to a formed reactor
-- - can't have a tripped RPS
-- - must have received status, struct, and RPS status at least once
plc_ready = plc_db.formed and (not plc_db.no_reactor) and (not plc_db.rps_tripped) and self.plc_i.check_received_all_data()
-- update auto control limit
if (plc_db.mek_struct.max_burn > 0) and ((self.db.control.lim_br100 / 100) > plc_db.mek_struct.max_burn) then