#634 coordinator backplane interface

This commit is contained in:
Mikayla Fischler
2025-11-03 18:47:36 -05:00
parent 299c6bcf7a
commit 5abe687f69
5 changed files with 333 additions and 198 deletions

View File

@@ -29,11 +29,9 @@ local config = {}
coordinator.config = config
-- load the coordinator configuration<br>
-- status of 0 is OK, 1 is bad config, 2 is bad monitor config
---@return 0|1|2 status, nil|monitors_struct|string monitors (or error message)
-- load the coordinator configuration
function coordinator.load_config()
if not settings.load("/coordinator.settings") then return 1 end
if not settings.load("/coordinator.settings") then return false end
config.UnitCount = settings.get("UnitCount")
config.SpeakerVolume = settings.get("SpeakerVolume")
@@ -121,85 +119,7 @@ function coordinator.load_config()
cfv.assert_type_int(config.ColorMode)
cfv.assert_range(config.ColorMode, 1, themes.COLOR_MODE.NUM_MODES)
-- Monitor Setup
---@class monitors_struct
local monitors = {
main = nil, ---@type Monitor|nil
main_name = "",
flow = nil, ---@type Monitor|nil
flow_name = "",
unit_displays = {}, ---@type Monitor[]
unit_name_map = {} ---@type string[]
}
local mon_cfv = util.new_validator()
-- get all interface names
local names = {}
for iface, _ in pairs(ppm.get_monitor_list()) do table.insert(names, iface) end
local function setup_monitors()
mon_cfv.assert_type_str(config.MainDisplay)
if not config.DisableFlowView then mon_cfv.assert_type_str(config.FlowDisplay) end
mon_cfv.assert_eq(#config.UnitDisplays, config.UnitCount)
if mon_cfv.valid() then
local w, h, _
if not util.table_contains(names, config.MainDisplay) then
return 2, "Main monitor is not connected."
end
monitors.main = ppm.get_periph(config.MainDisplay)
monitors.main_name = config.MainDisplay
monitors.main.setTextScale(0.5)
w, _ = ppm.monitor_block_size(monitors.main.getSize())
if w ~= 8 then
return 2, util.c("Main monitor width is incorrect (was ", w, ", must be 8).")
end
if not config.DisableFlowView then
if not util.table_contains(names, config.FlowDisplay) then
return 2, "Flow monitor is not connected."
end
monitors.flow = ppm.get_periph(config.FlowDisplay)
monitors.flow_name = config.FlowDisplay
monitors.flow.setTextScale(0.5)
w, _ = ppm.monitor_block_size(monitors.flow.getSize())
if w ~= 8 then
return 2, util.c("Flow monitor width is incorrect (was ", w, ", must be 8).")
end
end
for i = 1, config.UnitCount do
local display = config.UnitDisplays[i]
if type(display) ~= "string" or not util.table_contains(names, display) then
return 2, "Unit " .. i .. " monitor is not connected."
end
monitors.unit_displays[i] = ppm.get_periph(display)
monitors.unit_name_map[i] = display
monitors.unit_displays[i].setTextScale(0.5)
w, h = ppm.monitor_block_size(monitors.unit_displays[i].getSize())
if w ~= 4 or h ~= 4 then
return 2, util.c("Unit ", i, " monitor size is incorrect (was ", w, " by ", h,", must be 4 by 4).")
end
end
else return 2, "Monitor configuration invalid." end
end
if cfv.valid() then
local ok, result, message = pcall(setup_monitors)
assert(ok, util.c("fatal error while trying to verify monitors: ", result))
if result == 2 then return 2, message end
else return 1 end
return 0, monitors
return cfv.valid()
end