#76 added trusted connection ranges for modem messages

This commit is contained in:
Mikayla Fischler
2023-02-07 17:31:22 -05:00
parent 1d3a1672c8
commit 6c09772a74
13 changed files with 109 additions and 62 deletions

View File

@@ -25,7 +25,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
local sps_rtu = require("rtu.dev.sps_rtu")
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
local RTU_VERSION = "beta-v0.9.13"
local RTU_VERSION = "beta-v0.10.0"
local rtu_t = types.rtu_t
@@ -42,6 +42,7 @@ local cfv = util.new_validator()
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
cfv.assert_type_table(config.RTU_DEVICES)
@@ -390,7 +391,8 @@ local function main()
log.debug("boot> conn watchdog started")
-- setup comms
smem_sys.rtu_comms = rtu.comms(RTU_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT, smem_sys.conn_watchdog)
smem_sys.rtu_comms = rtu.comms(RTU_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
config.TRUSTED_RANGE, smem_sys.conn_watchdog)
log.debug("boot> comms init")
-- init threads