#480 auxiliary coolant control logic
This commit is contained in:
@@ -92,7 +92,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
---@diagnostic disable-next-line: missing-fields
|
||||
valves = {}, ---@type unit_valves
|
||||
emcool_opened = false,
|
||||
em_cool_opened = false,
|
||||
aux_cool_opened = false,
|
||||
-- auto control
|
||||
auto_engaged = false,
|
||||
auto_idle = false,
|
||||
@@ -373,6 +374,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
local waste_po = _make_valve_iface(IO.WASTE_POPL)
|
||||
local waste_sps = _make_valve_iface(IO.WASTE_AM)
|
||||
local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
|
||||
local aux_cool = _make_valve_iface(IO.U_AUX_COOL)
|
||||
|
||||
---@class unit_valves
|
||||
self.valves = {
|
||||
@@ -380,7 +382,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
waste_sna = waste_sna,
|
||||
waste_po = waste_po,
|
||||
waste_sps = waste_sps,
|
||||
emer_cool = emer_cool
|
||||
emer_cool = emer_cool,
|
||||
aux_cool = aux_cool
|
||||
}
|
||||
|
||||
-- route reactor waste for a given waste product
|
||||
@@ -606,7 +609,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
if #self.redstone > 0 then
|
||||
logic.handle_redstone(self)
|
||||
elseif not self.plc_cache.rps_trip then
|
||||
self.emcool_opened = false
|
||||
self.em_cool_opened = false
|
||||
end
|
||||
end
|
||||
|
||||
@@ -724,7 +727,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
|
||||
-- queue a command to clear timeout/auto-scram if set
|
||||
function public.auto_cond_rps_reset()
|
||||
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then
|
||||
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.em_cool_opened) then
|
||||
local rps = self.plc_i.get_rps()
|
||||
if rps.timeout or rps.automatic then
|
||||
self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it
|
||||
@@ -865,7 +868,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
|
||||
-- check if emergency coolant activation has been tripped
|
||||
---@nodiscard
|
||||
function public.is_emer_cool_tripped() return self.emcool_opened end
|
||||
function public.is_emer_cool_tripped() return self.em_cool_opened end
|
||||
|
||||