#480 auxiliary coolant control logic
This commit is contained in:
@@ -728,7 +728,7 @@ function logic.update_status_text(self)
|
||||
self.status_text = { "RCS TRANSIENT", "check coolant system" }
|
||||
-- elseif is_active(self.alarms.RPSTransient) then
|
||||
-- RPS status handled when checking reactor status
|
||||
elseif self.emcool_opened then
|
||||
elseif self.em_cool_opened then
|
||||
self.status_text = { "EMERGENCY COOLANT OPENED", "reset RPS to close valve" }
|
||||
-- connection dependent states
|
||||
elseif self.plc_i ~= nil then
|
||||
@@ -886,7 +886,7 @@ function logic.handle_redstone(self)
|
||||
(annunc.CoolantLevelLow or (boiler_water_low and rps.ex_hcool)) and
|
||||
is_active(self.alarms.ReactorOverTemp))
|
||||
|
||||
if enable_emer_cool and not self.emcool_opened then
|
||||
if enable_emer_cool and not self.em_cool_opened then
|
||||
log.debug(util.c(">> Emergency Coolant Enable Detail Report (Unit ", self.r_id, ") <<"))
|
||||
log.debug(util.c("| CoolantLevelLow[", annunc.CoolantLevelLow, "] CoolantLevelLowLow[", rps.low_cool, "] ExcessHeatedCoolant[", rps.ex_hcool, "]"))
|
||||
log.debug(util.c("| ReactorOverTemp[", AISTATE_NAMES[self.alarms.ReactorOverTemp.state], "]"))
|
||||
@@ -910,13 +910,13 @@ function logic.handle_redstone(self)
|
||||
end
|
||||
end
|
||||
|
||||
if annunc.EmergencyCoolant > 1 and self.emcool_opened then
|
||||
if annunc.EmergencyCoolant > 1 and self.em_cool_opened then
|
||||
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve closed"))
|
||||
log.info(util.c("UNIT ", self.r_id, " turbines set to not dump steam"))
|
||||
end
|
||||
|
||||
self.emcool_opened = false
|
||||
elseif enable_emer_cool or self.emcool_opened then
|
||||
self.em_cool_opened = false
|
||||
elseif enable_emer_cool or self.em_cool_opened then
|
||||
-- set turbines to dump excess steam
|
||||
for i = 1, #self.turbines do
|
||||
local session = self.turbines[i]
|
||||
@@ -937,16 +937,33 @@ function logic.handle_redstone(self)
|
||||
end
|
||||
end
|
||||
|
||||
if annunc.EmergencyCoolant > 1 and not self.emcool_opened then
|
||||
if annunc.EmergencyCoolant > 1 and not self.em_cool_opened then
|
||||
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened"))
|
||||
log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam"))
|
||||
end
|
||||
|
||||
self.emcool_opened = true
|
||||
self.em_cool_opened = true
|
||||
end
|
||||
|
||||
-- set valve state always
|
||||
if self.emcool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end
|
||||
if self.em_cool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end
|
||||
|
||||
-----------------------
|
||||
-- Auxiliary Coolant --
|
||||
-----------------------
|
||||
|
||||
local enable_aux_cool = boiler_water_low or (annunc.CoolantLevelLow and self.num_boilers == 0)
|
||||
|
||||
if enable_aux_cool and not self.aux_cool_opened then
|
||||
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve opened"))
|
||||
self.aux_cool_opened = true
|
||||
elseif self.aux_cool_opened and self.turbine_flow_stable and not enable_aux_cool then
|
||||
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve closed"))
|
||||
self.aux_cool_opened = false
|
||||
end
|
||||
|
||||
-- set valve state always
|
||||
if self.aux_cool_opened then self.valves.aux_cool.open() else self.valves.aux_cool.close() end
|
||||
end
|
||||
|
||||
return logic
|
||||
|
||||