#589 initial attempt at reboot recovery
This commit is contained in:
@@ -5,6 +5,7 @@ local util = require("scada-common.util")
|
||||
local unit = require("supervisor.unit")
|
||||
local fac_update = require("supervisor.facility_update")
|
||||
|
||||
local plc = require("supervisor.session.plc")
|
||||
local rsctl = require("supervisor.session.rsctl")
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
@@ -31,6 +32,17 @@ local START_STATUS = {
|
||||
BLADE_MISMATCH = 2
|
||||
}
|
||||
|
||||
---@enum RECOVERY_STATE
|
||||
local RCV_STATE = {
|
||||
INACTIVE = 0,
|
||||
PRIMED = 1,
|
||||
RUNNING = 2,
|
||||
STOPPED = 3
|
||||
}
|
||||
|
||||
local CHARGE_SCALER = 1000000 -- convert MFE to FE
|
||||
local GEN_SCALER = 1000 -- convert kFE to FE
|
||||
|
||||
---@class facility_management
|
||||
local facility = {}
|
||||
|
||||
@@ -66,12 +78,15 @@ function facility.new(config)
|
||||
-- redstone I/O control
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
-- process control
|
||||
recovery = RCV_STATE.INACTIVE, ---@type RECOVERY_STATE
|
||||
recovery_boot_state = nil, ---@type sv_control_state|nil
|
||||
last_unit_states = nil, ---@type boolean[]
|
||||
units_ready = false,
|
||||
mode = PROCESS.INACTIVE,
|
||||
last_mode = PROCESS.INACTIVE,
|
||||
return_mode = PROCESS.INACTIVE,
|
||||
mode_set = PROCESS.MAX_BURN,
|
||||
start_fail = START_STATUS.OK,
|
||||
mode = PROCESS.INACTIVE, ---@type PROCESS
|
||||
last_mode = PROCESS.INACTIVE, ---@type PROCESS
|
||||
return_mode = PROCESS.INACTIVE, ---@type PROCESS
|
||||
mode_set = PROCESS.MAX_BURN, ---@type PROCESS
|
||||
start_fail = START_STATUS.OK, ---@type START_STATUS
|
||||
max_burn_combined = 0.0, -- maximum burn rate to clamp at
|
||||
burn_target = 0.1, -- burn rate target for aggregate burn mode
|
||||
charge_setpoint = 0, -- FE charge target setpoint
|
||||
@@ -101,8 +116,8 @@ function facility.new(config)
|
||||
last_error = 0.0,
|
||||
last_time = 0.0,
|
||||
-- waste processing
|
||||
waste_product = WASTE.PLUTONIUM,
|
||||
current_waste_product = WASTE.PLUTONIUM,
|
||||
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||
current_waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||
pu_fallback = false,
|
||||
sps_low_power = false,
|
||||
disabled_sps = false,
|
||||
@@ -126,14 +141,16 @@ function facility.new(config)
|
||||
imtx_faulted_times = { 0, 0, 0 }
|
||||
}
|
||||
|
||||
--#region SETUP
|
||||
|
||||
-- provide self to facility update functions
|
||||
local f_update = fac_update(self)
|
||||
|
||||
-- create units
|
||||
for i = 1, config.UnitCount do
|
||||
table.insert(self.units,
|
||||
unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.units, unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.group_map, AUTO_GROUP.MANUAL)
|
||||
table.insert(self.last_unit_states, false)
|
||||
end
|
||||
|
||||
-- list for RTU session management
|
||||
@@ -149,6 +166,62 @@ function facility.new(config)
|
||||
table.insert(self.test_tone_states, false)
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
---@param auto_cfg start_auto_config configuration
|
||||
---@return boolean ready, number[] unit_limits
|
||||
local function _auto_check_and_save(auto_cfg)
|
||||
local ready = false
|
||||
|
||||
-- load up current limits
|
||||
local limits = {}
|
||||
for i = 1, config.UnitCount do
|
||||
limits[i] = self.units[i].get_control_inf().lim_br100 * 100
|
||||
end
|
||||
|
||||
-- only allow changes if not running
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = auto_cfg.mode
|
||||
end
|
||||
|
||||
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
|
||||
self.burn_target = auto_cfg.burn_target
|
||||
end
|
||||
|
||||
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
|
||||
self.charge_setpoint = auto_cfg.charge_target * CHARGE_SCALER
|
||||
end
|
||||
|
||||
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = auto_cfg.gen_target * GEN_SCALER
|
||||
end
|
||||
|
||||
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
|
||||
for i = 1, config.UnitCount do
|
||||
local limit = auto_cfg.limits[i]
|
||||
|
||||
if (type(limit) == "number") and (limit >= 0.1) then
|
||||
limits[i] = limit
|
||||
self.units[i].set_burn_limit(limit)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
ready = self.mode_set > 0
|
||||
|
||||
if ((self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0)) or
|
||||
((self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0)) or
|
||||
((self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1)) then
|
||||
ready = false
|
||||
end
|
||||
end
|
||||
|
||||
return ready, limits
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
---@class facility
|
||||
@@ -239,6 +312,42 @@ function facility.new(config)
|
||||
|
||||
-- update (iterate) the facility management
|
||||
function public.update()
|
||||
-- attempt reboot recovery if in progress
|
||||
if self.recovery == RCV_STATE.RUNNING then
|
||||
-- try to start auto control
|
||||
if self.recovery_boot_state.mode ~= nil and self.units_ready then
|
||||
self.recovery_boot_state.mode = nil
|
||||
self.mode = self.mode_set
|
||||
log.info("FAC: process startup resume initiated")
|
||||
end
|
||||
|
||||
local recovered = self.recovery_boot_state.mode == nil
|
||||
|
||||
-- restore manual control reactors
|
||||
for i = 1, #self.units do
|
||||
if self.recovery_boot_state.unit_states[i] and self.group_map[i] == AUTO_GROUP.MANUAL then
|
||||
recovered = false
|
||||
|
||||
if self.units[i].get_control_inf().ready then
|
||||
local plc_s = svsessions.get_reactor_session(i)
|
||||
if plc_s ~= nil then
|
||||
plc_s.in_queue.push_command(plc.PLC_S_CMDS.ENABLE)
|
||||
log.info("FAC: startup resume enabling manually controlled reactor unit #" .. i)
|
||||
|
||||
-- only execute once
|
||||
self.recovery_boot_state.unit_states[i] = nil
|
||||
end
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
if recovered then
|
||||
self.recovery = RCV_STATE.STOPPED
|
||||
self.recovery_boot_state = nil
|
||||
log.info("FAC: startup resume complete")
|
||||
end
|
||||
end
|
||||
|
||||
-- run process control and evaluate automatic SCRAM
|
||||
f_update.pre_auto()
|
||||
f_update.auto_control(config.ExtChargeIdling)
|
||||
@@ -267,6 +376,35 @@ function facility.new(config)
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Startup Recovery
|
||||
|
||||
---@param state sv_control_state
|
||||
function public.startup_recovery_init(state)
|
||||
if self.recovery == RCV_STATE.INACTIVE then
|
||||
self.recovery_boot_state = state
|
||||
self.recovery = RCV_STATE.PRIMED
|
||||
end
|
||||
end
|
||||
|
||||
-- attempt startup recovery
|
||||
---@param auto_cfg start_auto_config configuration
|
||||
function public.startup_recovery_start(auto_cfg)
|
||||
if self.recovery == RCV_STATE.PRIMED and self.recovery_boot_state and
|
||||
self.recovery_boot_state.mode ~= PROCESS.INACTIVE and self.recovery_boot_state.mode ~= PROCESS.SYSTEM_ALARM_IDLE then
|
||||
self.recovery = util.trinary(_auto_check_and_save(auto_cfg), RCV_STATE.RUNNING, RCV_STATE.STOPPED)
|
||||
log.info(util.c("FAC: startup resume ", util.trinary(self.recovery == RCV_STATE.RUNNING, "ready", "failed")))
|
||||
else self.recovery = RCV_STATE.STOPPED end
|
||||
end
|
||||
|
||||
-- used on certain coordinator commands to end reboot recovery (remain in current operational state)
|
||||
function public.cancel_recovery()
|
||||
self.recovery = RCV_STATE.STOPPED
|
||||
self.recovery_boot_state = nil
|
||||
log.info("FAC: process startup resume cancelled by user operation")
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Commands
|
||||
|
||||
-- SCRAM all reactor units
|
||||
@@ -290,59 +428,13 @@ function facility.new(config)
|
||||
function public.auto_stop() self.mode = PROCESS.INACTIVE end
|
||||
|
||||
-- set automatic control configuration and start the process
|
||||
---@param auto_cfg sys_auto_config configuration
|
||||
---@param auto_cfg start_auto_config configuration
|
||||
---@return table response ready state (successfully started) and current configuration (after updating)
|
||||
function public.auto_start(auto_cfg)
|
||||
local charge_scaler = 1000000 -- convert MFE to FE
|
||||
local gen_scaler = 1000 -- convert kFE to FE
|
||||
local ready = false
|
||||
local ready, limits = _auto_check_and_save(auto_cfg)
|
||||
|
||||
-- load up current limits
|
||||
local limits = {}
|
||||
for i = 1, config.UnitCount do
|
||||
limits[i] = self.units[i].get_control_inf().lim_br100 * 100
|
||||
end
|
||||
|
||||
-- only allow changes if not running
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = auto_cfg.mode
|
||||
end
|
||||
|
||||
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
|
||||
self.burn_target = auto_cfg.burn_target
|
||||
end
|
||||
|
||||
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
|
||||
self.charge_setpoint = auto_cfg.charge_target * charge_scaler
|
||||
end
|
||||
|
||||
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = auto_cfg.gen_target * gen_scaler
|
||||
end
|
||||
|
||||
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
|
||||
for i = 1, config.UnitCount do
|
||||
local limit = auto_cfg.limits[i]
|
||||
|
||||
if (type(limit) == "number") and (limit >= 0.1) then
|
||||
limits[i] = limit
|
||||
self.units[i].set_burn_limit(limit)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
ready = self.mode_set > 0
|
||||
|
||||
if ((self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0)) or
|
||||
((self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0)) or
|
||||
((self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1)) then
|
||||
ready = false
|
||||
end
|
||||
|
||||
ready = ready and self.units_ready
|
||||
|
||||
if ready then self.mode = self.mode_set end
|
||||
if ready and self.units_ready then
|
||||
self.mode = self.mode_set
|
||||
end
|
||||
|
||||
log.debug(util.c("FAC: process start ", util.trinary(ready, "accepted", "rejected")))
|
||||
@@ -351,8 +443,8 @@ function facility.new(config)
|
||||
ready,
|
||||
self.mode_set,
|
||||
self.burn_target,
|
||||
self.charge_setpoint / charge_scaler,
|
||||
self.gen_rate_setpoint / gen_scaler,
|
||||
self.charge_setpoint / CHARGE_SCALER,
|
||||
self.gen_rate_setpoint / GEN_SCALER,
|
||||
limits
|
||||
}
|
||||
end
|
||||
|
||||
Reference in New Issue
Block a user