#95 added boiler/turbine RTUs to supervisor, tons of RTU/MODBUS related bugfixes, adjusted annunciator conditions
This commit is contained in:
@@ -70,6 +70,7 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
in_q = mqueue.new(),
|
||||
has_build = false,
|
||||
periodics = {
|
||||
next_formed_req = 0,
|
||||
next_build_req = 0,
|
||||
next_state_req = 0,
|
||||
next_tanks_req = 0
|
||||
@@ -81,8 +82,8 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
length = 0,
|
||||
width = 0,
|
||||
height = 0,
|
||||
min_pos = 0,
|
||||
max_pos = 0,
|
||||
min_pos = { x = 0, y = 0, z = 0 }, ---@type coordinate
|
||||
max_pos = { x = 0, y = 0, z = 0 }, ---@type coordinate
|
||||
blades = 0,
|
||||
coils = 0,
|
||||
vents = 0,
|
||||
@@ -101,7 +102,7 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
dumping_mode = DUMPING_MODE.IDLE ---@type DUMPING_MODE
|
||||
},
|
||||
tanks = {
|
||||
steam = 0,
|
||||
steam = { type = "mekanism:empty_gas", amount = 0 }, ---@type tank_fluid
|
||||
steam_need = 0,
|
||||
steam_fill = 0.0,
|
||||
energy = 0,
|
||||
@@ -163,9 +164,17 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
-- handle a packet
|
||||
---@param m_pkt modbus_frame
|
||||
function public.handle_packet(m_pkt)
|
||||
local txn_type = self.session.try_resolve(m_pkt.txn_id)
|
||||
local txn_type = self.session.try_resolve(m_pkt)
|
||||
if txn_type == false then
|
||||
-- nothing to do
|
||||
elseif txn_type == TXN_TYPES.FORMED then
|
||||
-- formed response
|
||||
-- load in data if correct length
|
||||
if m_pkt.length == 1 then
|
||||
self.db.formed = m_pkt.data[1]
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (" .. TXN_TAGS[txn_type] .. ")")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.BUILD then
|
||||
-- build response
|
||||
if m_pkt.length == 15 then
|
||||
|
||||