#172 fixed bug with full builds not being sent

This commit is contained in:
Mikayla Fischler
2023-02-20 14:50:20 -05:00
parent 8df67245c5
commit e2d2a0f1dc
8 changed files with 63 additions and 25 deletions

View File

@@ -71,11 +71,13 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
},
-- when to next retry one of these messages
retry_times = {
builds_packet = 0,
f_builds_packet = 0,
u_builds_packet = 0
},
-- message acknowledgements
acks = {
builds = false,
fac_builds = false,
unit_builds = false
}
@@ -115,16 +117,25 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
self.seq_num = self.seq_num + 1
end
-- send both facility and unit builds
local function _send_all_builds()
local unit_builds = {}
for i = 1, #self.units do
local unit = self.units[i] ---@type reactor_unit
unit_builds[unit.get_id()] = unit.get_build()
end
_send(SCADA_CRDN_TYPES.INITIAL_BUILDS, { facility.get_build(), unit_builds })
end
-- send facility builds
local function _send_fac_builds()
self.acks.fac_builds = false
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build() })
end
-- send unit builds
local function _send_unit_builds()
self.acks.unit_builds = false
local builds = {}
for i = 1, #self.units do
@@ -206,7 +217,10 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_CRDN then
if pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
if pkt.type == SCADA_CRDN_TYPES.INITIAL_BUILDS then
-- acknowledgement to coordinator receiving builds
self.acks.builds = true
elseif pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
-- acknowledgement to coordinator receiving builds
self.acks.fac_builds = true
elseif pkt.type == SCADA_CRDN_TYPES.FAC_CMD then
@@ -450,6 +464,13 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
-- builds packet retries
if not self.acks.builds then
if rtimes.builds_packet - util.time() <= 0 then
_send_all_builds()
rtimes.builds_packet = util.time() + RETRY_PERIOD
end
end
if not self.acks.fac_builds then
if rtimes.f_builds_packet - util.time() <= 0 then
_send_fac_builds()