#172 fixed bug with full builds not being sent
This commit is contained in:
@@ -71,11 +71,13 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
},
|
||||
-- when to next retry one of these messages
|
||||
retry_times = {
|
||||
builds_packet = 0,
|
||||
f_builds_packet = 0,
|
||||
u_builds_packet = 0
|
||||
},
|
||||
-- message acknowledgements
|
||||
acks = {
|
||||
builds = false,
|
||||
fac_builds = false,
|
||||
unit_builds = false
|
||||
}
|
||||
@@ -115,16 +117,25 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send both facility and unit builds
|
||||
local function _send_all_builds()
|
||||
local unit_builds = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
unit_builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.INITIAL_BUILDS, { facility.get_build(), unit_builds })
|
||||
end
|
||||
|
||||
-- send facility builds
|
||||
local function _send_fac_builds()
|
||||
self.acks.fac_builds = false
|
||||
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build() })
|
||||
end
|
||||
|
||||
-- send unit builds
|
||||
local function _send_unit_builds()
|
||||
self.acks.unit_builds = false
|
||||
|
||||
local builds = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
@@ -206,7 +217,10 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_CRDN then
|
||||
if pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
|
||||
if pkt.type == SCADA_CRDN_TYPES.INITIAL_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.builds = true
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.fac_builds = true
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.FAC_CMD then
|
||||
@@ -450,6 +464,13 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
|
||||
-- builds packet retries
|
||||
|
||||
if not self.acks.builds then
|
||||
if rtimes.builds_packet - util.time() <= 0 then
|
||||
_send_all_builds()
|
||||
rtimes.builds_packet = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
|
||||
if not self.acks.fac_builds then
|
||||
if rtimes.f_builds_packet - util.time() <= 0 then
|
||||
_send_fac_builds()
|
||||
|
||||