#362 taking max of connected radiation monitors
This commit is contained in:
@@ -87,7 +87,6 @@ local changes = {}
|
||||
|
||||
local RTU_DEV_TYPES = { "boilerValve", "turbineValve", "dynamicValve", "inductionPort", "spsPort", "solarNeutronActivator", "environmentDetector" }
|
||||
local NEEDS_UNIT = { "boilerValve", "turbineValve", "dynamicValve", "solarNeutronActivator", "environmentDetector" }
|
||||
local NEEDS_IDX = { "boilerValve", "turbineValve", "dynamicValve" }
|
||||
|
||||
---@class rtu_configurator
|
||||
local configurator = {}
|
||||
@@ -732,8 +731,10 @@ local function config_view(display)
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("Each reactor unit can have at most 1 tank and the facility can have at most 4. Each facility tank must have a unique # 1 through 4, regardless of where it is connected. Only a total of 4 tanks can be displayed on the flow monitor.")
|
||||
elseif type == "environmentDetector" then
|
||||
tool_ctl.p_idx.hide()
|
||||
tool_ctl.p_prompt.set_value("This will be an environment detector for...")
|
||||
tool_ctl.p_prompt.set_value("This is the # environment detector for...")
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(99)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then tool_ctl.p_unit.disable() else tool_ctl.p_unit.enable() end
|
||||
tool_ctl.p_assign_btn.show()
|
||||
@@ -741,12 +742,12 @@ local function config_view(display)
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility, in which case the maximum radiation reading from those assigned to that particular unit or the facility will be used.")
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility. In that case, the maximum radiation reading from those assigned to that particular unit or the facility will be used for alarms and display.")
|
||||
elseif type == "inductionPort" or type == "spsPort" then
|
||||
local dev = util.trinary(type == "inductionPort", "induction matrix", "SPS")
|
||||
tool_ctl.p_idx.hide(true)
|
||||
tool_ctl.p_unit.hide(true)
|
||||
tool_ctl.p_prompt.set_value("This will be the " .. dev .. " for the facility.")
|
||||
tool_ctl.p_prompt.set_value("This is the " .. dev .. " for the facility.")
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
@@ -815,11 +816,13 @@ local function config_view(display)
|
||||
function tool_ctl.p_assign(opt)
|
||||
if opt == 1 then
|
||||
tool_ctl.p_unit.disable()
|
||||
tool_ctl.p_idx.enable()
|
||||
if new_peri_attrs[2] == "dynamicValve" then tool_ctl.p_idx.enable() end
|
||||
else
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_idx.set_value(1)
|
||||
tool_ctl.p_idx.disable()
|
||||
if new_peri_attrs[2] == "dynamicValve" then
|
||||
tool_ctl.p_idx.set_value(1)
|
||||
tool_ctl.p_idx.disable()
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
@@ -879,6 +882,12 @@ local function config_view(display)
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else index = idx end
|
||||
elseif peri_type == "environmentDetector" then
|
||||
if not (util.is_int(idx) and idx > 0) then
|
||||
tool_ctl.p_err.set_value("Index must be greater than 0.")
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else index = idx end
|
||||
end
|
||||
|
||||
tool_ctl.p_err.hide(true)
|
||||
|
||||
Reference in New Issue
Block a user