#367 reworked ownership of tank data and facility instance to make more sense

This commit is contained in:
Mikayla Fischler
2024-08-20 21:32:54 -04:00
parent 4775639245
commit fc7441b2f6
6 changed files with 63 additions and 52 deletions

View File

@@ -2,11 +2,11 @@ local log = require("scada-common.log")
local types = require("scada-common.types")
local util = require("scada-common.util")
local unit = require("supervisor.unit")
local fac_update = require("supervisor.facility_update")
local unit = require("supervisor.unit")
local rsctl = require("supervisor.session.rsctl")
local svsessions = require("supervisor.session.svsessions")
local PROCESS = types.PROCESS
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
@@ -35,9 +35,7 @@ local facility = {}
-- create a new facility management object
---@nodiscard
---@param config svr_config supervisor configuration
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
function facility.new(config, cooling_conf, check_rtu_id)
function facility.new(config)
---@class _facility_self
local self = {
units = {},
@@ -46,8 +44,13 @@ function facility.new(config, cooling_conf, check_rtu_id)
all_sys_ok = false,
allow_testing = false,
-- facility tanks
tank_defs = cooling_conf.fac_tank_defs,
tank_list = {},
---@class sv_cooling_conf
cooling_conf = {
r_cool = config.CoolingConfig,
fac_tank_mode = config.FacilityTankMode,
fac_tank_defs = config.FacilityTankDefs,
fac_tank_list = {}
},
-- rtus
rtu_conn_count = 0,
rtu_list = {},
@@ -124,7 +127,8 @@ function facility.new(config, cooling_conf, check_rtu_id)
-- create units
for i = 1, config.UnitCount do
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, check_rtu_id, config.ExtChargeIdling))
table.insert(self.units,
unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
table.insert(self.group_map, 0)
end
@@ -143,26 +147,28 @@ function facility.new(config, cooling_conf, check_rtu_id)
--#region decode tank configuration
local cool_conf = self.cooling_conf
-- determine tank information
if cooling_conf.fac_tank_mode == 0 then
self.tank_defs = {}
if cool_conf.fac_tank_mode == 0 then
cool_conf.tank_defs = {}
-- on facility tank mode 0, setup tank defs to match unit tank option
for i = 1, config.UnitCount do
self.tank_defs[i] = util.trinary(cooling_conf.r_cool[i].TankConnection, 1, 0)
cool_conf.tank_defs[i] = util.trinary(cool_conf.r_cool[i].TankConnection, 1, 0)
end
self.tank_list = { table.unpack(self.tank_defs) }
cool_conf.tank_list = { table.unpack(cool_conf.tank_defs) }
else
-- decode the layout of tanks from the connections definitions
local tank_mode = cooling_conf.fac_tank_mode
local tank_defs = self.tank_defs
local tank_mode = cool_conf.fac_tank_mode
local tank_defs = cool_conf.fac_tank_defs
local tank_list = { table.unpack(tank_defs) }
local function calc_fdef(start_idx, end_idx)
local first = 4
for i = start_idx, end_idx do
if self.tank_defs[i] == 2 then
if tank_defs[i] == 2 then
if i < first then first = i end
end
end
@@ -227,7 +233,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
end
end
self.tank_list = tank_list
cool_conf.fac_tank_list = tank_list
end
--#endregion
@@ -247,7 +253,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
---@param imatrix unit_session
---@return boolean linked induction matrix accepted (max 1)
function public.add_imatrix(imatrix)
local fail_code, fail_str = check_rtu_id(imatrix, self.induction, 1)
local fail_code, fail_str = svsessions.check_rtu_id(imatrix, self.induction, 1)
if fail_code == 0 then
table.insert(self.induction, imatrix)
@@ -262,7 +268,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
---@param sps unit_session
---@return boolean linked SPS accepted (max 1)
function public.add_sps(sps)
local fail_code, fail_str = check_rtu_id(sps, self.sps, 1)
local fail_code, fail_str = svsessions.check_rtu_id(sps, self.sps, 1)
if fail_code == 0 then
table.insert(self.sps, sps)
@@ -303,7 +309,7 @@ function facility.new(config, cooling_conf, check_rtu_id)
f_update.redstone(public.ack_all)
-- unit tasks
f_update.unit_mgmt(cooling_conf)
f_update.unit_mgmt()
-- update alarm tones
f_update.alarm_audio()
@@ -631,6 +637,9 @@ function facility.new(config, cooling_conf, check_rtu_id)
---@param rtu_sessions table session list of all connected RTUs
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
-- get the facility cooling configuration
function public.get_cooling_conf() return self.cooling_conf end
-- get the units in this facility
---@nodiscard
function public.get_units() return self.units end