#8 cleaned up closing logic, added connected flags to RTU unit sessions
This commit is contained in:
@@ -202,6 +202,12 @@ plc.new_session = function (id, for_reactor, in_queue, out_queue)
|
||||
self.sDB.mek_struct.max_burn = mek_data[8]
|
||||
end
|
||||
|
||||
-- mark this PLC session as closed, stop watchdog
|
||||
local _close = function ()
|
||||
self.rtu_conn_watchdog.cancel()
|
||||
self.connected = false
|
||||
end
|
||||
|
||||
-- send an RPLC packet
|
||||
---@param msg_type RPLC_TYPES
|
||||
---@param msg table
|
||||
@@ -392,7 +398,7 @@ plc.new_session = function (id, for_reactor, in_queue, out_queue)
|
||||
end
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
|
||||
-- close the session
|
||||
self.connected = false
|
||||
_close()
|
||||
else
|
||||
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
||||
end
|
||||
@@ -427,13 +433,12 @@ plc.new_session = function (id, for_reactor, in_queue, out_queue)
|
||||
|
||||
-- check if a timer matches this session's watchdog
|
||||
public.check_wd = function (timer)
|
||||
return self.plc_conn_watchdog.is_timer(timer)
|
||||
return self.plc_conn_watchdog.is_timer(timer) and self.connected
|
||||
end
|
||||
|
||||
-- close the connection
|
||||
public.close = function ()
|
||||
self.plc_conn_watchdog.cancel()
|
||||
self.connected = false
|
||||
_close()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
|
||||
println("connection to reactor " .. self.for_reactor .. " PLC closed by server")
|
||||
log.info(log_header .. "session closed by server")
|
||||
@@ -506,7 +511,6 @@ plc.new_session = function (id, for_reactor, in_queue, out_queue)
|
||||
|
||||
-- exit if connection was closed
|
||||
if not self.connected then
|
||||
self.plc_conn_watchdog.cancel()
|
||||
println("connection to reactor " .. self.for_reactor .. " PLC closed by remote host")
|
||||
log.info(log_header .. "session closed by remote host")
|
||||
return self.connected
|
||||
|
||||
Reference in New Issue
Block a user