supervisor comms init
This commit is contained in:
@@ -5,14 +5,12 @@
|
||||
-- instant failover if active goes offline without re-sync
|
||||
SYSTEM_TYPE = 'active'
|
||||
|
||||
-- scada network
|
||||
SCADA_NET_PFX = 16000
|
||||
-- scada network listen for PLC's and RTU's
|
||||
SCADA_DEV_LISTEN = 16000
|
||||
-- failover synchronization
|
||||
SCADA_FO_CHANNEL = 16001
|
||||
-- listen port for SCADA supervisor access
|
||||
-- listen port for SCADA supervisor access by coordinators
|
||||
SCADA_SV_CHANNEL = 16002
|
||||
-- listen port for PLC's
|
||||
SCADA_PLC_LISTEN = 16003
|
||||
|
||||
-- expected number of reactors
|
||||
NUM_REACTORS = 4
|
||||
|
||||
@@ -20,14 +20,24 @@ if modem == nil then
|
||||
return
|
||||
end
|
||||
|
||||
-- read config
|
||||
|
||||
-- start comms
|
||||
if not modem.isOpen(config.LISTEN_PORT) then
|
||||
modem.open(config.LISTEN_PORT)
|
||||
-- determine active/backup mode
|
||||
local mode = comms.SCADA_SV_MODES.BACKUP
|
||||
if config.SYSTEM_TYPE == "active" then
|
||||
mode = comms.SCADA_SV_MODES.ACTIVE
|
||||
end
|
||||
|
||||
local comms = comms.superv_comms(config.NUM_REACTORS, modem, config.SCADA_PLC_LISTEN, config.SCADA_SV_CHANNEL)
|
||||
-- start comms, open all channels
|
||||
if not modem.isOpen(config.SCADA_DEV_LISTEN) then
|
||||
modem.open(config.SCADA_DEV_LISTEN)
|
||||
end
|
||||
if not modem.isOpen(config.SCADA_FO_CHANNEL) then
|
||||
modem.open(config.SCADA_FO_CHANNEL)
|
||||
end
|
||||
if not modem.isOpen(config.SCADA_SV_CHANNEL) then
|
||||
modem.open(config.SCADA_SV_CHANNEL)
|
||||
end
|
||||
|
||||
local comms = comms.superv_comms(config.NUM_REACTORS, modem, config.SCADA_DEV_LISTEN, config.SCADA_FO_CHANNEL, config.SCADA_SV_CHANNEL)
|
||||
|
||||
-- base loop clock (4Hz, 5 ticks)
|
||||
local loop_tick = os.startTimer(0.25)
|
||||
|
||||
Reference in New Issue