@@ -9,12 +9,8 @@ local turbinev_rtu = {}
|
||||
function turbinev_rtu.new(turbine)
|
||||
local unit = rtu.init_unit(turbine)
|
||||
|
||||
-- disable auto fault clearing
|
||||
turbine.__p_clear_fault()
|
||||
turbine.__p_disable_afc()
|
||||
|
||||
-- discrete inputs --
|
||||
unit.connect_di(turbine.isFormed)
|
||||
unit.connect_di("isFormed")
|
||||
|
||||
-- coils --
|
||||
unit.connect_coil(function () turbine.incrementDumpingMode() end, function () end)
|
||||
@@ -22,44 +18,39 @@ function turbinev_rtu.new(turbine)
|
||||
|
||||
-- input registers --
|
||||
-- multiblock properties
|
||||
unit.connect_input_reg(turbine.getLength)
|
||||
unit.connect_input_reg(turbine.getWidth)
|
||||
unit.connect_input_reg(turbine.getHeight)
|
||||
unit.connect_input_reg(turbine.getMinPos)
|
||||
unit.connect_input_reg(turbine.getMaxPos)
|
||||
unit.connect_input_reg("getLength")
|
||||
unit.connect_input_reg("getWidth")
|
||||
unit.connect_input_reg("getHeight")
|
||||
unit.connect_input_reg("getMinPos")
|
||||
unit.connect_input_reg("getMaxPos")
|
||||
-- build properties
|
||||
unit.connect_input_reg(turbine.getBlades)
|
||||
unit.connect_input_reg(turbine.getCoils)
|
||||
unit.connect_input_reg(turbine.getVents)
|
||||
unit.connect_input_reg(turbine.getDispersers)
|
||||
unit.connect_input_reg(turbine.getCondensers)
|
||||
unit.connect_input_reg(turbine.getSteamCapacity)
|
||||
unit.connect_input_reg(turbine.getMaxEnergy)
|
||||
unit.connect_input_reg(turbine.getMaxFlowRate)
|
||||
unit.connect_input_reg(turbine.getMaxProduction)
|
||||
unit.connect_input_reg(turbine.getMaxWaterOutput)
|
||||
unit.connect_input_reg("getBlades")
|
||||
unit.connect_input_reg("getCoils")
|
||||
unit.connect_input_reg("getVents")
|
||||
unit.connect_input_reg("getDispersers")
|
||||
unit.connect_input_reg("getCondensers")
|
||||
unit.connect_input_reg("getSteamCapacity")
|
||||
unit.connect_input_reg("getMaxEnergy")
|
||||
unit.connect_input_reg("getMaxFlowRate")
|
||||
unit.connect_input_reg("getMaxProduction")
|
||||
unit.connect_input_reg("getMaxWaterOutput")
|
||||
-- current state
|
||||
unit.connect_input_reg(turbine.getFlowRate)
|
||||
unit.connect_input_reg(turbine.getProductionRate)
|
||||
unit.connect_input_reg(turbine.getLastSteamInputRate)
|
||||
unit.connect_input_reg(turbine.getDumpingMode)
|
||||
unit.connect_input_reg("getFlowRate")
|
||||
unit.connect_input_reg("getProductionRate")
|
||||
unit.connect_input_reg("getLastSteamInputRate")
|
||||
unit.connect_input_reg("getDumpingMode")
|
||||
-- tanks/containers
|
||||
unit.connect_input_reg(turbine.getSteam)
|
||||
unit.connect_input_reg(turbine.getSteamNeeded)
|
||||
unit.connect_input_reg(turbine.getSteamFilledPercentage)
|
||||
unit.connect_input_reg(turbine.getEnergy)
|
||||
unit.connect_input_reg(turbine.getEnergyNeeded)
|
||||
unit.connect_input_reg(turbine.getEnergyFilledPercentage)
|
||||
unit.connect_input_reg("getSteam")
|
||||
unit.connect_input_reg("getSteamNeeded")
|
||||
unit.connect_input_reg("getSteamFilledPercentage")
|
||||
unit.connect_input_reg("getEnergy")
|
||||
unit.connect_input_reg("getEnergyNeeded")
|
||||
unit.connect_input_reg("getEnergyFilledPercentage")
|
||||
|
||||
-- holding registers --
|
||||
unit.connect_holding_reg(turbine.getDumpingMode, turbine.setDumpingMode)
|
||||
unit.connect_holding_reg("getDumpingMode", "setDumpingMode")
|
||||
|
||||
-- check if any calls faulted
|
||||
local faulted = turbine.__p_is_faulted()
|
||||
turbine.__p_clear_fault()
|
||||
turbine.__p_enable_afc()
|
||||
|
||||
return unit.interface(), faulted
|
||||
return unit.interface(), false
|
||||
end
|
||||
|
||||
return turbinev_rtu
|
||||
|
||||
Reference in New Issue