#434 #454 PPM improvements and undefined function overhaul

This commit is contained in:
Mikayla Fischler
2024-03-23 00:26:58 -04:00
parent 1c0f61b3e0
commit 19869416af
12 changed files with 186 additions and 265 deletions

View File

@@ -9,12 +9,8 @@ local turbinev_rtu = {}
function turbinev_rtu.new(turbine)
local unit = rtu.init_unit(turbine)
-- disable auto fault clearing
turbine.__p_clear_fault()
turbine.__p_disable_afc()
-- discrete inputs --
unit.connect_di(turbine.isFormed)
unit.connect_di("isFormed")
-- coils --
unit.connect_coil(function () turbine.incrementDumpingMode() end, function () end)
@@ -22,44 +18,39 @@ function turbinev_rtu.new(turbine)
-- input registers --
-- multiblock properties
unit.connect_input_reg(turbine.getLength)
unit.connect_input_reg(turbine.getWidth)
unit.connect_input_reg(turbine.getHeight)
unit.connect_input_reg(turbine.getMinPos)
unit.connect_input_reg(turbine.getMaxPos)
unit.connect_input_reg("getLength")
unit.connect_input_reg("getWidth")
unit.connect_input_reg("getHeight")
unit.connect_input_reg("getMinPos")
unit.connect_input_reg("getMaxPos")
-- build properties
unit.connect_input_reg(turbine.getBlades)
unit.connect_input_reg(turbine.getCoils)
unit.connect_input_reg(turbine.getVents)
unit.connect_input_reg(turbine.getDispersers)
unit.connect_input_reg(turbine.getCondensers)
unit.connect_input_reg(turbine.getSteamCapacity)
unit.connect_input_reg(turbine.getMaxEnergy)
unit.connect_input_reg(turbine.getMaxFlowRate)
unit.connect_input_reg(turbine.getMaxProduction)
unit.connect_input_reg(turbine.getMaxWaterOutput)
unit.connect_input_reg("getBlades")
unit.connect_input_reg("getCoils")
unit.connect_input_reg("getVents")
unit.connect_input_reg("getDispersers")
unit.connect_input_reg("getCondensers")
unit.connect_input_reg("getSteamCapacity")
unit.connect_input_reg("getMaxEnergy")
unit.connect_input_reg("getMaxFlowRate")
unit.connect_input_reg("getMaxProduction")
unit.connect_input_reg("getMaxWaterOutput")
-- current state
unit.connect_input_reg(turbine.getFlowRate)
unit.connect_input_reg(turbine.getProductionRate)
unit.connect_input_reg(turbine.getLastSteamInputRate)
unit.connect_input_reg(turbine.getDumpingMode)
unit.connect_input_reg("getFlowRate")
unit.connect_input_reg("getProductionRate")
unit.connect_input_reg("getLastSteamInputRate")
unit.connect_input_reg("getDumpingMode")
-- tanks/containers
unit.connect_input_reg(turbine.getSteam)
unit.connect_input_reg(turbine.getSteamNeeded)
unit.connect_input_reg(turbine.getSteamFilledPercentage)
unit.connect_input_reg(turbine.getEnergy)
unit.connect_input_reg(turbine.getEnergyNeeded)
unit.connect_input_reg(turbine.getEnergyFilledPercentage)
unit.connect_input_reg("getSteam")
unit.connect_input_reg("getSteamNeeded")
unit.connect_input_reg("getSteamFilledPercentage")
unit.connect_input_reg("getEnergy")
unit.connect_input_reg("getEnergyNeeded")
unit.connect_input_reg("getEnergyFilledPercentage")
-- holding registers --
unit.connect_holding_reg(turbine.getDumpingMode, turbine.setDumpingMode)
unit.connect_holding_reg("getDumpingMode", "setDumpingMode")
-- check if any calls faulted
local faulted = turbine.__p_is_faulted()
turbine.__p_clear_fault()
turbine.__p_enable_afc()
return unit.interface(), faulted
return unit.interface(), false
end
return turbinev_rtu