This commit is contained in:
@@ -12,13 +12,14 @@ local PROCESS = types.PROCESS
|
||||
-- 2856 FE per blade per 1 mB, 285.6 FE per blade per 0.1 mB (minimum)
|
||||
local POWER_PER_BLADE = util.joules_to_fe(7140)
|
||||
|
||||
local MAX_CHARGE = 0.99
|
||||
local HIGH_CHARGE = 1.0
|
||||
local RE_ENABLE_CHARGE = 0.95
|
||||
|
||||
local AUTO_SCRAM = {
|
||||
NONE = 0,
|
||||
MATRIX_DC = 1,
|
||||
MATRIX_FILL = 2
|
||||
MATRIX_FILL = 2,
|
||||
CRIT_ALARM = 3
|
||||
}
|
||||
|
||||
local charge_Kp = 1.0
|
||||
@@ -46,6 +47,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
units_ready = false,
|
||||
mode = PROCESS.INACTIVE,
|
||||
last_mode = PROCESS.INACTIVE,
|
||||
return_mode = PROCESS.INACTIVE,
|
||||
mode_set = PROCESS.SIMPLE,
|
||||
max_burn_combined = 0.0, -- maximum burn rate to clamp at
|
||||
burn_target = 0.1, -- burn rate target for aggregate burn mode
|
||||
@@ -53,6 +55,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
gen_rate_target = 0, -- FE/t charge rate target
|
||||
group_map = { 0, 0, 0, 0 }, -- units -> group IDs
|
||||
prio_defs = { {}, {}, {}, {} }, -- priority definitions (each level is a table of units)
|
||||
at_max_burn = false,
|
||||
ascram = false,
|
||||
ascram_reason = AUTO_SCRAM.NONE,
|
||||
-- closed loop control
|
||||
@@ -102,6 +105,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- split a burn rate among the reactors
|
||||
---@param burn_rate number burn rate assignment
|
||||
---@param ramp boolean true to ramp, false to set right away
|
||||
---@return integer unallocated
|
||||
local function _allocate_burn_rate(burn_rate, ramp)
|
||||
local unallocated = math.floor(burn_rate * 10)
|
||||
|
||||
@@ -117,32 +121,38 @@ function facility.new(num_reactors, cooling_conf)
|
||||
splits[#units] = splits[#units] + (unallocated % #units)
|
||||
|
||||
-- go through all reactor units in this group
|
||||
for u = 1, #units do
|
||||
local ctl = units[u].get_control_inf() ---@type unit_control
|
||||
for id = 1, #units do
|
||||
local u = units[id] ---@type reactor_unit
|
||||
|
||||
local ctl = u.get_control_inf()
|
||||
local lim_br10 = u.a_get_effective_limit()
|
||||
|
||||
local last = ctl.br10
|
||||
|
||||
if splits[u] <= ctl.lim_br10 then
|
||||
ctl.br10 = splits[u]
|
||||
if splits[id] <= lim_br10 then
|
||||
ctl.br10 = splits[id]
|
||||
else
|
||||
ctl.br10 = ctl.lim_br10
|
||||
ctl.br10 = lim_br10
|
||||
|
||||
if u < #units then
|
||||
local remaining = #units - u
|
||||
if id < #units then
|
||||
local remaining = #units - id
|
||||
split = math.floor(unallocated / remaining)
|
||||
for x = (u + 1), #units do splits[x] = split end
|
||||
for x = (id + 1), #units do splits[x] = split end
|
||||
splits[#units] = splits[#units] + (unallocated % remaining)
|
||||
end
|
||||
end
|
||||
|
||||
unallocated = unallocated - ctl.br10
|
||||
unallocated = math.max(0, unallocated - ctl.br10)
|
||||
|
||||
if last ~= ctl.br10 then units[u].a_commit_br10(ramp) end
|
||||
if last ~= ctl.br10 then
|
||||
log.debug("unit " .. id .. ": set to " .. ctl.br10 .. " (was " .. last .. ")")
|
||||
u.a_commit_br10(ramp)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- stop if fully allocated
|
||||
if unallocated <= 0 then break end
|
||||
end
|
||||
|
||||
return unallocated
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
@@ -215,10 +225,18 @@ function facility.new(num_reactors, cooling_conf)
|
||||
local now = util.time_s()
|
||||
|
||||
local state_changed = self.mode ~= self.last_mode
|
||||
local next_mode = self.mode
|
||||
|
||||
-- once auto control is started, sort the priority sublists by limits
|
||||
if state_changed then
|
||||
self.saturated = false
|
||||
|
||||
log.debug("FAC: state changed from " .. self.last_mode .. " to " .. self.mode)
|
||||
|
||||
if self.last_mode == PROCESS.INACTIVE then
|
||||
---@todo change this to be a reset button
|
||||
if self.mode ~= PROCESS.MATRIX_FAULT_IDLE then self.ascram = false end
|
||||
|
||||
local blade_count = 0
|
||||
self.max_burn_combined = 0.0
|
||||
|
||||
@@ -259,27 +277,31 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.initial_ramp = false
|
||||
end
|
||||
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
-- check if we are ready to start when that time comes
|
||||
self.units_ready = true
|
||||
for i = 1, #self.prio_defs do
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
self.units_ready = self.units_ready and u.get_control_inf().ready
|
||||
end
|
||||
-- update unit ready state
|
||||
self.units_ready = true
|
||||
for i = 1, #self.prio_defs do
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
self.units_ready = self.units_ready and u.get_control_inf().ready
|
||||
end
|
||||
end
|
||||
|
||||
-- perform mode-specific operations
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if self.units_ready then
|
||||
self.status_text = { "IDLE", "control disengaged" }
|
||||
else
|
||||
self.status_text = { "NOT READY", "assigned units not ready" }
|
||||
end
|
||||
elseif self.mode == PROCESS.SIMPLE then
|
||||
-- run units at their last configured set point
|
||||
-- run units at their limits
|
||||
if state_changed then
|
||||
self.time_start = now
|
||||
---@todo will still need to ramp?
|
||||
self.saturated = true
|
||||
self.status_text = { "MONITORED MODE", "running reactors at limit" }
|
||||
log.debug(util.c("FAC: SIMPLE mode first call completed"))
|
||||
end
|
||||
|
||||
_allocate_burn_rate(self.max_burn_combined, true)
|
||||
elseif self.mode == PROCESS.BURN_RATE then
|
||||
-- a total aggregate burn rate
|
||||
if state_changed then
|
||||
@@ -294,7 +316,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
|
||||
if not self.waiting_on_ramp then
|
||||
_allocate_burn_rate(self.burn_target, self.initial_ramp)
|
||||
local unallocated = _allocate_burn_rate(self.burn_target, true)
|
||||
self.saturated = self.burn_target == self.max_burn_combined or unallocated > 0
|
||||
|
||||
if self.initial_ramp then
|
||||
self.status_text = { "BURN RATE MODE", "ramping reactors" }
|
||||
@@ -397,16 +420,27 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
_allocate_burn_rate(sp_c, false)
|
||||
end
|
||||
elseif self.mode == PROCESS.MATRIX_FAULT_IDLE then
|
||||
-- exceeded charge, wait until condition clears
|
||||
if self.ascram_reason == AUTO_SCRAM.NONE then
|
||||
next_mode = self.return_mode
|
||||
log.info("FAC: exiting matrix fault idle state due to fault resolution")
|
||||
elseif self.ascram_reason == AUTO_SCRAM.CRIT_ALARM then
|
||||
next_mode = PROCESS.INACTIVE
|
||||
log.info("FAC: exiting matrix fault idle state due to critical unit alarm")
|
||||
end
|
||||
elseif self.mode == PROCESS.UNIT_ALARM_IDLE then
|
||||
-- do nothing, wait for user to confirm (stop and reset)
|
||||
elseif self.mode ~= PROCESS.INACTIVE then
|
||||
log.error(util.c("FAC: unsupported process mode ", self.mode, ", switching to inactive"))
|
||||
self.mode = PROCESS.INACTIVE
|
||||
next_mode = PROCESS.INACTIVE
|
||||
end
|
||||
|
||||
------------------------------
|
||||
-- Evaluate Automatic SCRAM --
|
||||
------------------------------
|
||||
|
||||
if self.mode ~= PROCESS.INACTIVE then
|
||||
if (self.mode ~= PROCESS.INACTIVE) and (self.mode ~= PROCESS.UNIT_ALARM_IDLE) then
|
||||
local scram = false
|
||||
|
||||
if self.induction[1] ~= nil then
|
||||
@@ -415,37 +449,93 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
if self.ascram_reason == AUTO_SCRAM.MATRIX_DC then
|
||||
self.ascram_reason = AUTO_SCRAM.NONE
|
||||
log.info("FAC: cleared automatic SCRAM trip due to prior induction matrix disconnect")
|
||||
end
|
||||
|
||||
if (db.tanks.energy_fill > MAX_CHARGE) or
|
||||
if (db.tanks.energy_fill >= HIGH_CHARGE) or
|
||||
(self.ascram_reason == AUTO_SCRAM.MATRIX_FILL and db.tanks.energy_fill > RE_ENABLE_CHARGE) then
|
||||
scram = true
|
||||
|
||||
if self.mode ~= PROCESS.MATRIX_FAULT_IDLE then
|
||||
self.return_mode = self.mode
|
||||
next_mode = PROCESS.MATRIX_FAULT_IDLE
|
||||
end
|
||||
|
||||
if self.ascram_reason == AUTO_SCRAM.NONE then
|
||||
self.ascram_reason = AUTO_SCRAM.MATRIX_FILL
|
||||
end
|
||||
elseif self.ascram_reason == AUTO_SCRAM.MATRIX_FILL then
|
||||
log.info("FAC: charge state of induction matrix entered acceptable range <= " .. (RE_ENABLE_CHARGE * 100) .. "%")
|
||||
self.ascram_reason = AUTO_SCRAM.NONE
|
||||
end
|
||||
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
|
||||
if u.has_critical_alarm() then
|
||||
scram = true
|
||||
|
||||
if self.ascram_reason == AUTO_SCRAM.NONE then
|
||||
self.ascram_reason = AUTO_SCRAM.CRIT_ALARM
|
||||
end
|
||||
|
||||
next_mode = PROCESS.UNIT_ALARM_IDLE
|
||||
|
||||
log.info("FAC: emergency exit of process control due to critical unit alarm")
|
||||
break
|
||||
end
|
||||
end
|
||||
else
|
||||
scram = true
|
||||
|
||||
if self.mode ~= PROCESS.MATRIX_FAULT_IDLE then
|
||||
self.return_mode = self.mode
|
||||
next_mode = PROCESS.MATRIX_FAULT_IDLE
|
||||
end
|
||||
|
||||
if self.ascram_reason == AUTO_SCRAM.NONE then
|
||||
self.ascram_reason = AUTO_SCRAM.MATRIX_DC
|
||||
end
|
||||
end
|
||||
|
||||
-- SCRAM all units
|
||||
if not self.ascram and scram then
|
||||
if (not self.ascram) and scram then
|
||||
for i = 1, #self.prio_defs do
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
u.a_scram()
|
||||
end
|
||||
end
|
||||
|
||||
self.ascram = true
|
||||
if self.ascram_reason == AUTO_SCRAM.MATRIX_DC then
|
||||
log.info("FAC: automatic SCRAM due to induction matrix disconnection")
|
||||
self.status_text = { "AUTOMATIC SCRAM", "induction matrix disconnected" }
|
||||
elseif self.ascram_reason == AUTO_SCRAM.MATRIX_FILL then
|
||||
log.info("FAC: automatic SCRAM due to induction matrix high charge")
|
||||
self.status_text = { "AUTOMATIC SCRAM", "induction matrix fill high" }
|
||||
elseif self.ascram_reason == AUTO_SCRAM.CRIT_ALARM then
|
||||
log.info("FAC: automatic SCRAM due to critical unit alarm")
|
||||
self.status_text = { "AUTOMATIC SCRAM", "critical unit alarm tripped" }
|
||||
else
|
||||
log.error(util.c("FAC: automatic SCRAM reason (", self.ascram_reason, ") not set to a known value"))
|
||||
end
|
||||
end
|
||||
|
||||
self.ascram = scram
|
||||
|
||||
-- clear PLC SCRAM if we should
|
||||
if not self.ascram then
|
||||
self.ascram_reason = AUTO_SCRAM.NONE
|
||||
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
u.a_cond_rps_reset()
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- update last mode
|
||||
-- update last mode and set next mode
|
||||
self.last_mode = self.mode
|
||||
self.mode = next_mode
|
||||
end
|
||||
|
||||
-- call the update function of all units in the facility
|
||||
@@ -580,6 +670,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.units_ready,
|
||||
self.mode,
|
||||
self.waiting_on_ramp,
|
||||
self.at_max_burn or self.saturated,
|
||||
self.ascram,
|
||||
self.status_text[1],
|
||||
self.status_text[2],
|
||||
|
||||
Reference in New Issue