reworked computed status logic and handle dynamic tank data
This commit is contained in:
@@ -196,8 +196,6 @@ function iocontrol.init_fac(conf)
|
||||
local entry = {
|
||||
unit_id = i,
|
||||
connected = false,
|
||||
---@type { boilers: { connected: boolean, faulted: boolean }[], turbines: { connected: boolean, faulted: boolean }[] }
|
||||
rtu_hw = {},
|
||||
|
||||
num_boilers = 0,
|
||||
num_turbines = 0,
|
||||
|
||||
105
pocket/iorx.lua
105
pocket/iorx.lua
@@ -9,6 +9,10 @@ local util = require("scada-common.util")
|
||||
local ALARM = types.ALARM
|
||||
local ALARM_STATE = types.ALARM_STATE
|
||||
|
||||
local BLR_STATE = types.BOILER_STATE
|
||||
local TRB_STATE = types.TURBINE_STATE
|
||||
local TNK_STATE = types.TANK_STATE
|
||||
|
||||
local io ---@type pocket_ioctl
|
||||
local iorx = {} ---@class iorx
|
||||
|
||||
@@ -61,10 +65,12 @@ function iorx.record_unit_data(data)
|
||||
local unit = io.units[data[1]]
|
||||
|
||||
unit.connected = data[2]
|
||||
unit.rtu_hw = data[3]
|
||||
local comp_statuses = data[3]
|
||||
unit.a_group = data[4]
|
||||
unit.alarms = data[5]
|
||||
|
||||
local next_c_stat = 1
|
||||
|
||||
unit.unit_ps.publish("auto_group_id", unit.a_group)
|
||||
unit.unit_ps.publish("auto_group", types.AUTO_GROUP_NAMES[unit.a_group + 1])
|
||||
|
||||
@@ -152,43 +158,27 @@ function iorx.record_unit_data(data)
|
||||
|
||||
local control_status = 1
|
||||
local reactor_status = 1
|
||||
local reactor_state = 1
|
||||
local rps_status = 1
|
||||
|
||||
if unit.connected then
|
||||
-- update RPS status
|
||||
if unit.reactor_data.rps_tripped then
|
||||
control_status = 2
|
||||
|
||||
if unit.reactor_data.rps_trip_cause == "manual" then
|
||||
reactor_state = 4 -- disabled
|
||||
rps_status = 3
|
||||
else
|
||||
reactor_state = 6 -- SCRAM
|
||||
rps_status = 2
|
||||
end
|
||||
rps_status = util.trinary(unit.reactor_data.rps_trip_cause == "manual", 3, 2)
|
||||
else
|
||||
rps_status = 4
|
||||
reactor_state = 4
|
||||
end
|
||||
|
||||
reactor_status = 4 -- ok, until proven otherwise
|
||||
|
||||
-- update reactor/control status
|
||||
if unit.reactor_data.mek_status.status then
|
||||
reactor_status = 4
|
||||
reactor_state = 5 -- running
|
||||
control_status = util.trinary(unit.annunciator.AutoControl, 4, 3)
|
||||
else
|
||||
if unit.reactor_data.no_reactor then
|
||||
reactor_status = 2
|
||||
reactor_state = 3 -- faulted
|
||||
elseif not unit.reactor_data.formed then
|
||||
elseif (not unit.reactor_data.formed) or unit.reactor_data.rps_status.force_dis then
|
||||
reactor_status = 3
|
||||
reactor_state = 2 -- not formed
|
||||
elseif unit.reactor_data.rps_status.force_dis then
|
||||
reactor_status = 3
|
||||
reactor_state = 7 -- force disabled
|
||||
else
|
||||
reactor_status = 4
|
||||
end
|
||||
end
|
||||
|
||||
@@ -213,9 +203,11 @@ function iorx.record_unit_data(data)
|
||||
|
||||
unit.unit_ps.publish("U_ControlStatus", control_status)
|
||||
unit.unit_ps.publish("U_ReactorStatus", reactor_status)
|
||||
unit.unit_ps.publish("U_ReactorStateStatus", reactor_state)
|
||||
unit.unit_ps.publish("U_ReactorStateStatus", comp_statuses[next_c_stat])
|
||||
unit.unit_ps.publish("U_RPS", rps_status)
|
||||
|
||||
next_c_stat = next_c_stat + 1
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region RTU Devices
|
||||
@@ -225,32 +217,26 @@ function iorx.record_unit_data(data)
|
||||
for id = 1, #unit.boiler_data_tbl do
|
||||
local boiler = unit.boiler_data_tbl[id]
|
||||
local ps = unit.boiler_ps_tbl[id]
|
||||
local c_stat = comp_statuses[next_c_stat]
|
||||
|
||||
local boiler_status = 1
|
||||
local computed_status = 1
|
||||
|
||||
if unit.rtu_hw.boilers[id].connected then
|
||||
if unit.rtu_hw.boilers[id].faulted then
|
||||
if c_stat ~= BLR_STATE.OFFLINE then
|
||||
if c_stat == BLR_STATE.FAULT then
|
||||
boiler_status = 3
|
||||
computed_status = 3
|
||||
elseif boiler.formed then
|
||||
elseif c_stat ~= BLR_STATE.UNFORMED then
|
||||
boiler_status = 4
|
||||
|
||||
if boiler.state.boil_rate > 0 then
|
||||
computed_status = 5
|
||||
else
|
||||
computed_status = 4
|
||||
end
|
||||
else
|
||||
boiler_status = 2
|
||||
computed_status = 2
|
||||
end
|
||||
|
||||
_record_multiblock_status(unit.rtu_hw.boilers[id].faulted, boiler, ps)
|
||||
_record_multiblock_status(c_stat == BLR_STATE.FAULT, boiler, ps)
|
||||
end
|
||||
|
||||
ps.publish("BoilerStatus", boiler_status)
|
||||
ps.publish("BoilerStateStatus", computed_status)
|
||||
ps.publish("BoilerStateStatus", c_stat)
|
||||
|
||||
next_c_stat = next_c_stat + 1
|
||||
end
|
||||
|
||||
unit.turbine_data_tbl = data[9]
|
||||
@@ -258,38 +244,55 @@ function iorx.record_unit_data(data)
|
||||
for id = 1, #unit.turbine_data_tbl do
|
||||
local turbine = unit.turbine_data_tbl[id]
|
||||
local ps = unit.turbine_ps_tbl[id]
|
||||
local c_stat = comp_statuses[next_c_stat]
|
||||
|
||||
local turbine_status = 1
|
||||
local computed_status = 1
|
||||
|
||||
if unit.rtu_hw.turbines[id].connected then
|
||||
if unit.rtu_hw.turbines[id].faulted then
|
||||
if c_stat ~= TRB_STATE.OFFLINE then
|
||||
if c_stat == TRB_STATE.FAULT then
|
||||
turbine_status = 3
|
||||
computed_status = 3
|
||||
elseif turbine.formed then
|
||||
turbine_status = 4
|
||||
|
||||
if turbine.tanks.energy_fill >= 0.99 then
|
||||
computed_status = 6
|
||||
elseif turbine.state.flow_rate < 100 then
|
||||
computed_status = 4
|
||||
else
|
||||
computed_status = 5
|
||||
end
|
||||
else
|
||||
turbine_status = 2
|
||||
computed_status = 2
|
||||
end
|
||||
|
||||
_record_multiblock_status(unit.rtu_hw.turbines[id].faulted, turbine, ps)
|
||||
_record_multiblock_status(c_stat == TRB_STATE.FAULT, turbine, ps)
|
||||
end
|
||||
|
||||
ps.publish("TurbineStatus", turbine_status)
|
||||
ps.publish("TurbineStateStatus", computed_status)
|
||||
ps.publish("TurbineStateStatus", c_stat)
|
||||
|
||||
next_c_stat = next_c_stat + 1
|
||||
end
|
||||
|
||||
unit.tank_data_tbl = data[10]
|
||||
|
||||
for id = 1, #unit.tank_data_tbl do
|
||||
local tank = unit.tank_data_tbl[id]
|
||||
local ps = unit.tank_ps_tbl[id]
|
||||
local c_stat = comp_statuses[next_c_stat]
|
||||
|
||||
local tank_status = 1
|
||||
|
||||
if c_stat ~= TNK_STATE.OFFLINE then
|
||||
if c_stat == TNK_STATE.FAULT then
|
||||
tank_status = 3
|
||||
elseif tank.formed then
|
||||
tank_status = 4
|
||||
else
|
||||
tank_status = 2
|
||||
end
|
||||
|
||||
_record_multiblock_status(c_stat == TNK_STATE.FAULT, tank, ps)
|
||||
end
|
||||
|
||||
ps.publish("DynamicTankStatus", tank_status)
|
||||
ps.publish("DynamicTankStateStatus", c_stat)
|
||||
|
||||
next_c_stat = next_c_stat + 1
|
||||
end
|
||||
|
||||
unit.last_rate_change_ms = data[11]
|
||||
unit.turbine_flow_stable = data[12]
|
||||
|
||||
|
||||
Reference in New Issue