@@ -40,8 +40,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
units = {},
|
||||
induction = {},
|
||||
redstone = {},
|
||||
status_text = { "IDLE", "control inactive" },
|
||||
status_text = { "START UP", "initializing..." },
|
||||
-- process control
|
||||
units_ready = false,
|
||||
mode = PROCESS.INACTIVE,
|
||||
last_mode = PROCESS.INACTIVE,
|
||||
mode_set = PROCESS.SIMPLE,
|
||||
@@ -234,7 +235,10 @@ function facility.new(num_reactors, cooling_conf)
|
||||
log.debug(util.c("FAC: starting auto control: chg_conv = ", self.charge_conversion, ", blade_count = ", blade_count, ", max_burn = ", self.max_burn_combined))
|
||||
elseif self.mode == PROCESS.INACTIVE then
|
||||
for i = 1, #self.prio_defs do
|
||||
-- SCRAM reactors and disengage auto control
|
||||
-- use manual SCRAM since inactive was requested, and automatic SCRAM trips an alarm
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
u.scram()
|
||||
u.a_disengage()
|
||||
end
|
||||
end
|
||||
@@ -249,7 +253,21 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.initial_ramp = false
|
||||
end
|
||||
|
||||
if self.mode == PROCESS.SIMPLE then
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
-- check if we are ready to start when that time comes
|
||||
self.units_ready = true
|
||||
for i = 1, #self.prio_defs do
|
||||
for _, u in pairs(self.prio_defs[i]) do
|
||||
self.units_ready = self.units_ready and u.get_control_inf().ready
|
||||
end
|
||||
end
|
||||
|
||||
if self.units_ready then
|
||||
self.status_text = { "IDLE", "control disengaged" }
|
||||
else
|
||||
self.status_text = { "NOT READY", "assigned units not ready" }
|
||||
end
|
||||
elseif self.mode == PROCESS.SIMPLE then
|
||||
-- run units at their last configured set point
|
||||
if state_changed then
|
||||
self.time_start = now
|
||||
@@ -504,6 +522,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
ready = false
|
||||
end
|
||||
|
||||
ready = ready and self.units_ready
|
||||
|
||||
if ready then self.mode = self.mode_set end
|
||||
end
|
||||
|
||||
@@ -550,6 +570,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- get automatic process control status
|
||||
function public.get_control_status()
|
||||
return {
|
||||
self.units_ready,
|
||||
self.mode,
|
||||
self.waiting_on_ramp,
|
||||
self.ascram,
|
||||
|
||||
Reference in New Issue