@@ -174,6 +174,8 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- fields for facility control
|
||||
---@class unit_control
|
||||
control = {
|
||||
ready = false,
|
||||
degraded = false,
|
||||
blade_count = 0,
|
||||
br10 = 0,
|
||||
lim_br10 = 0
|
||||
@@ -398,7 +400,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_set_burn(self.db.control.br10 / 10, ramp)
|
||||
|
||||
if ramp then self.ramp_target_br10 = self.db.control.br10 / 10 end
|
||||
if ramp then self.ramp_target_br10 = self.db.control.br10 end
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -407,8 +409,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
---@return boolean complete
|
||||
function public.a_ramp_complete()
|
||||
if self.plc_i ~= nil then
|
||||
return (math.floor(self.plc_i.get_db().mek_status.burn_rate * 10) == self.ramp_target_br10) or (self.ramp_target_br10 == 0)
|
||||
else return false end
|
||||
local cur_rate = math.floor(self.plc_i.get_db().mek_status.burn_rate * 10)
|
||||
return (cur_rate == self.ramp_target_br10) or (self.ramp_target_br10 == 0)
|
||||
else return true end
|
||||
end
|
||||
|
||||
-- perform an automatic SCRAM
|
||||
@@ -428,6 +431,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
if self.plc_s ~= nil and not self.plc_s.open then
|
||||
self.plc_s = nil
|
||||
self.plc_i = nil
|
||||
self.db.control.br10 = 0
|
||||
self.db.control.lim_br10 = 0
|
||||
end
|
||||
|
||||
@@ -436,6 +440,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
_unlink_disconnected_units(self.turbines)
|
||||
_unlink_disconnected_units(self.redstone)
|
||||
|
||||
-- update degraded state for auto control
|
||||
self.db.control.degraded = (#self.boilers ~= num_boilers) or (#self.turbines ~= num_turbines) or (self.plc_i == nil)
|
||||
|
||||
-- update deltas
|
||||
_dt__compute_all()
|
||||
|
||||
@@ -606,9 +613,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- get information required for automatic reactor control
|
||||
function public.get_control_inf() return self.db.control end
|
||||
|
||||
-- get unit state (currently only waste mode)
|
||||
-- get unit state
|
||||
function public.get_state()
|
||||
return { self.status_text[1], self.status_text[2], self.waste_mode }
|
||||
return { self.status_text[1], self.status_text[2], self.waste_mode, self.db.control.ready, self.db.control.degraded }
|
||||
end
|
||||
|
||||
-- get the reactor ID
|
||||
|
||||
Reference in New Issue