@@ -38,9 +38,17 @@ function logic.update_annunciator(self)
|
||||
-- check PLC status
|
||||
self.db.annunciator.PLCOnline = self.plc_i ~= nil
|
||||
|
||||
local plc_ready = self.db.annunciator.PLCOnline
|
||||
|
||||
if self.db.annunciator.PLCOnline then
|
||||
local plc_db = self.plc_i.get_db()
|
||||
|
||||
-- update ready state
|
||||
-- - can't be tripped
|
||||
-- - must have received status at least once
|
||||
-- - must have received struct at least once
|
||||
plc_ready = (not plc_db.rps_tripped) and (plc_db.last_status_update > 0) and (plc_db.mek_struct.length > 0)
|
||||
|
||||
-- update auto control limit
|
||||
if (self.db.control.lim_br10 == 0) or ((self.db.control.lim_br10 / 10) > plc_db.mek_struct.max_burn) then
|
||||
self.db.control.lim_br10 = math.floor(plc_db.mek_struct.max_burn * 10)
|
||||
@@ -106,6 +114,8 @@ function logic.update_annunciator(self)
|
||||
-- BOILERS --
|
||||
-------------
|
||||
|
||||
local boilers_ready = num_boilers == #self.boilers
|
||||
|
||||
-- clear boiler online flags
|
||||
for i = 1, num_boilers do self.db.annunciator.BoilerOnline[i] = false end
|
||||
|
||||
@@ -119,6 +129,14 @@ function logic.update_annunciator(self)
|
||||
local session = self.boilers[i] ---@type unit_session
|
||||
local boiler = session.get_db() ---@type boilerv_session_db
|
||||
|
||||
-- update ready state
|
||||
-- - must be formed
|
||||
-- - must have received build, state, and tanks at least once
|
||||
boilers_ready = boilers_ready and boiler.formed and
|
||||
(boiler.build.last_update > 0) and
|
||||
(boiler.state.last_update > 0) and
|
||||
(boiler.tanks.last_update > 0)
|
||||
|
||||
total_boil_rate = total_boil_rate + boiler.state.boil_rate
|
||||
boiler_steam_dt_sum = _get_dt(DT_KEYS.BoilerSteam .. self.boilers[i].get_device_idx())
|
||||
boiler_water_dt_sum = _get_dt(DT_KEYS.BoilerWater .. self.boilers[i].get_device_idx())
|
||||
@@ -185,6 +203,8 @@ function logic.update_annunciator(self)
|
||||
-- TURBINES --
|
||||
--------------
|
||||
|
||||
local turbines_ready = num_turbines == #self.turbines
|
||||
|
||||
-- clear turbine online flags
|
||||
for i = 1, num_turbines do self.db.annunciator.TurbineOnline[i] = false end
|
||||
|
||||
@@ -201,6 +221,14 @@ function logic.update_annunciator(self)
|
||||
local session = self.turbines[i] ---@type unit_session
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
|
||||
-- update ready state
|
||||
-- - must be formed
|
||||
-- - must have received build, state, and tanks at least once
|
||||
turbines_ready = turbines_ready and turbine.formed and
|
||||
(turbine.build.last_update > 0) and
|
||||
(turbine.state.last_update > 0) and
|
||||
(turbine.tanks.last_update > 0)
|
||||
|
||||
total_flow_rate = total_flow_rate + turbine.state.flow_rate
|
||||
total_input_rate = total_input_rate + turbine.state.steam_input_rate
|
||||
max_water_return_rate = max_water_return_rate + turbine.build.max_water_output
|
||||
@@ -257,6 +285,9 @@ function logic.update_annunciator(self)
|
||||
local has_steam = db.state.steam_input_rate > 0 or db.tanks.steam_fill > 0.01
|
||||
self.db.annunciator.TurbineTrip[turbine.get_device_idx()] = has_steam and db.state.flow_rate == 0
|
||||
end
|
||||
|
||||
-- update auto control ready state for this unit
|
||||
self.db.control.ready = plc_ready and boilers_ready and turbines_ready
|
||||
end
|
||||
|
||||
-- update an alarm state given conditions
|
||||
|
||||
Reference in New Issue