@@ -125,7 +125,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
if self.plc_s ~= nil then
|
||||
local plc_db = self.plc_i.get_db()
|
||||
|
||||
-- @todo Meknaism 10.1+ will change fuel/waste to need _amnt
|
||||
---@todo Mekanism 10.1+ will change fuel/waste to need _amnt
|
||||
_compute_dt(DT_KEYS.ReactorTemp, plc_db.mek_status.temp)
|
||||
_compute_dt(DT_KEYS.ReactorFuel, plc_db.mek_status.fuel)
|
||||
_compute_dt(DT_KEYS.ReactorWaste, plc_db.mek_status.waste)
|
||||
@@ -137,7 +137,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local db = boiler.get_db() ---@type boiler_session_db
|
||||
|
||||
-- @todo Meknaism 10.1+ will change water/steam to need .amount
|
||||
---@todo Mekanism 10.1+ will change water/steam to need .amount
|
||||
_compute_dt(DT_KEYS.BoilerWater .. boiler.get_device_idx(), db.tanks.water)
|
||||
_compute_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx(), db.tanks.steam)
|
||||
_compute_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx(), db.tanks.ccool.amount)
|
||||
@@ -149,7 +149,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
local db = turbine.get_db() ---@type turbine_session_db
|
||||
|
||||
_compute_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx(), db.tanks.steam)
|
||||
-- @todo Mekanism 10.1+ needed
|
||||
---@todo Mekanism 10.1+ needed
|
||||
-- _compute_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx(), db.?)
|
||||
end
|
||||
end
|
||||
@@ -176,16 +176,16 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
end
|
||||
|
||||
-- update other annunciator fields
|
||||
self.db.annunciator.ReactorSCRAM = plc_db.overridden
|
||||
self.db.annunciator.ReactorSCRAM = plc_db.rps_tripped
|
||||
self.db.annunciator.ManualReactorSCRAM = plc_db.rps_trip_cause == types.rps_status_t.manual
|
||||
self.db.annunciator.RCPTrip = plc_db.rps_tripped and (plc_db.rps_status.ex_hcool or plc_db.rps_status.no_cool)
|
||||
self.db.annunciator.RCSFlowLow = plc_db.mek_status.ccool_fill < 0.75 or plc_db.mek_status.hcool_fill > 0.25
|
||||
self.db.annunciator.ReactorTempHigh = plc_db.mek_status.temp > 1000
|
||||
self.db.annunciator.ReactorHighDeltaT = _get_dt(DT_KEYS.ReactorTemp) > 100
|
||||
self.db.annunciator.FuelInputRateLow = _get_dt(DT_KEYS.ReactorFuel) < 0.0 or plc_db.mek_status.fuel_fill <= 0.01
|
||||
-- @todo this is catagorized as not urgent, but the >= 0.99 is extremely urgent, revist this (RPS will kick in though)
|
||||
---@todo this is catagorized as not urgent, but the >= 0.99 is extremely urgent, revist this (RPS will kick in though)
|
||||
self.db.annunciator.WasteLineOcclusion = _get_dt(DT_KEYS.ReactorWaste) > 0.0 or plc_db.mek_status.waste_fill >= 0.99
|
||||
-- @todo this is dependent on setup, i.e. how much coolant is buffered and the turbine setup
|
||||
---@todo this is dependent on setup, i.e. how much coolant is buffered and the turbine setup
|
||||
self.db.annunciator.HighStartupRate = not plc_db.control_state and plc_db.mek_status.burn_rate > 40
|
||||
end
|
||||
|
||||
|
||||