code cleanup, type hints, bugfixes, and #98 removal of support for mek 10.0 RTU peripherals
This commit is contained in:
16
rtu/rtu.lua
16
rtu/rtu.lua
@@ -1,15 +1,12 @@
|
||||
local comms = require("scada-common.comms")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local log = require("scada-common.log")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
local comms = require("scada-common.comms")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local modbus = require("rtu.modbus")
|
||||
|
||||
local rtu = {}
|
||||
|
||||
local rtu_t = types.rtu_t
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
@@ -333,6 +330,7 @@ function rtu.comms(version, modem, local_port, server_port, conn_watchdog)
|
||||
|
||||
if protocol == PROTOCOLS.MODBUS_TCP then
|
||||
local return_code = false
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
local reply = modbus.reply__neg_ack(packet)
|
||||
|
||||
-- handle MODBUS instruction
|
||||
@@ -342,17 +340,20 @@ function rtu.comms(version, modem, local_port, server_port, conn_watchdog)
|
||||
|
||||
if unit.name == "redstone_io" then
|
||||
-- immediately execute redstone RTU requests
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
return_code, reply = unit.modbus_io.handle_packet(packet)
|
||||
if not return_code then
|
||||
log.warning("requested MODBUS operation failed" .. unit_dbg_tag)
|
||||
end
|
||||
else
|
||||
-- check validity then pass off to unit comms thread
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
return_code, reply = unit.modbus_io.check_request(packet)
|
||||
if return_code then
|
||||
-- check if there are more than 3 active transactions
|
||||
-- still queue the packet, but this may indicate a problem
|
||||
if unit.pkt_queue.length() > 3 then
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
reply = modbus.reply__srv_device_busy(packet)
|
||||
log.debug("queueing new request with " .. unit.pkt_queue.length() ..
|
||||
" transactions already in the queue" .. unit_dbg_tag)
|
||||
@@ -366,6 +367,7 @@ function rtu.comms(version, modem, local_port, server_port, conn_watchdog)
|
||||
end
|
||||
else
|
||||
-- unit ID out of range?
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
reply = modbus.reply__gw_unavailable(packet)
|
||||
log.error("received MODBUS packet for non-existent unit")
|
||||
end
|
||||
|
||||