code cleanup, type hints, bugfixes, and #98 removal of support for mek 10.0 RTU peripherals
This commit is contained in:
@@ -57,6 +57,15 @@ local SCADA_CRDN_TYPES = {
|
||||
ALARM = 4 -- alarm signaling
|
||||
}
|
||||
|
||||
---@alias CRDN_COMMANDS integer
|
||||
local CRDN_COMMANDS = {
|
||||
SCRAM = 0, -- SCRAM the reactor
|
||||
START = 1, -- start the reactor
|
||||
RESET_RPS = 2, -- reset the RPS
|
||||
SET_BURN = 3, -- set the burn rate
|
||||
SET_WASTE = 4 -- set the waste processing mode
|
||||
}
|
||||
|
||||
---@alias CAPI_TYPES integer
|
||||
local CAPI_TYPES = {
|
||||
ESTABLISH = 0 -- initial greeting
|
||||
@@ -65,15 +74,12 @@ local CAPI_TYPES = {
|
||||
---@alias RTU_UNIT_TYPES integer
|
||||
local RTU_UNIT_TYPES = {
|
||||
REDSTONE = 0, -- redstone I/O
|
||||
BOILER = 1, -- boiler
|
||||
BOILER_VALVE = 2, -- boiler mekanism 10.1+
|
||||
TURBINE = 3, -- turbine
|
||||
TURBINE_VALVE = 4, -- turbine, mekanism 10.1+
|
||||
EMACHINE = 5, -- energy machine
|
||||
IMATRIX = 6, -- induction matrix
|
||||
SPS = 7, -- SPS
|
||||
SNA = 8, -- SNA
|
||||
ENV_DETECTOR = 9 -- environment detector
|
||||
BOILER_VALVE = 1, -- boiler mekanism 10.1+
|
||||
TURBINE_VALVE = 2, -- turbine, mekanism 10.1+
|
||||
IMATRIX = 3, -- induction matrix
|
||||
SPS = 4, -- SPS
|
||||
SNA = 5, -- SNA
|
||||
ENV_DETECTOR = 6 -- environment detector
|
||||
}
|
||||
|
||||
comms.PROTOCOLS = PROTOCOLS
|
||||
@@ -81,8 +87,13 @@ comms.RPLC_TYPES = RPLC_TYPES
|
||||
comms.RPLC_LINKING = RPLC_LINKING
|
||||
comms.SCADA_MGMT_TYPES = SCADA_MGMT_TYPES
|
||||
comms.SCADA_CRDN_TYPES = SCADA_CRDN_TYPES
|
||||
comms.CRDN_COMMANDS = CRDN_COMMANDS
|
||||
comms.CAPI_TYPES = CAPI_TYPES
|
||||
comms.RTU_UNIT_TYPES = RTU_UNIT_TYPES
|
||||
|
||||
---@alias packet scada_packet|modbus_packet|rplc_packet|mgmt_packet|crdn_packet|capi_packet
|
||||
---@alias frame modbus_frame|rplc_frame|mgmt_frame|crdn_frame|capi_frame
|
||||
|
||||
-- generic SCADA packet object
|
||||
function comms.scada_packet()
|
||||
local self = {
|
||||
@@ -616,16 +627,10 @@ end
|
||||
function comms.rtu_t_to_unit_type(type)
|
||||
if type == rtu_t.redstone then
|
||||
return RTU_UNIT_TYPES.REDSTONE
|
||||
elseif type == rtu_t.boiler then
|
||||
return RTU_UNIT_TYPES.BOILER
|
||||
elseif type == rtu_t.boiler_valve then
|
||||
return RTU_UNIT_TYPES.BOILER_VALVE
|
||||
elseif type == rtu_t.turbine then
|
||||
return RTU_UNIT_TYPES.TURBINE
|
||||
elseif type == rtu_t.turbine_valve then
|
||||
return RTU_UNIT_TYPES.TURBINE_VALVE
|
||||
elseif type == rtu_t.energy_machine then
|
||||
return RTU_UNIT_TYPES.EMACHINE
|
||||
elseif type == rtu_t.induction_matrix then
|
||||
return RTU_UNIT_TYPES.IMATRIX
|
||||
end
|
||||
@@ -639,16 +644,10 @@ end
|
||||
function comms.advert_type_to_rtu_t(utype)
|
||||
if utype == RTU_UNIT_TYPES.REDSTONE then
|
||||
return rtu_t.redstone
|
||||
elseif utype == RTU_UNIT_TYPES.BOILER then
|
||||
return rtu_t.boiler
|
||||
elseif utype == RTU_UNIT_TYPES.BOILER_VALVE then
|
||||
return rtu_t.boiler_valve
|
||||
elseif utype == RTU_UNIT_TYPES.TURBINE then
|
||||
return rtu_t.turbine
|
||||
elseif utype == RTU_UNIT_TYPES.TURBINE_VALVE then
|
||||
return rtu_t.turbine_valve
|
||||
elseif utype == RTU_UNIT_TYPES.EMACHINE then
|
||||
return rtu_t.energy_machine
|
||||
elseif utype == RTU_UNIT_TYPES.IMATRIX then
|
||||
return rtu_t.induction_matrix
|
||||
end
|
||||
|
||||
Reference in New Issue