Merge branch 'pocket-alpha-dev' of https://github.com/MikaylaFischler/cc-mek-scada into pocket-alpha-dev

This commit is contained in:
Mikayla
2024-06-04 00:22:06 +00:00
9 changed files with 288 additions and 58 deletions

View File

@@ -694,24 +694,38 @@ function iocontrol.record_unit_data(data)
local control_status = 1
local reactor_status = 1
local reactor_state = 1
local rps_status = 1
if unit.connected then
-- update RPS status
if unit.reactor_data.rps_tripped then
control_status = 2
rps_status = util.trinary(unit.reactor_data.rps_trip_cause == "manual", 3, 2)
if unit.reactor_data.rps_trip_cause == "manual" then
reactor_state = 4 -- disabled
rps_status = 3
else
reactor_state = 6 -- SCRAM
rps_status = 2
end
else rps_status = 4 end
-- update reactor/control status
if unit.reactor_data.mek_status.status then
reactor_status = 4
reactor_state = 5 -- running
control_status = util.trinary(unit.annunciator.AutoControl, 4, 3)
else
if unit.reactor_data.no_reactor then
reactor_status = 2
elseif not unit.reactor_data.formed or unit.reactor_data.rps_status.force_dis then
reactor_state = 3 -- faulted
elseif not unit.reactor_data.formed then
reactor_status = 3
reactor_state = 2 -- not formed
elseif unit.reactor_data.rps_status.force_dis then
reactor_status = 3
reactor_state = 7 -- force disabled
else
reactor_status = 4
end
@@ -738,6 +752,7 @@ function iocontrol.record_unit_data(data)
unit.unit_ps.publish("U_ControlStatus", control_status)
unit.unit_ps.publish("U_ReactorStatus", reactor_status)
unit.unit_ps.publish("U_ReactorStateStatus", reactor_state)
unit.unit_ps.publish("U_RPS", rps_status)
--#endregion
@@ -751,20 +766,30 @@ function iocontrol.record_unit_data(data)
local ps = unit.boiler_ps_tbl[id] ---@type psil
local boiler_status = 1
local computed_status = 1
if unit.rtu_hw.boilers[id].connected then
if unit.rtu_hw.boilers[id].faulted then
boiler_status = 3
computed_status = 3
elseif boiler.formed then
boiler_status = 4
if boiler.state.boil_rate > 0 then
computed_status = 5
else
computed_status = 4
end
else
boiler_status = 2
computed_status = 2
end
_record_multiblock_status(unit.rtu_hw.boilers[id].faulted, boiler, ps)
end
ps.publish("BoilerStatus", boiler_status)
ps.publish("BoilerStateStatus", computed_status)
end
unit.turbine_data_tbl = data[8]
@@ -774,18 +799,32 @@ function iocontrol.record_unit_data(data)
local ps = unit.turbine_ps_tbl[id] ---@type psil
local turbine_status = 1
local computed_status = 1
if unit.rtu_hw.turbines[id].connected then
if unit.rtu_hw.turbines[id].faulted then
turbine_status = 3
computed_status = 3
elseif turbine.formed then
turbine_status = 4
if turbine.tanks.energy_fill >= 0.99 then
computed_status = 6
elseif turbine.state.flow_rate < 100 then
computed_status = 4
else
computed_status = 5
end
else
turbine_status = 2
computed_status = 2
end
_record_multiblock_status(unit.rtu_hw.turbines[id].faulted, turbine, ps)
end
ps.publish("TurbineStatus", turbine_status)
ps.publish("TurbineStateStatus", computed_status)
end
unit.tank_data_tbl = data[9]