#141 setting unit limits with coordinator
This commit is contained in:
@@ -62,7 +62,6 @@ function iocontrol.init(conf, comms)
|
||||
waste_control = 0,
|
||||
|
||||
a_group = 0, -- auto control group
|
||||
a_limit = 0.0, -- auto control limit
|
||||
|
||||
start = function () process.start(i) end,
|
||||
scram = function () process.scram(i) end,
|
||||
@@ -334,7 +333,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
local unit = io.units[i] ---@type ioctl_entry
|
||||
local status = statuses[i]
|
||||
|
||||
if type(status) ~= "table" or #status ~= 5 then
|
||||
if type(status) ~= "table" or #status ~= 6 then
|
||||
log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)")
|
||||
return false
|
||||
end
|
||||
@@ -343,6 +342,11 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
|
||||
local reactor_status = status[1]
|
||||
|
||||
if type(reactor_status) ~= "table" then
|
||||
reactor_status = {}
|
||||
log.debug(log_header .. "reactor status not a table")
|
||||
end
|
||||
|
||||
if #reactor_status == 0 then
|
||||
unit.reactor_ps.publish("computed_status", 1) -- disconnected
|
||||
elseif #reactor_status == 3 then
|
||||
@@ -512,6 +516,11 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
|
||||
local annunciator = status[3] ---@type annunciator
|
||||
|
||||
if type(annunciator) ~= "table" then
|
||||
annunciator = {}
|
||||
log.debug(log_header .. "annunciator state not a table")
|
||||
end
|
||||
|
||||
for key, val in pairs(annunciator) do
|
||||
if key == "TurbineTrip" then
|
||||
-- split up turbine trip table for all turbines and a general OR combination
|
||||
@@ -580,6 +589,20 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
else
|
||||
log.debug(log_header .. "unit state not a table")
|
||||
end
|
||||
|
||||
-- auto control state fields
|
||||
|
||||
local auto_ctl_state = status[6]
|
||||
|
||||
if type(auto_ctl_state) == "table" then
|
||||
if #auto_ctl_state == 1 then
|
||||
unit.reactor_ps.publish("burn_limit", auto_ctl_state[1])
|
||||
else
|
||||
log.debug(log_header .. "auto control state length mismatch")
|
||||
end
|
||||
else
|
||||
log.debug(log_header .. "auto control state not a table")
|
||||
end
|
||||
end
|
||||
|
||||
-- update alarm sounder
|
||||
|
||||
Reference in New Issue