#229 coordinator changes for UI element register change

This commit is contained in:
Mikayla Fischler
2023-05-14 19:13:12 -04:00
parent e763af9981
commit 466902371a
9 changed files with 178 additions and 181 deletions

View File

@@ -55,9 +55,9 @@ local function new_view(root, x, y)
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=cpair(colors.green,colors.gray)}
local rad_mon = TriIndicatorLight{parent=main,label="Radiation Monitor",c1=colors.gray,c2=colors.yellow,c3=colors.green}
facility.ps.subscribe("all_sys_ok", all_ok.update)
facility.induction_ps_tbl[1].subscribe("computed_status", function (status) ind_mat.update(status > 1) end)
facility.ps.subscribe("rad_computed_status", rad_mon.update)
all_ok.register(facility.ps, "all_sys_ok", all_ok.update)
ind_mat.register(facility.induction_ps_tbl[1], "computed_status", function (status) ind_mat.update(status > 1) end)
rad_mon.register(facility.ps, "rad_computed_status", rad_mon.update)
main.line_break()
@@ -66,10 +66,10 @@ local function new_view(root, x, y)
local auto_ramp = IndicatorLight{parent=main,label="Process Ramping",colors=cpair(colors.white,colors.gray),flash=true,period=period.BLINK_250_MS}
local auto_sat = IndicatorLight{parent=main,label="Min/Max Burn Rate",colors=cpair(colors.yellow,colors.gray)}
facility.ps.subscribe("auto_ready", auto_ready.update)
facility.ps.subscribe("auto_active", auto_act.update)
facility.ps.subscribe("auto_ramping", auto_ramp.update)
facility.ps.subscribe("auto_saturated", auto_sat.update)
auto_ready.register(facility.ps, "auto_ready", auto_ready.update)
auto_act.register(facility.ps, "auto_active", auto_act.update)
auto_ramp.register(facility.ps, "auto_ramping", auto_ramp.update)
auto_sat.register(facility.ps, "auto_saturated", auto_sat.update)
main.line_break()
@@ -80,20 +80,20 @@ local function new_view(root, x, y)
local fac_rad_h = IndicatorLight{parent=main,label="Facility Radiation High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local gen_fault = IndicatorLight{parent=main,label="Gen. Control Fault",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
facility.ps.subscribe("auto_scram", auto_scram.update)
facility.ps.subscribe("as_matrix_dc", matrix_dc.update)
facility.ps.subscribe("as_matrix_fill", matrix_fill.update)
facility.ps.subscribe("as_crit_alarm", unit_crit.update)
facility.ps.subscribe("as_radiation", fac_rad_h.update)
facility.ps.subscribe("as_gen_fault", gen_fault.update)
auto_scram.register(facility.ps, "auto_scram", auto_scram.update)
matrix_dc.register(facility.ps, "as_matrix_dc", matrix_dc.update)
matrix_fill.register(facility.ps, "as_matrix_fill", matrix_fill.update)
unit_crit.register(facility.ps, "as_crit_alarm", unit_crit.update)
fac_rad_h.register(facility.ps, "as_radiation", fac_rad_h.update)
gen_fault.register(facility.ps, "as_gen_fault", gen_fault.update)
TextBox{parent=main,y=23,text="Radiation",height=1,width=13,fg_bg=style.label}
local radiation = RadIndicator{parent=main,label="",format="%9.3f",lu_colors=lu_cpair,width=13,fg_bg=bw_fg_bg}
facility.ps.subscribe("radiation", radiation.update)
radiation.register(facility.ps, "radiation", radiation.update)
TextBox{parent=main,x=15,y=23,text="Linked RTUs",height=1,width=11,fg_bg=style.label}
local rtu_count = DataIndicator{parent=main,x=15,y=24,label="",format="%11d",value=0,lu_colors=lu_cpair,width=11,fg_bg=bw_fg_bg}
facility.ps.subscribe("rtu_count", rtu_count.update)
rtu_count.register(facility.ps, "rtu_count", rtu_count.update)
---------------------
-- process control --
@@ -115,8 +115,8 @@ local function new_view(root, x, y)
TextBox{parent=burn_target,x=18,y=2,text="mB/t"}
local burn_sum = DataIndicator{parent=targets,x=9,y=4,label="",format="%18.1f",value=0,unit="mB/t",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_burn_target", b_target.set_value)
facility.ps.subscribe("burn_sum", burn_sum.update)
b_target.register(facility.ps, "process_burn_target", b_target.set_value)
burn_sum.register(facility.ps, "burn_sum", burn_sum.update)
local chg_tag = Div{parent=targets,x=1,y=6,width=8,height=4,fg_bg=cpair(colors.black,colors.purple)}
TextBox{parent=chg_tag,x=2,y=2,text="Charge Target",width=7,height=2}
@@ -126,8 +126,8 @@ local function new_view(root, x, y)
TextBox{parent=chg_target,x=18,y=2,text="MFE"}
local cur_charge = DataIndicator{parent=targets,x=9,y=9,label="",format="%19d",value=0,unit="MFE",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_charge_target", c_target.set_value)
facility.induction_ps_tbl[1].subscribe("energy", function (j) cur_charge.update(util.joules_to_fe(j) / 1000000) end)
c_target.register(facility.ps, "process_charge_target", c_target.set_value)
cur_charge.register(facility.induction_ps_tbl[1], "energy", function (j) cur_charge.update(util.joules_to_fe(j) / 1000000) end)
local gen_tag = Div{parent=targets,x=1,y=11,width=8,height=4,fg_bg=cpair(colors.black,colors.purple)}
TextBox{parent=gen_tag,x=2,y=2,text="Gen. Target",width=7,height=2}
@@ -137,8 +137,8 @@ local function new_view(root, x, y)
TextBox{parent=gen_target,x=18,y=2,text="kFE/t"}
local cur_gen = DataIndicator{parent=targets,x=9,y=14,label="",format="%17d",value=0,unit="kFE/t",commas=true,lu_colors=cpair(colors.black,colors.black),width=23,fg_bg=cpair(colors.black,colors.brown)}
facility.ps.subscribe("process_gen_target", g_target.set_value)
facility.induction_ps_tbl[1].subscribe("last_input", function (j) cur_gen.update(util.round(util.joules_to_fe(j) / 1000)) end)
g_target.register(facility.ps, "process_gen_target", g_target.set_value)
cur_gen.register(facility.induction_ps_tbl[1], "last_input", function (j) cur_gen.update(util.round(util.joules_to_fe(j) / 1000)) end)
-----------------
-- unit limits --
@@ -160,12 +160,12 @@ local function new_view(root, x, y)
rate_limits[i] = SpinboxNumeric{parent=lim_ctl,x=2,y=1,whole_num_precision=4,fractional_precision=1,min=0.1,arrow_fg_bg=cpair(colors.gray,colors.white),fg_bg=bw_fg_bg}
TextBox{parent=lim_ctl,x=9,y=2,text="mB/t",width=4,height=1}
unit.unit_ps.subscribe("max_burn", rate_limits[i].set_max)
unit.unit_ps.subscribe("burn_limit", rate_limits[i].set_value)
rate_limits[i].register(unit.unit_ps, "max_burn", rate_limits[i].set_max)
rate_limits[i].register(unit.unit_ps, "burn_limit", rate_limits[i].set_value)
local cur_burn = DataIndicator{parent=limit_div,x=9,y=_y+3,label="",format="%7.1f",value=0,unit="mB/t",commas=false,lu_colors=cpair(colors.black,colors.black),width=14,fg_bg=cpair(colors.black,colors.brown)}
unit.unit_ps.subscribe("act_burn_rate", cur_burn.update)
cur_burn.register(unit.unit_ps, "act_burn_rate", cur_burn.update)
end
-------------------
@@ -186,8 +186,8 @@ local function new_view(root, x, y)
local ready = IndicatorLight{parent=lights,x=2,y=2,label="Ready",colors=cpair(colors.green,colors.gray)}
local degraded = IndicatorLight{parent=lights,x=2,y=3,label="Degraded",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
unit.unit_ps.subscribe("U_AutoReady", ready.update)
unit.unit_ps.subscribe("U_AutoDegraded", degraded.update)
ready.register(unit.unit_ps, "U_AutoReady", ready.update)
degraded.register(unit.unit_ps, "U_AutoDegraded", degraded.update)
end
-------------------------
@@ -197,14 +197,14 @@ local function new_view(root, x, y)
local ctl_opts = { "Monitored Max Burn", "Combined Burn Rate", "Charge Level", "Generation Rate" }
local mode = RadioButton{parent=proc,x=34,y=1,options=ctl_opts,callback=function()end,radio_colors=cpair(colors.purple,colors.black),radio_bg=colors.gray}
facility.ps.subscribe("process_mode", mode.set_value)
mode.register(facility.ps, "process_mode", mode.set_value)
local u_stat = Rectangle{parent=proc,border=border(1,colors.gray,true),thin=true,width=31,height=4,x=1,y=16,fg_bg=bw_fg_bg}
local stat_line_1 = TextBox{parent=u_stat,x=1,y=1,text="UNKNOWN",width=31,height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=bw_fg_bg}
local stat_line_2 = TextBox{parent=u_stat,x=1,y=2,text="awaiting data...",width=31,height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=cpair(colors.gray, colors.white)}
facility.ps.subscribe("status_line_1", stat_line_1.set_value)
facility.ps.subscribe("status_line_2", stat_line_2.set_value)
stat_line_1.register(facility.ps, "status_line_1", stat_line_1.set_value)
stat_line_2.register(facility.ps, "status_line_2", stat_line_2.set_value)
local auto_controls = Div{parent=proc,x=1,y=20,width=31,height=5,fg_bg=cpair(colors.gray,colors.white)}
@@ -233,11 +233,14 @@ local function new_view(root, x, y)
tcd.dispatch(0.2, function () save.on_response(ack) end)
end
facility.ps.subscribe("auto_ready", function (ready)
start.register(facility.ps, "auto_ready", function (ready)
if ready and (not facility.auto_active) then start.enable() else start.disable() end
end)
facility.ps.subscribe("auto_active", function (active)
-- REGISTER_NOTE: for optimization/brevity, due to not deleting anything but the whole element tree when it comes
-- to the process control display and coordinator GUI as a whole, child elements will not directly be registered here
-- (preventing garbage collection until the parent 'proc' is deleted)
proc.register(facility.ps, "auto_active", function (active)
if active then
b_target.disable()
c_target.disable()
@@ -246,9 +249,7 @@ local function new_view(root, x, y)
mode.disable()
start.disable()
for i = 1, #rate_limits do
rate_limits[i].disable()
end
for i = 1, #rate_limits do rate_limits[i].disable() end
else
b_target.enable()
c_target.enable()
@@ -257,9 +258,7 @@ local function new_view(root, x, y)
mode.enable()
if facility.auto_ready then start.enable() end
for i = 1, #rate_limits do
rate_limits[i].enable()
end
for i = 1, #rate_limits do rate_limits[i].enable() end
end
end)
end