#157 fixed bug with RTU remount messages
This commit is contained in:
@@ -157,16 +157,20 @@ function threads.thread__main(smem)
|
||||
|
||||
if unit.type == rtu_t.boiler_valve then
|
||||
unit.rtu = boilerv_rtu.new(device)
|
||||
unit.formed = true
|
||||
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
|
||||
unit.formed = util.trinary(device.__p_is_faulted(), false, nil)
|
||||
elseif unit.type == rtu_t.turbine_valve then
|
||||
unit.rtu = turbinev_rtu.new(device)
|
||||
unit.formed = true
|
||||
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
|
||||
unit.formed = util.trinary(device.__p_is_faulted(), false, nil)
|
||||
elseif unit.type == rtu_t.induction_matrix then
|
||||
unit.rtu = imatrix_rtu.new(device)
|
||||
unit.formed = true
|
||||
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
|
||||
unit.formed = util.trinary(device.__p_is_faulted(), false, nil)
|
||||
elseif unit.type == rtu_t.sps then
|
||||
unit.rtu = sps_rtu.new(device)
|
||||
unit.formed = true
|
||||
-- if not formed, indexing the multiblock functions would have resulted in a PPM fault
|
||||
unit.formed = util.trinary(device.__p_is_faulted(), false, nil)
|
||||
elseif unit.type == rtu_t.sna then
|
||||
unit.rtu = sna_rtu.new(device)
|
||||
elseif unit.type == rtu_t.env_detector then
|
||||
@@ -175,6 +179,10 @@ function threads.thread__main(smem)
|
||||
log.error(util.c("failed to identify reconnected RTU unit type (", unit.name, ")"), true)
|
||||
end
|
||||
|
||||
if unit.is_multiblock and (unit.formed == false) then
|
||||
log.info(util.c("assuming ", unit.name, " is not formed due to PPM faults while initializing"))
|
||||
end
|
||||
|
||||
unit.modbus_io = modbus.new(unit.rtu, true)
|
||||
|
||||
println_ts("reconnected the " .. unit.type .. " on interface " .. unit.name)
|
||||
@@ -183,7 +191,7 @@ function threads.thread__main(smem)
|
||||
if resend_advert then
|
||||
rtu_comms.send_advertisement(units)
|
||||
else
|
||||
rtu_comms.send_remounted(unit.index)
|
||||
rtu_comms.send_remounted(unit.uid)
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -342,9 +350,13 @@ function threads.thread__unit_comms(smem, unit)
|
||||
end
|
||||
|
||||
-- check if multiblock is still formed if this is a multiblock
|
||||
if (type(unit.formed) == "boolean") and (util.time() - last_f_check > 1000) then
|
||||
if unit.is_multiblock and (util.time_ms() - last_f_check > 250) then
|
||||
local is_formed = unit.device.isFormed()
|
||||
|
||||
last_f_check = util.time_ms()
|
||||
|
||||
if unit.formed == nil then unit.formed = is_formed end
|
||||
|
||||
if (not unit.formed) and is_formed then
|
||||
-- newly re-formed
|
||||
local iface = ppm.get_iface(unit.device)
|
||||
@@ -384,13 +396,13 @@ function threads.thread__unit_comms(smem, unit)
|
||||
log.error("illegal remount of non-multiblock RTU attempted for " .. short_name, true)
|
||||
end
|
||||
|
||||
rtu_comms.send_remounted(unit.index)
|
||||
rtu_comms.send_remounted(unit.uid)
|
||||
else
|
||||
-- fully lost the peripheral now :(
|
||||
log.error(util.c(unit.name, " lost (failed reconnect)"))
|
||||
end
|
||||
|
||||
log.info("reconnected the " .. unit.type .. " on interface " .. unit.name)
|
||||
log.info(util.c("reconnected the ", unit.type, " on interface ", unit.name))
|
||||
else
|
||||
log.error("failed to get interface of previously connected RTU unit " .. detail_name, true)
|
||||
end
|
||||
|
||||