#64 rtu code cleanup and device bugfixes
This commit is contained in:
@@ -4,55 +4,52 @@ local boilerv_rtu = {}
|
||||
|
||||
-- create new boiler (mek 10.1+) device
|
||||
---@param boiler table
|
||||
boilerv_rtu.new = function (boiler)
|
||||
local self = {
|
||||
rtu = rtu.init_unit(),
|
||||
boiler = boiler
|
||||
}
|
||||
function boilerv_rtu.new(boiler)
|
||||
local unit = rtu.init_unit()
|
||||
|
||||
-- discrete inputs --
|
||||
self.rtu.connect_di(self.boiler.isFormed)
|
||||
unit.connect_di(boiler.isFormed)
|
||||
|
||||
-- coils --
|
||||
-- none
|
||||
|
||||
-- input registers --
|
||||
-- multiblock properties
|
||||
self.rtu.connect_input_reg(self.boiler.getLength)
|
||||
self.rtu.connect_input_reg(self.boiler.getWidth)
|
||||
self.rtu.connect_input_reg(self.boiler.getHeight)
|
||||
self.rtu.connect_input_reg(self.boiler.getMinPos)
|
||||
self.rtu.connect_input_reg(self.boiler.getMaxPos)
|
||||
unit.connect_input_reg(boiler.getLength)
|
||||
unit.connect_input_reg(boiler.getWidth)
|
||||
unit.connect_input_reg(boiler.getHeight)
|
||||
unit.connect_input_reg(boiler.getMinPos)
|
||||
unit.connect_input_reg(boiler.getMaxPos)
|
||||
-- build properties
|
||||
self.rtu.connect_input_reg(self.boiler.getBoilCapacity)
|
||||
self.rtu.connect_input_reg(self.boiler.getSteamCapacity)
|
||||
self.rtu.connect_input_reg(self.boiler.getWaterCapacity)
|
||||
self.rtu.connect_input_reg(self.boiler.getHeatedCoolantCapacity)
|
||||
self.rtu.connect_input_reg(self.boiler.getCooledCoolantCapacity)
|
||||
self.rtu.connect_input_reg(self.boiler.getSuperheaters)
|
||||
self.rtu.connect_input_reg(self.boiler.getMaxBoilRate)
|
||||
self.rtu.connect_input_reg(self.boiler.getEnvironmentalLoss)
|
||||
unit.connect_input_reg(boiler.getBoilCapacity)
|
||||
unit.connect_input_reg(boiler.getSteamCapacity)
|
||||
unit.connect_input_reg(boiler.getWaterCapacity)
|
||||
unit.connect_input_reg(boiler.getHeatedCoolantCapacity)
|
||||
unit.connect_input_reg(boiler.getCooledCoolantCapacity)
|
||||
unit.connect_input_reg(boiler.getSuperheaters)
|
||||
unit.connect_input_reg(boiler.getMaxBoilRate)
|
||||
unit.connect_input_reg(boiler.getEnvironmentalLoss)
|
||||
-- current state
|
||||
self.rtu.connect_input_reg(self.boiler.getTemperature)
|
||||
self.rtu.connect_input_reg(self.boiler.getBoilRate)
|
||||
unit.connect_input_reg(boiler.getTemperature)
|
||||
unit.connect_input_reg(boiler.getBoilRate)
|
||||
-- tanks
|
||||
self.rtu.connect_input_reg(self.boiler.getSteam)
|
||||
self.rtu.connect_input_reg(self.boiler.getSteamNeeded)
|
||||
self.rtu.connect_input_reg(self.boiler.getSteamFilledPercentage)
|
||||
self.rtu.connect_input_reg(self.boiler.getWater)
|
||||
self.rtu.connect_input_reg(self.boiler.getWaterNeeded)
|
||||
self.rtu.connect_input_reg(self.boiler.getWaterFilledPercentage)
|
||||
self.rtu.connect_input_reg(self.boiler.getHeatedCoolant)
|
||||
self.rtu.connect_input_reg(self.boiler.getHeatedCoolantNeeded)
|
||||
self.rtu.connect_input_reg(self.boiler.getHeatedCoolantFilledPercentage)
|
||||
self.rtu.connect_input_reg(self.boiler.getCooledCoolant)
|
||||
self.rtu.connect_input_reg(self.boiler.getCooledCoolantNeeded)
|
||||
self.rtu.connect_input_reg(self.boiler.getCooledCoolantFilledPercentage)
|
||||
unit.connect_input_reg(boiler.getSteam)
|
||||
unit.connect_input_reg(boiler.getSteamNeeded)
|
||||
unit.connect_input_reg(boiler.getSteamFilledPercentage)
|
||||
unit.connect_input_reg(boiler.getWater)
|
||||
unit.connect_input_reg(boiler.getWaterNeeded)
|
||||
unit.connect_input_reg(boiler.getWaterFilledPercentage)
|
||||
unit.connect_input_reg(boiler.getHeatedCoolant)
|
||||
unit.connect_input_reg(boiler.getHeatedCoolantNeeded)
|
||||
unit.connect_input_reg(boiler.getHeatedCoolantFilledPercentage)
|
||||
unit.connect_input_reg(boiler.getCooledCoolant)
|
||||
unit.connect_input_reg(boiler.getCooledCoolantNeeded)
|
||||
unit.connect_input_reg(boiler.getCooledCoolantFilledPercentage)
|
||||
|
||||
-- holding registers --
|
||||
-- none
|
||||
|
||||
return self.rtu.interface()
|
||||
return unit.interface()
|
||||
end
|
||||
|
||||
return boilerv_rtu
|
||||
|
||||
Reference in New Issue