#545 pocket type annotation updates
This commit is contained in:
@@ -39,15 +39,6 @@ local io = {
|
||||
ps = psil.create()
|
||||
}
|
||||
|
||||
-- luacheck: no unused args
|
||||
|
||||
-- placeholder acknowledge function for type hinting
|
||||
---@param success boolean
|
||||
---@diagnostic disable-next-line: unused-local
|
||||
local function __generic_ack(success) end
|
||||
|
||||
-- luacheck: unused args
|
||||
|
||||
local config = nil ---@type pkt_config
|
||||
local comms = nil ---@type pocket_comms
|
||||
|
||||
@@ -93,9 +84,9 @@ function iocontrol.init_core(pkt_comms, nav, cfg)
|
||||
get_tone_states = function () comms.diag__get_alarm_tones() end,
|
||||
|
||||
ready_warn = nil, ---@type graphics_element
|
||||
tone_buttons = {},
|
||||
alarm_buttons = {},
|
||||
tone_indicators = {} -- indicators to update from supervisor tone states
|
||||
tone_buttons = {}, ---@type graphics_element[]
|
||||
alarm_buttons = {}, ---@type graphics_element[]
|
||||
tone_indicators = {} ---@type graphics_element[] indicators to update from supervisor tone states
|
||||
}
|
||||
|
||||
-- API access
|
||||
@@ -166,24 +157,21 @@ function iocontrol.init_fac(conf)
|
||||
|
||||
radiation = types.new_zero_radiation_reading(),
|
||||
|
||||
start_ack = __generic_ack,
|
||||
stop_ack = __generic_ack,
|
||||
scram_ack = __generic_ack,
|
||||
ack_alarms_ack = __generic_ack,
|
||||
start_ack = nil, ---@type fun(success: boolean)
|
||||
stop_ack = nil, ---@type fun(success: boolean)
|
||||
scram_ack = nil, ---@type fun(success: boolean)
|
||||
ack_alarms_ack = nil, ---@type fun(success: boolean)
|
||||
|
||||
ps = psil.create(),
|
||||
|
||||
induction_ps_tbl = {},
|
||||
induction_data_tbl = {},
|
||||
induction_ps_tbl = {}, ---@type psil[]
|
||||
induction_data_tbl = {}, ---@type imatrix_session_db[]
|
||||
|
||||
sps_ps_tbl = {},
|
||||
sps_data_tbl = {},
|
||||
sps_ps_tbl = {}, ---@type psil[]
|
||||
sps_data_tbl = {}, ---@type sps_session_db[]
|
||||
|
||||
tank_ps_tbl = {},
|
||||
tank_data_tbl = {},
|
||||
|
||||
env_d_ps = psil.create(),
|
||||
env_d_data = {}
|
||||
tank_ps_tbl = {}, ---@type psil[]
|
||||
tank_data_tbl = {} ---@type dynamicv_session_db[]
|
||||
}
|
||||
|
||||
-- create induction and SPS tables (currently only 1 of each is supported)
|
||||
@@ -192,107 +180,14 @@ function iocontrol.init_fac(conf)
|
||||
table.insert(io.facility.sps_ps_tbl, psil.create())
|
||||
table.insert(io.facility.sps_data_tbl, {})
|
||||
|
||||
-- determine tank information
|
||||
if io.facility.tank_mode == 0 then
|
||||
io.facility.tank_defs = {}
|
||||
-- on facility tank mode 0, setup tank defs to match unit tank option
|
||||
for i = 1, conf.num_units do
|
||||
io.facility.tank_defs[i] = util.trinary(conf.cooling.r_cool[i].TankConnection, 1, 0)
|
||||
end
|
||||
|
||||
io.facility.tank_list = { table.unpack(io.facility.tank_defs) }
|
||||
else
|
||||
-- decode the layout of tanks from the connections definitions
|
||||
local tank_mode = io.facility.tank_mode
|
||||
local tank_defs = io.facility.tank_defs
|
||||
local tank_list = { table.unpack(tank_defs) }
|
||||
|
||||
local function calc_fdef(start_idx, end_idx)
|
||||
local first = 4
|
||||
for i = start_idx, end_idx do
|
||||
if io.facility.tank_defs[i] == 2 then
|
||||
if i < first then first = i end
|
||||
end
|
||||
end
|
||||
return first
|
||||
end
|
||||
|
||||
if tank_mode == 1 then
|
||||
-- (1) 1 total facility tank (A A A A)
|
||||
local first_fdef = calc_fdef(1, #tank_defs)
|
||||
for i = 1, #tank_defs do
|
||||
if i > first_fdef and tank_defs[i] == 2 then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 2 then
|
||||
-- (2) 2 total facility tanks (A A A B)
|
||||
local first_fdef = calc_fdef(1, math.min(3, #tank_defs))
|
||||
for i = 1, #tank_defs do
|
||||
if (i ~= 4) and (i > first_fdef) and (tank_defs[i] == 2) then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 3 then
|
||||
-- (3) 2 total facility tanks (A A B B)
|
||||
for _, a in pairs({ 1, 3 }) do
|
||||
local b = a + 1
|
||||
if (tank_defs[a] == 2) and (tank_defs[b] == 2) then
|
||||
tank_list[b] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 4 then
|
||||
-- (4) 2 total facility tanks (A B B B)
|
||||
local first_fdef = calc_fdef(2, #tank_defs)
|
||||
for i = 1, #tank_defs do
|
||||
if (i ~= 1) and (i > first_fdef) and (tank_defs[i] == 2) then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 5 then
|
||||
-- (5) 3 total facility tanks (A A B C)
|
||||
local first_fdef = calc_fdef(1, math.min(2, #tank_defs))
|
||||
for i = 1, #tank_defs do
|
||||
if (not (i == 3 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 6 then
|
||||
-- (6) 3 total facility tanks (A B B C)
|
||||
local first_fdef = calc_fdef(2, math.min(3, #tank_defs))
|
||||
for i = 1, #tank_defs do
|
||||
if (not (i == 1 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
elseif tank_mode == 7 then
|
||||
-- (7) 3 total facility tanks (A B C C)
|
||||
local first_fdef = calc_fdef(3, #tank_defs)
|
||||
for i = 1, #tank_defs do
|
||||
if (not (i == 1 or i == 2)) and (i > first_fdef) and (tank_defs[i] == 2) then
|
||||
tank_list[i] = 0
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
io.facility.tank_list = tank_list
|
||||
end
|
||||
|
||||
-- create facility tank tables
|
||||
for i = 1, #io.facility.tank_list do
|
||||
if io.facility.tank_list[i] == 2 then
|
||||
table.insert(io.facility.tank_ps_tbl, psil.create())
|
||||
table.insert(io.facility.tank_data_tbl, {})
|
||||
end
|
||||
end
|
||||
|
||||
-- create unit data structures
|
||||
io.units = {}
|
||||
io.units = {} ---@type pioctl_unit[]
|
||||
for i = 1, conf.num_units do
|
||||
---@class pioctl_unit
|
||||
local entry = {
|
||||
unit_id = i,
|
||||
connected = false,
|
||||
---@type { boilers: { connected: boolean, faulted: boolean }[], turbines: { connected: boolean, faulted: boolean }[] }
|
||||
rtu_hw = {},
|
||||
|
||||
num_boilers = 0,
|
||||
@@ -323,27 +218,27 @@ function iocontrol.init_fac(conf)
|
||||
ack_alarms = function () process.ack_all_alarms(i) end,
|
||||
set_burn = function (rate) process.set_rate(i, rate) end, ---@param rate number burn rate
|
||||
|
||||
start_ack = __generic_ack,
|
||||
scram_ack = __generic_ack,
|
||||
reset_rps_ack = __generic_ack,
|
||||
ack_alarms_ack = __generic_ack,
|
||||
start_ack = nil, ---@type fun(success: boolean)
|
||||
scram_ack = nil, ---@type fun(success: boolean)
|
||||
reset_rps_ack = nil, ---@type fun(success: boolean)
|
||||
ack_alarms_ack = nil, ---@type fun(success: boolean)
|
||||
|
||||
---@type alarms
|
||||
alarms = { ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE, ALARM_STATE.INACTIVE },
|
||||
|
||||
annunciator = {}, ---@type annunciator
|
||||
annunciator = {}, ---@type annunciator
|
||||
|
||||
unit_ps = psil.create(),
|
||||
reactor_data = {}, ---@type reactor_db
|
||||
reactor_data = {}, ---@type reactor_db
|
||||
|
||||
boiler_ps_tbl = {},
|
||||
boiler_data_tbl = {},
|
||||
boiler_ps_tbl = {}, ---@type psil[]
|
||||
boiler_data_tbl = {}, ---@type boilerv_session_db[]
|
||||
|
||||
turbine_ps_tbl = {},
|
||||
turbine_data_tbl = {},
|
||||
turbine_ps_tbl = {}, ---@type psil[]
|
||||
turbine_data_tbl = {}, ---@type turbinev_session_db[]
|
||||
|
||||
tank_ps_tbl = {},
|
||||
tank_data_tbl = {}
|
||||
tank_ps_tbl = {}, ---@type psil[]
|
||||
tank_data_tbl = {} ---@type dynamicv_session_db[]
|
||||
}
|
||||
|
||||
-- on other facility modes, overwrite unit TANK option with facility tank defs
|
||||
@@ -485,7 +380,7 @@ end
|
||||
-- update unit status data from API_GET_UNIT
|
||||
---@param data table
|
||||
function iocontrol.record_unit_data(data)
|
||||
local unit = io.units[data[1]] ---@type pioctl_unit
|
||||
local unit = io.units[data[1]]
|
||||
|
||||
unit.connected = data[2]
|
||||
unit.rtu_hw = data[3]
|
||||
@@ -650,8 +545,8 @@ function iocontrol.record_unit_data(data)
|
||||
unit.boiler_data_tbl = data[8]
|
||||
|
||||
for id = 1, #unit.boiler_data_tbl do
|
||||
local boiler = unit.boiler_data_tbl[id] ---@type boilerv_session_db
|
||||
local ps = unit.boiler_ps_tbl[id] ---@type psil
|
||||
local boiler = unit.boiler_data_tbl[id]
|
||||
local ps = unit.boiler_ps_tbl[id]
|
||||
|
||||
local boiler_status = 1
|
||||
local computed_status = 1
|
||||
@@ -683,8 +578,8 @@ function iocontrol.record_unit_data(data)
|
||||
unit.turbine_data_tbl = data[9]
|
||||
|
||||
for id = 1, #unit.turbine_data_tbl do
|
||||
local turbine = unit.turbine_data_tbl[id] ---@type turbinev_session_db
|
||||
local ps = unit.turbine_ps_tbl[id] ---@type psil
|
||||
local turbine = unit.turbine_data_tbl[id]
|
||||
local ps = unit.turbine_ps_tbl[id]
|
||||
|
||||
local turbine_status = 1
|
||||
local computed_status = 1
|
||||
|
||||
Reference in New Issue