#76 added trusted connection ranges for modem messages

This commit is contained in:
Mikayla Fischler
2023-02-07 17:31:22 -05:00
parent 1d3a1672c8
commit 6c09772a74
13 changed files with 109 additions and 62 deletions

View File

@@ -8,6 +8,8 @@ config.REACTOR_ID = 1
config.SERVER_PORT = 16000
-- port to listen to incoming packets FROM server
config.LISTEN_PORT = 14001
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- log path
config.LOG_PATH = "/log.txt"
-- log mode

View File

@@ -404,15 +404,16 @@ function plc.rps_init(reactor, is_formed)
end
-- Reactor PLC Communications
---@param id integer
---@param version string
---@param modem table
---@param local_port integer
---@param server_port integer
---@param reactor table
---@param rps rps
---@param conn_watchdog watchdog
function plc.comms(id, version, modem, local_port, server_port, reactor, rps, conn_watchdog)
---@param id integer reactor ID
---@param version string PLC version
---@param modem table modem device
---@param local_port integer local listening port
---@param server_port integer remote server port
---@param range integer trusted device connection range
---@param reactor table reactor device
---@param rps rps RPS reference
---@param conn_watchdog watchdog watchdog reference
function plc.comms(id, version, modem, local_port, server_port, range, reactor, rps, conn_watchdog)
local self = {
seq_num = 0,
r_seq_num = nil,
@@ -428,6 +429,13 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
max_burn_rate = nil
}
---@class plc_comms
local public = {}
comms.set_trusted_range(range)
-- PRIVATE FUNCTIONS --
-- configure modem channels
local function _conf_channels()
self.modem.closeAll()
@@ -436,11 +444,6 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
_conf_channels()
---@class plc_comms
local public = {}
-- PRIVATE FUNCTIONS --
-- send an RPLC packet
---@param msg_type RPLC_TYPES
---@param msg table

View File

@@ -14,7 +14,7 @@ local config = require("reactor-plc.config")
local plc = require("reactor-plc.plc")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "beta-v0.10.5"
local R_PLC_VERSION = "beta-v0.10.6"
local print = util.print
local println = util.println
@@ -31,6 +31,7 @@ cfv.assert_type_bool(config.NETWORKED)
cfv.assert_type_int(config.REACTOR_ID)
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
assert(cfv.valid(), "bad config file: missing/invalid fields")
@@ -162,7 +163,7 @@ local function main()
-- start comms
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
config.TRUSTED_RANGE, smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
log.debug("init> comms init")
else