#118 refactoring of comms types
This commit is contained in:
@@ -8,11 +8,11 @@ local plc = {}
|
||||
|
||||
local rps_status_t = types.rps_status_t
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local DEVICE_TYPES = comms.DEVICE_TYPES
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local DEVICE_TYPE = comms.DEVICE_TYPE
|
||||
local ESTABLISH_ACK = comms.ESTABLISH_ACK
|
||||
local RPLC_TYPES = comms.RPLC_TYPES
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local RPLC_TYPE = comms.RPLC_TYPE
|
||||
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
||||
local AUTO_ACK = comms.PLC_AUTO_ACK
|
||||
|
||||
local print = util.print
|
||||
@@ -444,28 +444,28 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
_conf_channels()
|
||||
|
||||
-- send an RPLC packet
|
||||
---@param msg_type RPLC_TYPES
|
||||
---@param msg_type RPLC_TYPE
|
||||
---@param msg table
|
||||
local function _send(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local r_pkt = comms.rplc_packet()
|
||||
|
||||
r_pkt.make(id, msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.RPLC, r_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send a SCADA management packet
|
||||
---@param msg_type SCADA_MGMT_TYPES
|
||||
---@param msg_type SCADA_MGMT_TYPE
|
||||
---@param msg table
|
||||
local function _send_mgmt(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
|
||||
self.seq_num = self.seq_num + 1
|
||||
@@ -569,11 +569,11 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
-- keep alive ack
|
||||
---@param srv_time integer
|
||||
local function _send_keep_alive_ack(srv_time)
|
||||
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { srv_time, util.time() })
|
||||
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { srv_time, util.time() })
|
||||
end
|
||||
|
||||
-- general ack
|
||||
---@param msg_type RPLC_TYPES
|
||||
---@param msg_type RPLC_TYPE
|
||||
---@param status boolean|integer
|
||||
local function _send_ack(msg_type, status)
|
||||
_send(msg_type, { status })
|
||||
@@ -605,7 +605,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
parallel.waitForAll(table.unpack(tasks))
|
||||
|
||||
if not self.reactor.__p_is_faulted() then
|
||||
_send(RPLC_TYPES.MEK_STRUCT, mek_data)
|
||||
_send(RPLC_TYPE.MEK_STRUCT, mek_data)
|
||||
self.resend_build = false
|
||||
else
|
||||
log.error("failed to send structure: PPM fault")
|
||||
@@ -643,12 +643,12 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
function public.close()
|
||||
conn_watchdog.cancel()
|
||||
public.unlink()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
|
||||
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
|
||||
end
|
||||
|
||||
-- attempt to establish link with supervisor
|
||||
function public.send_link_req()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.ESTABLISH, { comms.version, version, DEVICE_TYPES.PLC, id })
|
||||
_send_mgmt(SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.PLC, id })
|
||||
end
|
||||
|
||||
-- send live status information
|
||||
@@ -677,7 +677,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
mek_data -- mekanism status data
|
||||
}
|
||||
|
||||
_send(RPLC_TYPES.STATUS, sys_status)
|
||||
_send(RPLC_TYPE.STATUS, sys_status)
|
||||
|
||||
if self.resend_build then
|
||||
_send_struct()
|
||||
@@ -688,7 +688,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
-- send reactor protection system status
|
||||
function public.send_rps_status()
|
||||
if self.linked then
|
||||
_send(RPLC_TYPES.RPS_STATUS, { rps.is_tripped(), rps.get_trip_cause(), table.unpack(rps.status()) })
|
||||
_send(RPLC_TYPE.RPS_STATUS, { rps.is_tripped(), rps.get_trip_cause(), table.unpack(rps.status()) })
|
||||
end
|
||||
end
|
||||
|
||||
@@ -701,7 +701,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
table.unpack(rps.status())
|
||||
}
|
||||
|
||||
_send(RPLC_TYPES.RPS_ALARM, rps_alarm)
|
||||
_send(RPLC_TYPE.RPS_ALARM, rps_alarm)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -721,13 +721,13 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
|
||||
if s_pkt.is_valid() then
|
||||
-- get as RPLC packet
|
||||
if s_pkt.protocol() == PROTOCOLS.RPLC then
|
||||
if s_pkt.protocol() == PROTOCOL.RPLC then
|
||||
local rplc_pkt = comms.rplc_packet()
|
||||
if rplc_pkt.decode(s_pkt) then
|
||||
pkt = rplc_pkt.get()
|
||||
end
|
||||
-- get as SCADA management packet
|
||||
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
local mgmt_pkt = comms.mgmt_packet()
|
||||
if mgmt_pkt.decode(s_pkt) then
|
||||
pkt = mgmt_pkt.get()
|
||||
@@ -762,18 +762,18 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
-- handle packet
|
||||
if protocol == PROTOCOLS.RPLC then
|
||||
if protocol == PROTOCOL.RPLC then
|
||||
if self.linked then
|
||||
if packet.type == RPLC_TYPES.STATUS then
|
||||
if packet.type == RPLC_TYPE.STATUS then
|
||||
-- request of full status, clear cache first
|
||||
self.status_cache = nil
|
||||
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
|
||||
log.debug("sent out status cache again, did supervisor miss it?")
|
||||
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
|
||||
elseif packet.type == RPLC_TYPE.MEK_STRUCT then
|
||||
-- request for physical structure
|
||||
_send_struct()
|
||||
log.debug("sent out structure again, did supervisor miss it?")
|
||||
elseif packet.type == RPLC_TYPES.MEK_BURN_RATE then
|
||||
elseif packet.type == RPLC_TYPE.MEK_BURN_RATE then
|
||||
-- set the burn rate
|
||||
if (packet.length == 2) and (type(packet.data[1]) == "number") then
|
||||
local success = false
|
||||
@@ -805,29 +805,29 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
else
|
||||
log.debug("RPLC set burn rate packet length mismatch or non-numeric burn rate")
|
||||
end
|
||||
elseif packet.type == RPLC_TYPES.RPS_ENABLE then
|
||||
elseif packet.type == RPLC_TYPE.RPS_ENABLE then
|
||||
-- enable the reactor
|
||||
self.scrammed = false
|
||||
_send_ack(packet.type, rps.activate())
|
||||
elseif packet.type == RPLC_TYPES.RPS_SCRAM then
|
||||
elseif packet.type == RPLC_TYPE.RPS_SCRAM then
|
||||
-- disable the reactor per manual request
|
||||
self.scrammed = true
|
||||
rps.trip_manual()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.RPS_ASCRAM then
|
||||
elseif packet.type == RPLC_TYPE.RPS_ASCRAM then
|
||||
-- disable the reactor per automatic request
|
||||
self.scrammed = true
|
||||
rps.trip_auto()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.RPS_RESET then
|
||||
elseif packet.type == RPLC_TYPE.RPS_RESET then
|
||||
-- reset the RPS status
|
||||
rps.reset()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.RPS_AUTO_RESET then
|
||||
elseif packet.type == RPLC_TYPE.RPS_AUTO_RESET then
|
||||
-- reset automatic SCRAM and timeout trips
|
||||
rps.auto_reset()
|
||||
_send_ack(packet.type, true)
|
||||
elseif packet.type == RPLC_TYPES.AUTO_BURN_RATE then
|
||||
elseif packet.type == RPLC_TYPE.AUTO_BURN_RATE then
|
||||
-- automatic control requested a new burn rate
|
||||
if (packet.length == 3) and (type(packet.data[1]) == "number") and (type(packet.data[3]) == "number") then
|
||||
local ack = AUTO_ACK.FAIL
|
||||
@@ -898,9 +898,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
else
|
||||
log.debug("discarding RPLC packet before linked")
|
||||
end
|
||||
elseif protocol == PROTOCOLS.SCADA_MGMT then
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
if self.linked then
|
||||
if packet.type == SCADA_MGMT_TYPES.ESTABLISH then
|
||||
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
|
||||
-- link request confirmation
|
||||
if packet.length == 1 then
|
||||
log.debug("received unsolicited establish response")
|
||||
@@ -933,7 +933,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
else
|
||||
log.debug("SCADA_MGMT establish packet length mismatch")
|
||||
end
|
||||
elseif packet.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
|
||||
elseif packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive request received, echo back
|
||||
if packet.length == 1 and type(packet.data[1]) == "number" then
|
||||
local timestamp = packet.data[1]
|
||||
@@ -949,7 +949,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
else
|
||||
log.debug("SCADA_MGMT keep alive packet length/type mismatch")
|
||||
end
|
||||
elseif packet.type == SCADA_MGMT_TYPES.CLOSE then
|
||||
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
|
||||
-- handle session close
|
||||
conn_watchdog.cancel()
|
||||
public.unlink()
|
||||
@@ -958,7 +958,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
else
|
||||
log.warning("received unsupported SCADA_MGMT packet type " .. packet.type)
|
||||
end
|
||||
elseif packet.type == SCADA_MGMT_TYPES.ESTABLISH then
|
||||
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
|
||||
-- link request confirmation
|
||||
if packet.length == 1 then
|
||||
local est_ack = packet.data[1]
|
||||
|
||||
Reference in New Issue