#118 refactoring of comms types
This commit is contained in:
@@ -7,12 +7,12 @@ local svqtypes = require("supervisor.session.svqtypes")
|
||||
|
||||
local coordinator = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local SCADA_CRDN_TYPES = comms.SCADA_CRDN_TYPES
|
||||
local UNIT_COMMANDS = comms.UNIT_COMMANDS
|
||||
local FAC_COMMANDS = comms.FAC_COMMANDS
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
||||
local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
|
||||
local UNIT_COMMAND = comms.UNIT_COMMAND
|
||||
local FAC_COMMAND = comms.FAC_COMMAND
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
|
||||
local SV_Q_CMDS = svqtypes.SV_Q_CMDS
|
||||
local SV_Q_DATA = svqtypes.SV_Q_DATA
|
||||
@@ -90,28 +90,28 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
end
|
||||
|
||||
-- send a CRDN packet
|
||||
---@param msg_type SCADA_CRDN_TYPES
|
||||
---@param msg_type SCADA_CRDN_TYPE
|
||||
---@param msg table
|
||||
local function _send(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local c_pkt = comms.crdn_packet()
|
||||
|
||||
c_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_CRDN, c_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_CRDN, c_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send a SCADA management packet
|
||||
---@param msg_type SCADA_MGMT_TYPES
|
||||
---@param msg_type SCADA_MGMT_TYPE
|
||||
---@param msg table
|
||||
local function _send_mgmt(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
@@ -126,12 +126,12 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
unit_builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.INITIAL_BUILDS, { facility.get_build(), unit_builds })
|
||||
_send(SCADA_CRDN_TYPE.INITIAL_BUILDS, { facility.get_build(), unit_builds })
|
||||
end
|
||||
|
||||
-- send facility builds
|
||||
local function _send_fac_builds()
|
||||
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build() })
|
||||
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build() })
|
||||
end
|
||||
|
||||
-- send unit builds
|
||||
@@ -143,7 +143,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
|
||||
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
|
||||
end
|
||||
|
||||
-- send facility status
|
||||
@@ -153,7 +153,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
facility.get_rtu_statuses()
|
||||
}
|
||||
|
||||
_send(SCADA_CRDN_TYPES.FAC_STATUS, status)
|
||||
_send(SCADA_CRDN_TYPE.FAC_STATUS, status)
|
||||
end
|
||||
|
||||
-- send unit statuses
|
||||
@@ -172,7 +172,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
}
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.UNIT_STATUSES, status)
|
||||
_send(SCADA_CRDN_TYPE.UNIT_STATUSES, status)
|
||||
end
|
||||
|
||||
-- handle a packet
|
||||
@@ -192,8 +192,8 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
self.conn_watchdog.feed()
|
||||
|
||||
-- process packet
|
||||
if pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive reply
|
||||
if pkt.length == 2 then
|
||||
local srv_start = pkt.data[1]
|
||||
@@ -210,30 +210,30 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
else
|
||||
log.debug(log_header .. "SCADA keep alive packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
|
||||
-- close the session
|
||||
_close()
|
||||
else
|
||||
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_CRDN then
|
||||
if pkt.type == SCADA_CRDN_TYPES.INITIAL_BUILDS then
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_CRDN then
|
||||
if pkt.type == SCADA_CRDN_TYPE.INITIAL_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.builds = true
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
|
||||
elseif pkt.type == SCADA_CRDN_TYPE.FAC_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.fac_builds = true
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.FAC_CMD then
|
||||
elseif pkt.type == SCADA_CRDN_TYPE.FAC_CMD then
|
||||
if pkt.length >= 1 then
|
||||
local cmd = pkt.data[1]
|
||||
|
||||
if cmd == FAC_COMMANDS.SCRAM_ALL then
|
||||
if cmd == FAC_COMMAND.SCRAM_ALL then
|
||||
facility.scram_all()
|
||||
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
|
||||
elseif cmd == FAC_COMMANDS.STOP then
|
||||
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
|
||||
elseif cmd == FAC_COMMAND.STOP then
|
||||
facility.auto_stop()
|
||||
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
|
||||
elseif cmd == FAC_COMMANDS.START then
|
||||
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
|
||||
elseif cmd == FAC_COMMAND.START then
|
||||
if pkt.length == 6 then
|
||||
---@type coord_auto_config
|
||||
local config = {
|
||||
@@ -244,23 +244,23 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
limits = pkt.data[6]
|
||||
}
|
||||
|
||||
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
|
||||
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
|
||||
else
|
||||
log.debug(log_header .. "CRDN auto start (with configuration) packet length mismatch")
|
||||
end
|
||||
elseif cmd == FAC_COMMANDS.ACK_ALL_ALARMS then
|
||||
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
|
||||
facility.ack_all()
|
||||
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
|
||||
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
|
||||
else
|
||||
log.debug(log_header .. "CRDN facility command unknown")
|
||||
end
|
||||
else
|
||||
log.debug(log_header .. "CRDN facility command packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.UNIT_BUILDS then
|
||||
elseif pkt.type == SCADA_CRDN_TYPE.UNIT_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.unit_builds = true
|
||||
elseif pkt.type == SCADA_CRDN_TYPES.UNIT_CMD then
|
||||
elseif pkt.type == SCADA_CRDN_TYPE.UNIT_CMD then
|
||||
if pkt.length >= 2 then
|
||||
-- get command and unit id
|
||||
local cmd = pkt.data[1]
|
||||
@@ -273,43 +273,43 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
if util.is_int(uid) and uid > 0 and uid <= #self.units then
|
||||
local unit = self.units[uid] ---@type reactor_unit
|
||||
|
||||
if cmd == UNIT_COMMANDS.START then
|
||||
if cmd == UNIT_COMMAND.START then
|
||||
self.out_q.push_data(SV_Q_DATA.START, data)
|
||||
elseif cmd == UNIT_COMMANDS.SCRAM then
|
||||
elseif cmd == UNIT_COMMAND.SCRAM then
|
||||
self.out_q.push_data(SV_Q_DATA.SCRAM, data)
|
||||
elseif cmd == UNIT_COMMANDS.RESET_RPS then
|
||||
elseif cmd == UNIT_COMMAND.RESET_RPS then
|
||||
self.out_q.push_data(SV_Q_DATA.RESET_RPS, data)
|
||||
elseif cmd == UNIT_COMMANDS.SET_BURN then
|
||||
elseif cmd == UNIT_COMMAND.SET_BURN then
|
||||
if pkt.length == 3 then
|
||||
self.out_q.push_data(SV_Q_DATA.SET_BURN, data)
|
||||
else
|
||||
log.debug(log_header .. "CRDN unit command burn rate missing option")
|
||||
end
|
||||
elseif cmd == UNIT_COMMANDS.SET_WASTE then
|
||||
elseif cmd == UNIT_COMMAND.SET_WASTE then
|
||||
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] > 0) and (pkt.data[3] <= 4) then
|
||||
unit.set_waste(pkt.data[3])
|
||||
else
|
||||
log.debug(log_header .. "CRDN unit command set waste missing option")
|
||||
end
|
||||
elseif cmd == UNIT_COMMANDS.ACK_ALL_ALARMS then
|
||||
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
|
||||
unit.ack_all()
|
||||
_send(SCADA_CRDN_TYPES.UNIT_CMD, { cmd, uid, true })
|
||||
elseif cmd == UNIT_COMMANDS.ACK_ALARM then
|
||||
_send(SCADA_CRDN_TYPE.UNIT_CMD, { cmd, uid, true })
|
||||
elseif cmd == UNIT_COMMAND.ACK_ALARM then
|
||||
if pkt.length == 3 then
|
||||
unit.ack_alarm(pkt.data[3])
|
||||
else
|
||||
log.debug(log_header .. "CRDN unit command ack alarm missing alarm id")
|
||||
end
|
||||
elseif cmd == UNIT_COMMANDS.RESET_ALARM then
|
||||
elseif cmd == UNIT_COMMAND.RESET_ALARM then
|
||||
if pkt.length == 3 then
|
||||
unit.reset_alarm(pkt.data[3])
|
||||
else
|
||||
log.debug(log_header .. "CRDN unit command reset alarm missing alarm id")
|
||||
end
|
||||
elseif cmd == UNIT_COMMANDS.SET_GROUP then
|
||||
elseif cmd == UNIT_COMMAND.SET_GROUP then
|
||||
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] >= 0) and (pkt.data[3] <= 4) then
|
||||
facility.set_group(unit.get_id(), pkt.data[3])
|
||||
_send(SCADA_CRDN_TYPES.UNIT_CMD, { cmd, uid, pkt.data[3] })
|
||||
_send(SCADA_CRDN_TYPE.UNIT_CMD, { cmd, uid, pkt.data[3] })
|
||||
else
|
||||
log.debug(log_header .. "CRDN unit command set group missing group id")
|
||||
end
|
||||
@@ -342,7 +342,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
-- close the connection
|
||||
function public.close()
|
||||
_close()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
|
||||
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
|
||||
println("connection to coordinator " .. id .. " closed by server")
|
||||
log.info(log_header .. "session closed by server")
|
||||
end
|
||||
@@ -373,7 +373,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
|
||||
if cmd.key == CRD_S_DATA.CMD_ACK then
|
||||
local ack = cmd.val ---@type coord_ack
|
||||
_send(SCADA_CRDN_TYPES.UNIT_CMD, { ack.cmd, ack.unit, ack.ack })
|
||||
_send(SCADA_CRDN_TYPE.UNIT_CMD, { ack.cmd, ack.unit, ack.ack })
|
||||
elseif cmd.key == CRD_S_DATA.RESEND_PLC_BUILD then
|
||||
-- re-send PLC build
|
||||
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
|
||||
@@ -386,7 +386,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
local unit = self.units[unit_id] ---@type reactor_unit
|
||||
builds[unit_id] = unit.get_build(true, false, false)
|
||||
|
||||
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
|
||||
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
|
||||
elseif cmd.key == CRD_S_DATA.RESEND_RTU_BUILD then
|
||||
local unit_id = cmd.val.unit
|
||||
if unit_id > 0 then
|
||||
@@ -398,16 +398,16 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
local builds = {}
|
||||
|
||||
local unit = self.units[unit_id] ---@type reactor_unit
|
||||
builds[unit_id] = unit.get_build(false, cmd.val.type == RTU_UNIT_TYPES.BOILER_VALVE, cmd.val.type == RTU_UNIT_TYPES.TURBINE_VALVE)
|
||||
builds[unit_id] = unit.get_build(false, cmd.val.type == RTU_UNIT_TYPE.BOILER_VALVE, cmd.val.type == RTU_UNIT_TYPE.TURBINE_VALVE)
|
||||
|
||||
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
|
||||
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
|
||||
else
|
||||
-- re-send facility RTU builds
|
||||
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
|
||||
self.retry_times.f_builds_packet = util.time() + PARTIAL_RETRY_PERIOD
|
||||
self.acks.fac_builds = false
|
||||
|
||||
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build(cmd.val.type == RTU_UNIT_TYPES.IMATRIX) })
|
||||
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build(cmd.val.type == RTU_UNIT_TYPE.IMATRIX) })
|
||||
end
|
||||
else
|
||||
log.warning(log_header .. "unsupported data command received in in_queue (this is a bug)")
|
||||
@@ -441,7 +441,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
|
||||
|
||||
periodics.keep_alive = periodics.keep_alive + elapsed
|
||||
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
|
||||
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
|
||||
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
|
||||
periodics.keep_alive = 0
|
||||
end
|
||||
|
||||
|
||||
@@ -8,12 +8,12 @@ local svqtypes = require("supervisor.session.svqtypes")
|
||||
|
||||
local plc = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local RPLC_TYPES = comms.RPLC_TYPES
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local RPLC_TYPE = comms.RPLC_TYPE
|
||||
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
||||
local PLC_AUTO_ACK = comms.PLC_AUTO_ACK
|
||||
|
||||
local UNIT_COMMANDS = comms.UNIT_COMMANDS
|
||||
local UNIT_COMMAND = comms.UNIT_COMMAND
|
||||
|
||||
local print = util.print
|
||||
local println = util.println
|
||||
@@ -244,28 +244,28 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
end
|
||||
|
||||
-- send an RPLC packet
|
||||
---@param msg_type RPLC_TYPES
|
||||
---@param msg_type RPLC_TYPE
|
||||
---@param msg table
|
||||
local function _send(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local r_pkt = comms.rplc_packet()
|
||||
|
||||
r_pkt.make(for_reactor, msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.RPLC, r_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send a SCADA management packet
|
||||
---@param msg_type SCADA_MGMT_TYPES
|
||||
---@param msg_type SCADA_MGMT_TYPE
|
||||
---@param msg table
|
||||
local function _send_mgmt(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
@@ -297,7 +297,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
end
|
||||
|
||||
-- process packet
|
||||
if pkt.scada_frame.protocol() == PROTOCOLS.RPLC then
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.RPLC then
|
||||
-- check reactor ID
|
||||
if pkt.id ~= for_reactor then
|
||||
log.warning(log_header .. "RPLC packet with ID not matching reactor ID: reactor " .. self.for_reactor .. " != " .. pkt.id)
|
||||
@@ -308,7 +308,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
self.plc_conn_watchdog.feed()
|
||||
|
||||
-- handle packet by type
|
||||
if pkt.type == RPLC_TYPES.STATUS then
|
||||
if pkt.type == RPLC_TYPE.STATUS then
|
||||
-- status packet received, update data
|
||||
if pkt.length >= 5 then
|
||||
self.sDB.last_status_update = pkt.data[1]
|
||||
@@ -335,7 +335,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "RPLC status packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.MEK_STRUCT then
|
||||
elseif pkt.type == RPLC_TYPE.MEK_STRUCT then
|
||||
-- received reactor structure, record it
|
||||
if pkt.length == 14 then
|
||||
local status = pcall(_copy_struct, pkt.data)
|
||||
@@ -350,7 +350,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "RPLC struct packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.MEK_BURN_RATE then
|
||||
elseif pkt.type == RPLC_TYPE.MEK_BURN_RATE then
|
||||
-- burn rate acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if ack then
|
||||
@@ -362,10 +362,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
-- send acknowledgement to coordinator
|
||||
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
|
||||
unit = self.for_reactor,
|
||||
cmd = UNIT_COMMANDS.SET_BURN,
|
||||
cmd = UNIT_COMMAND.SET_BURN,
|
||||
ack = ack
|
||||
})
|
||||
elseif pkt.type == RPLC_TYPES.RPS_ENABLE then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_ENABLE then
|
||||
-- enable acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if ack then
|
||||
@@ -377,10 +377,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
-- send acknowledgement to coordinator
|
||||
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
|
||||
unit = self.for_reactor,
|
||||
cmd = UNIT_COMMANDS.START,
|
||||
cmd = UNIT_COMMAND.START,
|
||||
ack = ack
|
||||
})
|
||||
elseif pkt.type == RPLC_TYPES.RPS_SCRAM then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_SCRAM then
|
||||
-- manual SCRAM acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if ack then
|
||||
@@ -393,10 +393,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
-- send acknowledgement to coordinator
|
||||
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
|
||||
unit = self.for_reactor,
|
||||
cmd = UNIT_COMMANDS.SCRAM,
|
||||
cmd = UNIT_COMMAND.SCRAM,
|
||||
ack = ack
|
||||
})
|
||||
elseif pkt.type == RPLC_TYPES.RPS_ASCRAM then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_ASCRAM then
|
||||
-- automatic SCRAM acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if ack then
|
||||
@@ -405,7 +405,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
elseif ack == false then
|
||||
log.debug(log_header .. " automatic SCRAM failed!")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.RPS_STATUS then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_STATUS then
|
||||
-- RPS status packet received, copy data
|
||||
if pkt.length == 14 then
|
||||
local status = pcall(_copy_rps_status, pkt.data)
|
||||
@@ -418,7 +418,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "RPLC RPS status packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.RPS_ALARM then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_ALARM then
|
||||
-- RPS alarm
|
||||
if pkt.length == 13 then
|
||||
local status = pcall(_copy_rps_status, { true, table.unpack(pkt.data) })
|
||||
@@ -431,7 +431,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "RPLC RPS alarm packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.RPS_RESET then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_RESET then
|
||||
-- RPS reset acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if ack then
|
||||
@@ -445,16 +445,16 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
-- send acknowledgement to coordinator
|
||||
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
|
||||
unit = self.for_reactor,
|
||||
cmd = UNIT_COMMANDS.RESET_RPS,
|
||||
cmd = UNIT_COMMAND.RESET_RPS,
|
||||
ack = ack
|
||||
})
|
||||
elseif pkt.type == RPLC_TYPES.RPS_AUTO_RESET then
|
||||
elseif pkt.type == RPLC_TYPE.RPS_AUTO_RESET then
|
||||
-- RPS auto control reset acknowledgement
|
||||
local ack = _get_ack(pkt)
|
||||
if not ack then
|
||||
log.debug(log_header .. "RPS auto reset failed")
|
||||
end
|
||||
elseif pkt.type == RPLC_TYPES.AUTO_BURN_RATE then
|
||||
elseif pkt.type == RPLC_TYPE.AUTO_BURN_RATE then
|
||||
if pkt.length == 1 then
|
||||
local ack = pkt.data[1]
|
||||
|
||||
@@ -473,8 +473,8 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "handler received unsupported RPLC packet type " .. pkt.type)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive reply
|
||||
if pkt.length == 2 then
|
||||
local srv_start = pkt.data[1]
|
||||
@@ -491,7 +491,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
else
|
||||
log.debug(log_header .. "SCADA keep alive packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
|
||||
-- close the session
|
||||
_close()
|
||||
else
|
||||
@@ -575,7 +575,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
-- close the connection
|
||||
function public.close()
|
||||
_close()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
|
||||
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
|
||||
println("connection to reactor " .. self.for_reactor .. " PLC closed by server")
|
||||
log.info(log_header .. "session closed by server")
|
||||
end
|
||||
@@ -604,27 +604,27 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
if cmd == PLC_S_CMDS.ENABLE then
|
||||
-- enable reactor
|
||||
if not self.auto_lock then
|
||||
_send(RPLC_TYPES.RPS_ENABLE, {})
|
||||
_send(RPLC_TYPE.RPS_ENABLE, {})
|
||||
end
|
||||
elseif cmd == PLC_S_CMDS.SCRAM then
|
||||
-- SCRAM reactor
|
||||
self.acks.scram = false
|
||||
self.retry_times.scram_req = util.time() + INITIAL_WAIT
|
||||
_send(RPLC_TYPES.RPS_SCRAM, {})
|
||||
_send(RPLC_TYPE.RPS_SCRAM, {})
|
||||
elseif cmd == PLC_S_CMDS.ASCRAM then
|
||||
-- SCRAM reactor
|
||||
self.acks.ascram = false
|
||||
self.retry_times.ascram_req = util.time() + INITIAL_WAIT
|
||||
_send(RPLC_TYPES.RPS_ASCRAM, {})
|
||||
_send(RPLC_TYPE.RPS_ASCRAM, {})
|
||||
elseif cmd == PLC_S_CMDS.RPS_RESET then
|
||||
-- reset RPS
|
||||
self.acks.ascram = true
|
||||
self.acks.rps_reset = false
|
||||
self.retry_times.rps_reset_req = util.time() + INITIAL_WAIT
|
||||
_send(RPLC_TYPES.RPS_RESET, {})
|
||||
_send(RPLC_TYPE.RPS_RESET, {})
|
||||
elseif cmd == PLC_S_CMDS.RPS_AUTO_RESET then
|
||||
if self.sDB.rps_status.automatic or self.sDB.rps_status.timeout then
|
||||
_send(RPLC_TYPES.RPS_AUTO_RESET, {})
|
||||
_send(RPLC_TYPE.RPS_AUTO_RESET, {})
|
||||
end
|
||||
else
|
||||
log.warning(log_header .. "unsupported command received in in_queue (this is a bug)")
|
||||
@@ -642,7 +642,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
self.ramping_rate = false
|
||||
self.acks.burn_rate = false
|
||||
self.retry_times.burn_rate_req = util.time() + INITIAL_WAIT
|
||||
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
end
|
||||
end
|
||||
elseif cmd.key == PLC_S_DATA.RAMP_BURN_RATE then
|
||||
@@ -655,7 +655,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
self.ramping_rate = true
|
||||
self.acks.burn_rate = false
|
||||
self.retry_times.burn_rate_req = util.time() + INITIAL_WAIT
|
||||
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
end
|
||||
end
|
||||
elseif cmd.key == PLC_S_DATA.AUTO_BURN_RATE then
|
||||
@@ -670,7 +670,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
self.acks.burn_rate = not self.ramping_rate
|
||||
self.retry_times.burn_rate_req = util.time() + INITIAL_AUTO_WAIT
|
||||
|
||||
_send(RPLC_TYPES.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
|
||||
_send(RPLC_TYPE.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
|
||||
end
|
||||
end
|
||||
else
|
||||
@@ -705,7 +705,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
periodics.keep_alive = periodics.keep_alive + elapsed
|
||||
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
|
||||
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
|
||||
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
|
||||
periodics.keep_alive = 0
|
||||
end
|
||||
|
||||
@@ -722,7 +722,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
if not self.received_struct then
|
||||
if rtimes.struct_req - util.time() <= 0 then
|
||||
_send(RPLC_TYPES.MEK_STRUCT, {})
|
||||
_send(RPLC_TYPE.MEK_STRUCT, {})
|
||||
rtimes.struct_req = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
@@ -731,7 +731,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
if not self.received_status_cache then
|
||||
if rtimes.status_req - util.time() <= 0 then
|
||||
_send(RPLC_TYPES.MEK_STATUS, {})
|
||||
_send(RPLC_TYPE.MEK_STATUS, {})
|
||||
rtimes.status_req = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
@@ -742,13 +742,13 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
if rtimes.burn_rate_req - util.time() <= 0 then
|
||||
if self.auto_cmd_token > 0 then
|
||||
if self.auto_lock then
|
||||
_send(RPLC_TYPES.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
|
||||
_send(RPLC_TYPE.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
|
||||
else
|
||||
-- would have been an auto command, but disengaged, so stop retrying
|
||||
self.acks.burn_rate = true
|
||||
end
|
||||
elseif not self.auto_lock then
|
||||
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
|
||||
else
|
||||
-- shouldn't be in this state, just pretend it was acknowledged
|
||||
self.acks.burn_rate = true
|
||||
@@ -763,7 +763,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
if not self.acks.scram then
|
||||
if rtimes.scram_req - util.time() <= 0 then
|
||||
_send(RPLC_TYPES.RPS_SCRAM, {})
|
||||
_send(RPLC_TYPE.RPS_SCRAM, {})
|
||||
rtimes.scram_req = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
@@ -772,7 +772,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
if not self.acks.ascram then
|
||||
if rtimes.ascram_req - util.time() <= 0 then
|
||||
_send(RPLC_TYPES.RPS_ASCRAM, {})
|
||||
_send(RPLC_TYPE.RPS_ASCRAM, {})
|
||||
rtimes.ascram_req = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
@@ -781,7 +781,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
|
||||
|
||||
if not self.acks.rps_reset then
|
||||
if rtimes.rps_reset_req - util.time() <= 0 then
|
||||
_send(RPLC_TYPES.RPS_RESET, {})
|
||||
_send(RPLC_TYPE.RPS_RESET, {})
|
||||
rtimes.rps_reset_req = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
|
||||
@@ -18,9 +18,9 @@ local svrs_turbinev = require("supervisor.session.rtu.turbinev")
|
||||
|
||||
local rtu = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
|
||||
local print = util.print
|
||||
local println = util.println
|
||||
@@ -99,7 +99,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
advert_validator.assert_type_int(unit_advert.index)
|
||||
advert_validator.assert_type_int(unit_advert.reactor)
|
||||
|
||||
if u_type == RTU_UNIT_TYPES.REDSTONE then
|
||||
if u_type == RTU_UNIT_TYPE.REDSTONE then
|
||||
advert_validator.assert_type_table(unit_advert.rsio)
|
||||
end
|
||||
|
||||
@@ -124,19 +124,19 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
if unit_advert.reactor > 0 then
|
||||
local target_unit = self.fac_units[unit_advert.reactor] ---@type reactor_unit
|
||||
|
||||
if u_type == RTU_UNIT_TYPES.REDSTONE then
|
||||
if u_type == RTU_UNIT_TYPE.REDSTONE then
|
||||
-- redstone
|
||||
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then target_unit.add_redstone(unit) end
|
||||
elseif u_type == RTU_UNIT_TYPES.BOILER_VALVE then
|
||||
elseif u_type == RTU_UNIT_TYPE.BOILER_VALVE then
|
||||
-- boiler (Mekanism 10.1+)
|
||||
unit = svrs_boilerv.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then target_unit.add_boiler(unit) end
|
||||
elseif u_type == RTU_UNIT_TYPES.TURBINE_VALVE then
|
||||
elseif u_type == RTU_UNIT_TYPE.TURBINE_VALVE then
|
||||
-- turbine (Mekanism 10.1+)
|
||||
unit = svrs_turbinev.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then target_unit.add_turbine(unit) end
|
||||
elseif u_type == RTU_UNIT_TYPES.ENV_DETECTOR then
|
||||
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
|
||||
-- environment detector
|
||||
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then target_unit.add_envd(unit) end
|
||||
@@ -144,21 +144,21 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
log.error(util.c(log_header, "bad advertisement: encountered unsupported reactor-specific RTU type ", type_string))
|
||||
end
|
||||
else
|
||||
if u_type == RTU_UNIT_TYPES.REDSTONE then
|
||||
if u_type == RTU_UNIT_TYPE.REDSTONE then
|
||||
-- redstone
|
||||
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then facility.add_redstone(unit) end
|
||||
elseif u_type == RTU_UNIT_TYPES.IMATRIX then
|
||||
elseif u_type == RTU_UNIT_TYPE.IMATRIX then
|
||||
-- induction matrix
|
||||
unit = svrs_imatrix.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then facility.add_imatrix(unit) end
|
||||
elseif u_type == RTU_UNIT_TYPES.SPS then
|
||||
elseif u_type == RTU_UNIT_TYPE.SPS then
|
||||
-- super-critical phase shifter
|
||||
unit = svrs_sps.new(id, i, unit_advert, self.modbus_q)
|
||||
elseif u_type == RTU_UNIT_TYPES.SNA then
|
||||
elseif u_type == RTU_UNIT_TYPE.SNA then
|
||||
-- solar neutron activator
|
||||
unit = svrs_sna.new(id, i, unit_advert, self.modbus_q)
|
||||
elseif u_type == RTU_UNIT_TYPES.ENV_DETECTOR then
|
||||
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
|
||||
-- environment detector
|
||||
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
|
||||
if type(unit) ~= "nil" then facility.add_envd(unit) end
|
||||
@@ -194,21 +194,21 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
local function _send_modbus(m_pkt)
|
||||
local s_pkt = comms.scada_packet()
|
||||
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.MODBUS_TCP, m_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send a SCADA management packet
|
||||
---@param msg_type SCADA_MGMT_TYPES
|
||||
---@param msg_type SCADA_MGMT_TYPE
|
||||
---@param msg table
|
||||
local function _send_mgmt(msg_type, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.out_q.push_packet(s_pkt)
|
||||
self.seq_num = self.seq_num + 1
|
||||
@@ -231,15 +231,15 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
self.rtu_conn_watchdog.feed()
|
||||
|
||||
-- process packet
|
||||
if pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
|
||||
if self.units[pkt.unit_id] ~= nil then
|
||||
local unit = self.units[pkt.unit_id] ---@type unit_session
|
||||
---@diagnostic disable-next-line: param-type-mismatch
|
||||
unit.handle_packet(pkt)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
-- handle management packet
|
||||
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
|
||||
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive reply
|
||||
if pkt.length == 2 then
|
||||
local srv_start = pkt.data[1]
|
||||
@@ -256,10 +256,10 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
else
|
||||
log.debug(log_header .. "SCADA keep alive packet length mismatch")
|
||||
end
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
|
||||
-- close the session
|
||||
_close()
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.RTU_ADVERT then
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.RTU_ADVERT then
|
||||
-- RTU unit advertisement
|
||||
log.debug(log_header .. "received updated advertisement")
|
||||
|
||||
@@ -269,7 +269,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
|
||||
-- handle advertisement; this will re-create all unit sub-sessions
|
||||
_handle_advertisement()
|
||||
elseif pkt.type == SCADA_MGMT_TYPES.RTU_DEV_REMOUNT then
|
||||
elseif pkt.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT then
|
||||
if pkt.length == 1 then
|
||||
local unit_id = pkt.data[1]
|
||||
if self.units[unit_id] ~= nil then
|
||||
@@ -299,7 +299,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
-- close the connection
|
||||
function public.close()
|
||||
_close()
|
||||
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
|
||||
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
|
||||
println(log_header .. "connection to RTU closed by server")
|
||||
log.info(log_header .. "session closed by server")
|
||||
end
|
||||
@@ -365,7 +365,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
|
||||
|
||||
periodics.keep_alive = periodics.keep_alive + elapsed
|
||||
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
|
||||
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
|
||||
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
|
||||
periodics.keep_alive = 0
|
||||
end
|
||||
|
||||
|
||||
@@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local boilerv = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local TXN_TYPES = {
|
||||
@@ -38,7 +38,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue RTU unit message out queue
|
||||
function boilerv.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.BOILER_VALVE then
|
||||
if advert.type ~= RTU_UNIT_TYPE.BOILER_VALVE then
|
||||
log.error("attempt to instantiate boilerv RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local envd = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local TXN_TYPES = {
|
||||
@@ -29,7 +29,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue
|
||||
function envd.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.ENV_DETECTOR then
|
||||
if advert.type ~= RTU_UNIT_TYPE.ENV_DETECTOR then
|
||||
log.error("attempt to instantiate envd RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local imatrix = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local TXN_TYPES = {
|
||||
@@ -38,7 +38,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue RTU unit message out queue
|
||||
function imatrix.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.IMATRIX then
|
||||
if advert.type ~= RTU_UNIT_TYPE.IMATRIX then
|
||||
log.error("attempt to instantiate imatrix RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -9,7 +9,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local redstone = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local IO_PORT = rsio.IO
|
||||
@@ -53,7 +53,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue
|
||||
function redstone.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.REDSTONE then
|
||||
if advert.type ~= RTU_UNIT_TYPE.REDSTONE then
|
||||
log.error("attempt to instantiate redstone RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local sna = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local TXN_TYPES = {
|
||||
@@ -35,7 +35,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue RTU unit message out queue
|
||||
function sna.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.SNA then
|
||||
if advert.type ~= RTU_UNIT_TYPE.SNA then
|
||||
log.error("attempt to instantiate sna RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local sps = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local TXN_TYPES = {
|
||||
@@ -38,7 +38,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue RTU unit message out queue
|
||||
function sps.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.SPS then
|
||||
if advert.type ~= RTU_UNIT_TYPE.SPS then
|
||||
log.error("attempt to instantiate sps RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -9,7 +9,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local turbinev = {}
|
||||
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
|
||||
local DUMPING_MODE = types.DUMPING_MODE
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
@@ -50,7 +50,7 @@ local PERIODICS = {
|
||||
---@param out_queue mqueue RTU unit message out queue
|
||||
function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
-- type check
|
||||
if advert.type ~= RTU_UNIT_TYPES.TURBINE_VALVE then
|
||||
if advert.type ~= RTU_UNIT_TYPE.TURBINE_VALVE then
|
||||
log.error("attempt to instantiate turbinev RTU for type '" .. advert.type .. "'. this is a bug.")
|
||||
return nil
|
||||
end
|
||||
|
||||
@@ -8,7 +8,7 @@ local txnctrl = require("supervisor.session.rtu.txnctrl")
|
||||
|
||||
local unit_session = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
local MODBUS_EXCODE = types.MODBUS_EXCODE
|
||||
|
||||
@@ -72,7 +72,7 @@ function unit_session.new(session_id, unit_id, advert, out_queue, log_tag, txn_t
|
||||
---@param m_pkt modbus_frame MODBUS packet
|
||||
---@return integer|false txn_type, integer txn_id transaction type or false on error/busy, transaction ID
|
||||
function protected.try_resolve(m_pkt)
|
||||
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
if m_pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
|
||||
if m_pkt.unit_id == self.unit_id then
|
||||
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
|
||||
local txn_tag = " (" .. util.strval(self.txn_tags[txn_type]) .. ")"
|
||||
|
||||
Reference in New Issue