#308 integrated new settings file with supervisor
This commit is contained in:
@@ -2,8 +2,6 @@ local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("supervisor.config")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local supervisor = {}
|
||||
@@ -13,6 +11,77 @@ local DEVICE_TYPE = comms.DEVICE_TYPE
|
||||
local ESTABLISH_ACK = comms.ESTABLISH_ACK
|
||||
local MGMT_TYPE = comms.MGMT_TYPE
|
||||
|
||||
---@type svr_config
|
||||
local config = {}
|
||||
|
||||
supervisor.config = config
|
||||
|
||||
-- load the supervisor configuration
|
||||
function supervisor.load_config()
|
||||
if not settings.load("/supervisor.settings") then return false end
|
||||
|
||||
config.UnitCount = settings.get("UnitCount")
|
||||
config.CoolingConfig = settings.get("CoolingConfig")
|
||||
config.FacilityTankMode = settings.get("FacilityTankMode")
|
||||
config.FacilityTankDefs = settings.get("FacilityTankDefs")
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.PLC_Channel = settings.get("PLC_Channel")
|
||||
config.RTU_Channel = settings.get("RTU_Channel")
|
||||
config.CRD_Channel = settings.get("CRD_Channel")
|
||||
config.PKT_Channel = settings.get("PKT_Channel")
|
||||
|
||||
config.PLC_Timeout = settings.get("PLC_Timeout")
|
||||
config.RTU_Timeout = settings.get("RTU_Timeout")
|
||||
config.CRD_Timeout = settings.get("CRD_Timeout")
|
||||
config.PKT_Timeout = settings.get("PKT_Timeout")
|
||||
|
||||
config.TrustedRange = settings.get("TrustedRange")
|
||||
config.AuthKey = settings.get("AuthKey")
|
||||
|
||||
config.LogMode = settings.get("LogMode")
|
||||
config.LogPath = settings.get("LogPath")
|
||||
config.LogDebug = settings.get("LogDebug")
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_type_int(config.UnitCount)
|
||||
cfv.assert_range(config.UnitCount, 1, 4)
|
||||
|
||||
cfv.assert_type_table(config.CoolingConfig)
|
||||
cfv.assert_type_table(config.FacilityTankDefs)
|
||||
cfv.assert_type_int(config.FacilityTankMode)
|
||||
cfv.assert_range(config.FacilityTankMode, 0, 8)
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.PLC_Channel)
|
||||
cfv.assert_channel(config.RTU_Channel)
|
||||
cfv.assert_channel(config.CRD_Channel)
|
||||
cfv.assert_channel(config.PKT_Channel)
|
||||
|
||||
cfv.assert_type_num(config.PLC_Timeout)
|
||||
cfv.assert_min(config.PLC_Timeout, 2)
|
||||
cfv.assert_type_num(config.RTU_Timeout)
|
||||
cfv.assert_min(config.RTU_Timeout, 2)
|
||||
cfv.assert_type_num(config.CRD_Timeout)
|
||||
cfv.assert_min(config.CRD_Timeout, 2)
|
||||
cfv.assert_type_num(config.PKT_Timeout)
|
||||
cfv.assert_min(config.PKT_Timeout, 2)
|
||||
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
|
||||
if type(config.AuthKey) == "string" then
|
||||
local len = string.len(config.AuthKey)
|
||||
cfv.assert_eq(len == 0 or len >= 8, true)
|
||||
end
|
||||
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
return cfv.valid()
|
||||
end
|
||||
|
||||
-- supervisory controller communications
|
||||
---@nodiscard
|
||||
---@param _version string supervisor version
|
||||
@@ -23,32 +92,23 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
-- print a log message to the terminal as long as the UI isn't running
|
||||
local function println(message) if not fp_ok then util.println_ts(message) end end
|
||||
|
||||
-- channel list from config
|
||||
local svr_channel = config.SVR_CHANNEL
|
||||
local plc_channel = config.PLC_CHANNEL
|
||||
local rtu_channel = config.RTU_CHANNEL
|
||||
local crd_channel = config.CRD_CHANNEL
|
||||
local pkt_channel = config.PKT_CHANNEL
|
||||
|
||||
-- configuration data
|
||||
local num_reactors = config.NUM_REACTORS
|
||||
---@class sv_cooling_conf
|
||||
local cooling_conf = { r_cool = config.REACTOR_COOLING, fac_tank_mode = config.FAC_TANK_MODE, fac_tank_defs = config.FAC_TANK_DEFS }
|
||||
local cooling_conf = { r_cool = config.CoolingConfig, fac_tank_mode = config.FacilityTankMode, fac_tank_defs = config.FacilityTankDefs }
|
||||
|
||||
local self = {
|
||||
last_est_acks = {}
|
||||
}
|
||||
|
||||
comms.set_trusted_range(config.TRUSTED_RANGE)
|
||||
comms.set_trusted_range(config.TrustedRange)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- configure modem channels
|
||||
nic.closeAll()
|
||||
nic.open(svr_channel)
|
||||
nic.open(config.SVR_Channel)
|
||||
|
||||
-- pass modem, status, and config data to svsessions
|
||||
svsessions.init(nic, fp_ok, num_reactors, cooling_conf)
|
||||
svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
|
||||
-- send an establish request response
|
||||
---@param packet scada_packet
|
||||
@@ -61,7 +121,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
m_pkt.make(MGMT_TYPE.ESTABLISH, { ack, data })
|
||||
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
nic.transmit(packet.remote_channel(), svr_channel, s_pkt)
|
||||
nic.transmit(packet.remote_channel(), config.SVR_Channel, s_pkt)
|
||||
self.last_est_acks[packet.src_addr()] = ack
|
||||
end
|
||||
|
||||
@@ -124,9 +184,9 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
if l_chan ~= svr_channel then
|
||||
if l_chan ~= config.SVR_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == plc_channel then
|
||||
elseif r_chan == config.PLC_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_plc_session(src_addr)
|
||||
|
||||
@@ -201,7 +261,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
|
||||
end
|
||||
elseif r_chan == rtu_channel then
|
||||
elseif r_chan == config.RTU_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_rtu_session(src_addr)
|
||||
|
||||
@@ -265,7 +325,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
|
||||
end
|
||||
elseif r_chan == crd_channel then
|
||||
elseif r_chan == config.CRD_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_crd_session(src_addr)
|
||||
|
||||
@@ -299,7 +359,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { num_reactors, cooling_conf })
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
|
||||
else
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
@@ -332,7 +392,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
|
||||
end
|
||||
elseif r_chan == pkt_channel then
|
||||
elseif r_chan == config.PKT_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_pdg_session(src_addr)
|
||||
|
||||
|
||||
Reference in New Issue