#366 added idling to config and adjusted/fixed some behaviors
This commit is contained in:
@@ -23,7 +23,7 @@ local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local WASTE_MODE = types.WASTE_MODE
|
||||
local WASTE = types.WASTE_PRODUCT
|
||||
|
||||
local IO = rsio.IO
|
||||
local IO = rsio.IO
|
||||
|
||||
local DTV_RTU_S_DATA = qtypes.DTV_RTU_S_DATA
|
||||
|
||||
@@ -63,9 +63,9 @@ local facility = {}
|
||||
|
||||
-- create a new facility management object
|
||||
---@nodiscard
|
||||
---@param num_reactors integer number of reactor units
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
|
||||
function facility.new(num_reactors, cooling_conf)
|
||||
function facility.new(config, cooling_conf)
|
||||
local self = {
|
||||
units = {},
|
||||
status_text = { "START UP", "initializing..." },
|
||||
@@ -134,8 +134,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
}
|
||||
|
||||
-- create units
|
||||
for i = 1, num_reactors do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount))
|
||||
for i = 1, config.UnitCount do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.group_map, 0)
|
||||
end
|
||||
|
||||
@@ -499,8 +499,10 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
self.saturated = output ~= out_c
|
||||
|
||||
-- stop idling early if the output is zero, we are at or above the setpoint, and are not losing charge
|
||||
_set_idling(not ((out_c == 0) and (error <= 0) and (avg_outflow <= 0)))
|
||||
if not config.ExtChargeIdling then
|
||||
-- stop idling early if the output is zero, we are at or above the setpoint, and are not losing charge
|
||||
_set_idling(not ((out_c == 0) and (error <= 0) and (avg_outflow <= 0)))
|
||||
end
|
||||
|
||||
-- log.debug(util.sprintf("CHARGE[%f] { CHRG[%f] ERR[%f] INT[%f] => OUT[%f] OUT_C[%f] <= P[%f] I[%f] D[%f] }",
|
||||
-- runtime, avg_charge, error, integral, output, out_c, P, I, D))
|
||||
@@ -952,41 +954,41 @@ function facility.new(num_reactors, cooling_conf)
|
||||
function public.auto_stop() self.mode = PROCESS.INACTIVE end
|
||||
|
||||
-- set automatic control configuration and start the process
|
||||
---@param config coord_auto_config configuration
|
||||
---@param auto_cfg coord_auto_config configuration
|
||||
---@return table response ready state (successfully started) and current configuration (after updating)
|
||||
function public.auto_start(config)
|
||||
function public.auto_start(auto_cfg)
|
||||
local charge_scaler = 1000000 -- convert MFE to FE
|
||||
local gen_scaler = 1000 -- convert kFE to FE
|
||||
local ready = false
|
||||
|
||||
-- load up current limits
|
||||
local limits = {}
|
||||
for i = 1, num_reactors do
|
||||
for i = 1, config.UnitCount do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
limits[i] = u.get_control_inf().lim_br100 * 100
|
||||
end
|
||||
|
||||
-- only allow changes if not running
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if (type(config.mode) == "number") and (config.mode > PROCESS.INACTIVE) and (config.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = config.mode
|
||||
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = auto_cfg.mode
|
||||
end
|
||||
|
||||
if (type(config.burn_target) == "number") and config.burn_target >= 0.1 then
|
||||
self.burn_target = config.burn_target
|
||||
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
|
||||
self.burn_target = auto_cfg.burn_target
|
||||
end
|
||||
|
||||
if (type(config.charge_target) == "number") and config.charge_target >= 0 then
|
||||
self.charge_setpoint = config.charge_target * charge_scaler
|
||||
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
|
||||
self.charge_setpoint = auto_cfg.charge_target * charge_scaler
|
||||
end
|
||||
|
||||
if (type(config.gen_target) == "number") and config.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = config.gen_target * gen_scaler
|
||||
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = auto_cfg.gen_target * gen_scaler
|
||||
end
|
||||
|
||||
if (type(config.limits) == "table") and (#config.limits == num_reactors) then
|
||||
for i = 1, num_reactors do
|
||||
local limit = config.limits[i]
|
||||
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
|
||||
for i = 1, config.UnitCount do
|
||||
local limit = auto_cfg.limits[i]
|
||||
|
||||
if (type(limit) == "number") and (limit >= 0.1) then
|
||||
limits[i] = limit
|
||||
@@ -1026,7 +1028,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
---@param unit_id integer unit ID
|
||||
---@param group integer group ID or 0 for independent
|
||||
function public.set_group(unit_id, group)
|
||||
if (group >= 0 and group <= 4) and (unit_id > 0 and unit_id <= num_reactors) and self.mode == PROCESS.INACTIVE then
|
||||
if (group >= 0 and group <= 4) and (unit_id > 0 and unit_id <= config.UnitCount) and self.mode == PROCESS.INACTIVE then
|
||||
-- remove from old group if previously assigned
|
||||
local old_group = self.group_map[unit_id]
|
||||
if old_group ~= 0 then
|
||||
|
||||