#171 unit auto SCRAM and improvements to emergency coolant control
This commit is contained in:
@@ -82,7 +82,10 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- redstone control
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
valves = {}, ---@type unit_valves
|
||||
emcool_opened = false,
|
||||
-- auto control
|
||||
auto_engaged = false,
|
||||
auto_was_alarmed = false,
|
||||
ramp_target_br100 = 0,
|
||||
-- state tracking
|
||||
deltas = {},
|
||||
@@ -141,25 +144,25 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- radiation monitor alarm for this unit
|
||||
ContainmentRadiation = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ContainmentRadiation, tier = PRIO.CRITICAL },
|
||||
-- reactor offline after being online
|
||||
ReactorLost = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorLost, tier = PRIO.URGENT },
|
||||
ReactorLost = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorLost, tier = PRIO.TIMELY },
|
||||
-- damage >100%
|
||||
CriticalDamage = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.CriticalDamage, tier = PRIO.CRITICAL },
|
||||
-- reactor damage increasing
|
||||
ReactorDamage = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorDamage, tier = PRIO.EMERGENCY },
|
||||
-- reactor >1200K
|
||||
ReactorOverTemp = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorOverTemp, tier = PRIO.URGENT },
|
||||
-- reactor >1100K
|
||||
ReactorHighTemp = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.ReactorHighTemp, tier = PRIO.TIMELY },
|
||||
-- reactor >1150K
|
||||
ReactorHighTemp = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 1, id = ALARM.ReactorHighTemp, tier = PRIO.TIMELY },
|
||||
-- waste = 100%
|
||||
ReactorWasteLeak = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorWasteLeak, tier = PRIO.EMERGENCY },
|
||||
-- waste >85%
|
||||
ReactorHighWaste = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.ReactorHighWaste, tier = PRIO.TIMELY },
|
||||
ReactorHighWaste = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.ReactorHighWaste, tier = PRIO.URGENT },
|
||||
-- RPS trip occured
|
||||
RPSTransient = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 1, id = ALARM.RPSTransient, tier = PRIO.TIMELY },
|
||||
RPSTransient = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.RPSTransient, tier = PRIO.TIMELY },
|
||||
-- BoilRateMismatch, CoolantFeedMismatch, SteamFeedMismatch, MaxWaterReturnFeed
|
||||
RCSTransient = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 5, id = ALARM.RCSTransient, tier = PRIO.TIMELY },
|
||||
-- "It's just a routine turbin' trip!" -Bill Gibson, "The China Syndrome"
|
||||
TurbineTrip = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 1, id = ALARM.TurbineTrip, tier = PRIO.URGENT }
|
||||
TurbineTrip = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.TurbineTrip, tier = PRIO.URGENT }
|
||||
},
|
||||
---@class unit_db
|
||||
db = {
|
||||
@@ -488,12 +491,17 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- update alarm status
|
||||
logic.update_alarms(self)
|
||||
|
||||
-- if in auto mode, SCRAM on certain alarms
|
||||
logic.update_auto_safety(public, self)
|
||||
|
||||
-- update status text
|
||||
logic.update_status_text(self)
|
||||
|
||||
-- handle redstone I/O
|
||||
if #self.redstone > 0 then
|
||||
logic.handle_redstone(self)
|
||||
elseif not self.plc_cache.rps_trip then
|
||||
self.emcool_opened = false
|
||||
end
|
||||
end
|
||||
|
||||
@@ -502,7 +510,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- engage automatic control
|
||||
function public.a_engage()
|
||||
self.db.annunciator.AutoControl = true
|
||||
self.auto_engaged = true
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_lock(true)
|
||||
end
|
||||
@@ -510,7 +518,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- disengage automatic control
|
||||
function public.a_disengage()
|
||||
self.db.annunciator.AutoControl = false
|
||||
self.auto_engaged = false
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_lock(false)
|
||||
self.db.control.br100 = 0
|
||||
@@ -533,7 +541,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- set the automatic burn rate based on the last set burn rate in 100ths
|
||||
---@param ramp boolean true to ramp to rate, false to set right away
|
||||
function public.a_commit_br100(ramp)
|
||||
if self.db.annunciator.AutoControl then
|
||||
if self.auto_engaged then
|
||||
if self.plc_i ~= nil then
|
||||
self.plc_i.auto_set_burn(self.db.control.br100 / 100, ramp)
|
||||
|
||||
@@ -562,7 +570,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- queue a command to clear timeout/auto-scram if set
|
||||
function public.a_cond_rps_reset()
|
||||
if self.plc_s ~= nil and self.plc_i ~= nil then
|
||||
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then
|
||||
local rps = self.plc_i.get_rps()
|
||||
if rps.timeout or rps.automatic then
|
||||
self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it
|
||||
@@ -668,8 +676,8 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- check if a critical alarm is tripped
|
||||
function public.has_critical_alarm()
|
||||
for _, data in pairs(self.alarms) do
|
||||
if data.tier == PRIO.CRITICAL and (data.state == AISTATE.TRIPPED or data.state == AISTATE.ACKED) then
|
||||
for _, alarm in pairs(self.alarms) do
|
||||
if alarm.tier == PRIO.CRITICAL and (alarm.state == AISTATE.TRIPPED or alarm.state == AISTATE.ACKED) then
|
||||
return true
|
||||
end
|
||||
end
|
||||
|
||||
Reference in New Issue