#8 base class for RTU unit sessions, handle MODBUS error responses

This commit is contained in:
Mikayla Fischler
2022-05-17 17:16:04 -04:00
parent 31ede51c42
commit 9c034c366b
7 changed files with 349 additions and 304 deletions

View File

@@ -2,19 +2,21 @@ local comms = require("scada-common.comms")
local log = require("scada-common.log")
local types = require("scada-common.types")
local txnctrl = require("supervisor.session.rtu.txnctrl")
local unit_session = require("supervisor.session.rtu.unit_session")
local emachine = {}
local PROTOCOLS = comms.PROTOCOLS
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local MODBUS_FCODE = types.MODBUS_FCODE
local rtu_t = types.rtu_t
local TXN_TYPES = {
BUILD = 0,
STORAGE = 1
BUILD = 1,
STORAGE = 2
}
local TXN_TAGS = {
"emachine.build",
"emachine.storage"
}
local PERIODICS = {
@@ -36,12 +38,7 @@ emachine.new = function (session_id, advert, out_queue)
local log_tag = "session.rtu(" .. session_id .. ").emachine(" .. advert.index .. "): "
local self = {
uid = advert.index,
-- reactor = advert.reactor,
reactor = 0,
out_q = out_queue,
transaction_controller = txnctrl.new(),
connected = true,
session = unit_session.new(log_tag, advert, out_queue, TXN_TAGS),
has_build = false,
periodics = {
next_build_req = 0,
@@ -60,30 +57,20 @@ emachine.new = function (session_id, advert, out_queue)
}
}
---@class unit_session
local public = {}
local public = self.session.get()
-- PRIVATE FUNCTIONS --
local _send_request = function (txn_type, f_code, register_range)
local m_pkt = comms.modbus_packet()
local txn_id = self.transaction_controller.create(txn_type)
m_pkt.make(txn_id, self.uid, f_code, register_range)
self.out_q.push_packet(m_pkt)
end
-- query the build of the device
local _request_build = function ()
-- read input register 1 (start = 1, count = 1)
_send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 1 })
self.session.send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 1 })
end
-- query the state of the energy storage
local _request_storage = function ()
-- read input registers 2 through 4 (start = 2, count = 3)
_send_request(TXN_TYPES.STORAGE, MODBUS_FCODE.READ_INPUT_REGS, { 2, 3 })
self.session.send_request(TXN_TYPES.STORAGE, MODBUS_FCODE.READ_INPUT_REGS, { 2, 3 })
end
-- PUBLIC FUNCTIONS --
@@ -91,49 +78,32 @@ emachine.new = function (session_id, advert, out_queue)
-- handle a packet
---@param m_pkt modbus_frame
public.handle_packet = function (m_pkt)
local success = false
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
if m_pkt.unit_id == self.uid then
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
if txn_type == TXN_TYPES.BUILD then
-- build response
if m_pkt.length == 1 then
self.db.build.max_energy = m_pkt.data[1]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.build)")
end
elseif txn_type == TXN_TYPES.STORAGE then
-- storage response
if m_pkt.length == 3 then
self.db.storage.energy = m_pkt.data[1]
self.db.storage.energy_need = m_pkt.data[2]
self.db.storage.energy_fill = m_pkt.data[3]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.storage)")
end
elseif txn_type == nil then
log.error(log_tag .. "unknown transaction reply")
else
log.error(log_tag .. "unknown transaction type " .. txn_type)
end
local txn_type = self.session.try_resolve(m_pkt.txn_id)
if txn_type == false then
-- nothing to do
elseif txn_type == TXN_TYPES.BUILD then
-- build response
if m_pkt.length == 1 then
self.db.build.max_energy = m_pkt.data[1]
else
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.build)")
end
elseif txn_type == TXN_TYPES.STORAGE then
-- storage response
if m_pkt.length == 3 then
self.db.storage.energy = m_pkt.data[1]
self.db.storage.energy_need = m_pkt.data[2]
self.db.storage.energy_fill = m_pkt.data[3]
else
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.storage)")
end
elseif txn_type == nil then
log.error(log_tag .. "unknown transaction reply")
else
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
log.error(log_tag .. "unknown transaction type " .. txn_type)
end
return success
end
public.get_uid = function () return self.uid end
public.get_reactor = function () return self.reactor end
public.get_db = function () return self.db end
public.close = function () self.connected = false end
public.is_connected = function () return self.connected end
-- update this runner
---@param time_now integer milliseconds
public.update = function (time_now)
@@ -148,6 +118,9 @@ emachine.new = function (session_id, advert, out_queue)
end
end
-- get the unit session database
public.get_db = function () return self.db end
return public
end