#8 base class for RTU unit sessions, handle MODBUS error responses
This commit is contained in:
@@ -2,19 +2,21 @@ local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local types = require("scada-common.types")
|
||||
|
||||
local txnctrl = require("supervisor.session.rtu.txnctrl")
|
||||
local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local emachine = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
local rtu_t = types.rtu_t
|
||||
|
||||
local TXN_TYPES = {
|
||||
BUILD = 0,
|
||||
STORAGE = 1
|
||||
BUILD = 1,
|
||||
STORAGE = 2
|
||||
}
|
||||
|
||||
local TXN_TAGS = {
|
||||
"emachine.build",
|
||||
"emachine.storage"
|
||||
}
|
||||
|
||||
local PERIODICS = {
|
||||
@@ -36,12 +38,7 @@ emachine.new = function (session_id, advert, out_queue)
|
||||
local log_tag = "session.rtu(" .. session_id .. ").emachine(" .. advert.index .. "): "
|
||||
|
||||
local self = {
|
||||
uid = advert.index,
|
||||
-- reactor = advert.reactor,
|
||||
reactor = 0,
|
||||
out_q = out_queue,
|
||||
transaction_controller = txnctrl.new(),
|
||||
connected = true,
|
||||
session = unit_session.new(log_tag, advert, out_queue, TXN_TAGS),
|
||||
has_build = false,
|
||||
periodics = {
|
||||
next_build_req = 0,
|
||||
@@ -60,30 +57,20 @@ emachine.new = function (session_id, advert, out_queue)
|
||||
}
|
||||
}
|
||||
|
||||
---@class unit_session
|
||||
local public = {}
|
||||
local public = self.session.get()
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send_request = function (txn_type, f_code, register_range)
|
||||
local m_pkt = comms.modbus_packet()
|
||||
local txn_id = self.transaction_controller.create(txn_type)
|
||||
|
||||
m_pkt.make(txn_id, self.uid, f_code, register_range)
|
||||
|
||||
self.out_q.push_packet(m_pkt)
|
||||
end
|
||||
|
||||
-- query the build of the device
|
||||
local _request_build = function ()
|
||||
-- read input register 1 (start = 1, count = 1)
|
||||
_send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 1 })
|
||||
self.session.send_request(TXN_TYPES.BUILD, MODBUS_FCODE.READ_INPUT_REGS, { 1, 1 })
|
||||
end
|
||||
|
||||
-- query the state of the energy storage
|
||||
local _request_storage = function ()
|
||||
-- read input registers 2 through 4 (start = 2, count = 3)
|
||||
_send_request(TXN_TYPES.STORAGE, MODBUS_FCODE.READ_INPUT_REGS, { 2, 3 })
|
||||
self.session.send_request(TXN_TYPES.STORAGE, MODBUS_FCODE.READ_INPUT_REGS, { 2, 3 })
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
@@ -91,49 +78,32 @@ emachine.new = function (session_id, advert, out_queue)
|
||||
-- handle a packet
|
||||
---@param m_pkt modbus_frame
|
||||
public.handle_packet = function (m_pkt)
|
||||
local success = false
|
||||
|
||||
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
if m_pkt.unit_id == self.uid then
|
||||
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
|
||||
if txn_type == TXN_TYPES.BUILD then
|
||||
-- build response
|
||||
if m_pkt.length == 1 then
|
||||
self.db.build.max_energy = m_pkt.data[1]
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.build)")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.STORAGE then
|
||||
-- storage response
|
||||
if m_pkt.length == 3 then
|
||||
self.db.storage.energy = m_pkt.data[1]
|
||||
self.db.storage.energy_need = m_pkt.data[2]
|
||||
self.db.storage.energy_fill = m_pkt.data[3]
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.storage)")
|
||||
end
|
||||
elseif txn_type == nil then
|
||||
log.error(log_tag .. "unknown transaction reply")
|
||||
else
|
||||
log.error(log_tag .. "unknown transaction type " .. txn_type)
|
||||
end
|
||||
local txn_type = self.session.try_resolve(m_pkt.txn_id)
|
||||
if txn_type == false then
|
||||
-- nothing to do
|
||||
elseif txn_type == TXN_TYPES.BUILD then
|
||||
-- build response
|
||||
if m_pkt.length == 1 then
|
||||
self.db.build.max_energy = m_pkt.data[1]
|
||||
else
|
||||
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.build)")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.STORAGE then
|
||||
-- storage response
|
||||
if m_pkt.length == 3 then
|
||||
self.db.storage.energy = m_pkt.data[1]
|
||||
self.db.storage.energy_need = m_pkt.data[2]
|
||||
self.db.storage.energy_fill = m_pkt.data[3]
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (emachine.storage)")
|
||||
end
|
||||
elseif txn_type == nil then
|
||||
log.error(log_tag .. "unknown transaction reply")
|
||||
else
|
||||
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
|
||||
log.error(log_tag .. "unknown transaction type " .. txn_type)
|
||||
end
|
||||
|
||||
return success
|
||||
end
|
||||
|
||||
public.get_uid = function () return self.uid end
|
||||
public.get_reactor = function () return self.reactor end
|
||||
public.get_db = function () return self.db end
|
||||
|
||||
public.close = function () self.connected = false end
|
||||
public.is_connected = function () return self.connected end
|
||||
|
||||
-- update this runner
|
||||
---@param time_now integer milliseconds
|
||||
public.update = function (time_now)
|
||||
@@ -148,6 +118,9 @@ emachine.new = function (session_id, advert, out_queue)
|
||||
end
|
||||
end
|
||||
|
||||
-- get the unit session database
|
||||
public.get_db = function () return self.db end
|
||||
|
||||
return public
|
||||
end
|
||||
|
||||
|
||||
Reference in New Issue