#8 base class for RTU unit sessions, handle MODBUS error responses
This commit is contained in:
@@ -5,11 +5,10 @@ local rsio = require("scada-common.rsio")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local txnctrl = require("supervisor.session.rtu.txnctrl")
|
||||
local unit_session = require("supervisor.session.rtu.unit_session")
|
||||
|
||||
local redstone = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
|
||||
@@ -18,8 +17,6 @@ local IO_LVL = rsio.IO_LVL
|
||||
local IO_DIR = rsio.IO_DIR
|
||||
local IO_MODE = rsio.IO_MODE
|
||||
|
||||
local rtu_t = types.rtu_t
|
||||
|
||||
local RS_RTU_S_CMDS = {
|
||||
}
|
||||
|
||||
@@ -31,10 +28,17 @@ redstone.RS_RTU_S_CMDS = RS_RTU_S_CMDS
|
||||
redstone.RS_RTU_S_DATA = RS_RTU_S_DATA
|
||||
|
||||
local TXN_TYPES = {
|
||||
DI_READ = 0,
|
||||
COIL_WRITE = 1,
|
||||
INPUT_REG_READ = 2,
|
||||
HOLD_REG_WRITE = 3
|
||||
DI_READ = 1,
|
||||
COIL_WRITE = 2,
|
||||
INPUT_REG_READ = 3,
|
||||
HOLD_REG_WRITE = 4
|
||||
}
|
||||
|
||||
local TXN_TAGS = {
|
||||
"redstone.di_read",
|
||||
"redstone.coil_write",
|
||||
"redstone.input_reg_write",
|
||||
"redstone.hold_reg_write"
|
||||
}
|
||||
|
||||
local PERIODICS = {
|
||||
@@ -55,12 +59,7 @@ redstone.new = function (session_id, advert, out_queue)
|
||||
local log_tag = "session.rtu(" .. session_id .. ").redstone(" .. advert.index .. "): "
|
||||
|
||||
local self = {
|
||||
uid = advert.index,
|
||||
reactor = advert.reactor,
|
||||
in_q = mqueue.new(),
|
||||
out_q = out_queue,
|
||||
transaction_controller = txnctrl.new(),
|
||||
connected = true,
|
||||
session = unit_session.new(log_tag, advert, out_queue, TXN_TAGS),
|
||||
has_di = false,
|
||||
has_ai = false,
|
||||
periodics = {
|
||||
@@ -76,8 +75,7 @@ redstone.new = function (session_id, advert, out_queue)
|
||||
db = {}
|
||||
}
|
||||
|
||||
---@class unit_session
|
||||
local public = {}
|
||||
local public = self.session.get()
|
||||
|
||||
-- INITIALIZE --
|
||||
|
||||
@@ -110,36 +108,26 @@ redstone.new = function (session_id, advert, out_queue)
|
||||
self.db[channel] = IO_LVL.LOW
|
||||
end
|
||||
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
local _send_request = function (txn_type, f_code, parameters)
|
||||
local m_pkt = comms.modbus_packet()
|
||||
local txn_id = self.transaction_controller.create(txn_type)
|
||||
|
||||
m_pkt.make(txn_id, self.uid, f_code, parameters)
|
||||
|
||||
self.out_q.push_packet(m_pkt)
|
||||
end
|
||||
|
||||
-- query discrete inputs
|
||||
local _request_discrete_inputs = function ()
|
||||
_send_request(TXN_TYPES.DI_READ, MODBUS_FCODE.READ_DISCRETE_INPUTS, { 1, #self.io_list.digital_in })
|
||||
self.session.send_request(TXN_TYPES.DI_READ, MODBUS_FCODE.READ_DISCRETE_INPUTS, { 1, #self.io_list.digital_in })
|
||||
end
|
||||
|
||||
-- query input registers
|
||||
local _request_input_registers = function ()
|
||||
_send_request(TXN_TYPES.INPUT_REG_READ, MODBUS_FCODE.READ_INPUT_REGS, { 1, #self.io_list.analog_in })
|
||||
self.session.send_request(TXN_TYPES.INPUT_REG_READ, MODBUS_FCODE.READ_INPUT_REGS, { 1, #self.io_list.analog_in })
|
||||
end
|
||||
|
||||
-- write coil output
|
||||
local _write_coil = function (coil, value)
|
||||
_send_request(TXN_TYPES.COIL_WRITE, MODBUS_FCODE.WRITE_MUL_COILS, { coil, value })
|
||||
self.session.send_request(TXN_TYPES.COIL_WRITE, MODBUS_FCODE.WRITE_MUL_COILS, { coil, value })
|
||||
end
|
||||
|
||||
-- write holding register output
|
||||
local _write_holding_register = function (reg, value)
|
||||
_send_request(TXN_TYPES.HOLD_REG_WRITE, MODBUS_FCODE.WRITE_MUL_HOLD_REGS, { reg, value })
|
||||
self.session.send_request(TXN_TYPES.HOLD_REG_WRITE, MODBUS_FCODE.WRITE_MUL_HOLD_REGS, { reg, value })
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
@@ -147,55 +135,40 @@ redstone.new = function (session_id, advert, out_queue)
|
||||
-- handle a packet
|
||||
---@param m_pkt modbus_frame
|
||||
public.handle_packet = function (m_pkt)
|
||||
local success = false
|
||||
|
||||
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
if m_pkt.unit_id == self.uid then
|
||||
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
|
||||
if txn_type == TXN_TYPES.DI_READ then
|
||||
-- discrete input read response
|
||||
if m_pkt.length == #self.io_list.digital_in then
|
||||
for i = 1, m_pkt.length do
|
||||
local channel = self.io_list.digital_in[i]
|
||||
local value = m_pkt.data[i]
|
||||
self.db[channel] = value
|
||||
end
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (redstone.discrete_input_read)")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.INPUT_REG_READ then
|
||||
-- input register read response
|
||||
if m_pkt.length == #self.io_list.analog_in then
|
||||
for i = 1, m_pkt.length do
|
||||
local channel = self.io_list.analog_in[i]
|
||||
local value = m_pkt.data[i]
|
||||
self.db[channel] = value
|
||||
end
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (redstone.input_reg_read)")
|
||||
end
|
||||
elseif txn_type == nil then
|
||||
log.error(log_tag .. "unknown transaction reply")
|
||||
else
|
||||
log.error(log_tag .. "unknown transaction type " .. txn_type)
|
||||
local txn_type = self.session.try_resolve(m_pkt.txn_id)
|
||||
if txn_type == false then
|
||||
-- nothing to do
|
||||
elseif txn_type == TXN_TYPES.DI_READ then
|
||||
-- discrete input read response
|
||||
if m_pkt.length == #self.io_list.digital_in then
|
||||
for i = 1, m_pkt.length do
|
||||
local channel = self.io_list.digital_in[i]
|
||||
local value = m_pkt.data[i]
|
||||
self.db[channel] = value
|
||||
end
|
||||
else
|
||||
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (redstone.di_read)")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.INPUT_REG_READ then
|
||||
-- input register read response
|
||||
if m_pkt.length == #self.io_list.analog_in then
|
||||
for i = 1, m_pkt.length do
|
||||
local channel = self.io_list.analog_in[i]
|
||||
local value = m_pkt.data[i]
|
||||
self.db[channel] = value
|
||||
end
|
||||
else
|
||||
log.debug(log_tag .. "MODBUS transaction reply length mismatch (redstone.input_reg_read)")
|
||||
end
|
||||
elseif txn_type == TXN_TYPES.COIL_WRITE or txn_type == TXN_TYPES.HOLD_REG_WRITE then
|
||||
-- successful acknowledgement
|
||||
elseif txn_type == nil then
|
||||
log.error(log_tag .. "unknown transaction reply")
|
||||
else
|
||||
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
|
||||
log.error(log_tag .. "unknown transaction type " .. txn_type)
|
||||
end
|
||||
|
||||
return success
|
||||
end
|
||||
|
||||
public.get_uid = function () return self.uid end
|
||||
public.get_reactor = function () return self.reactor end
|
||||
public.get_db = function () return self.db end
|
||||
|
||||
public.close = function () self.connected = false end
|
||||
public.is_connected = function () return self.connected end
|
||||
|
||||
-- update this runner
|
||||
---@param time_now integer milliseconds
|
||||
public.update = function (time_now)
|
||||
@@ -270,6 +243,9 @@ redstone.new = function (session_id, advert, out_queue)
|
||||
end
|
||||
end
|
||||
|
||||
-- get the unit session database
|
||||
public.get_db = function () return self.db end
|
||||
|
||||
return public, self.in_q
|
||||
end
|
||||
|
||||
|
||||
Reference in New Issue