#8 base class for RTU unit sessions, handle MODBUS error responses
This commit is contained in:
132
supervisor/session/rtu/unit_session.lua
Normal file
132
supervisor/session/rtu/unit_session.lua
Normal file
@@ -0,0 +1,132 @@
|
||||
local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local types = require("scada-common.types")
|
||||
|
||||
local txnctrl = require("supervisor.session.rtu.txnctrl")
|
||||
|
||||
local unit_session = {}
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local MODBUS_FCODE = types.MODBUS_FCODE
|
||||
local MODBUS_EXCODE = types.MODBUS_EXCODE
|
||||
|
||||
-- create a new unit session runner
|
||||
---@param log_tag string
|
||||
---@param advert rtu_advertisement
|
||||
---@param out_queue mqueue
|
||||
---@param txn_tags table
|
||||
unit_session.new = function (log_tag, advert, out_queue, txn_tags)
|
||||
local self = {
|
||||
log_tag = log_tag,
|
||||
txn_tags = txn_tags,
|
||||
uid = advert.index,
|
||||
reactor = advert.reactor,
|
||||
out_q = out_queue,
|
||||
transaction_controller = txnctrl.new(),
|
||||
connected = true,
|
||||
device_fail = false
|
||||
}
|
||||
|
||||
---@class _unit_session
|
||||
local protected = {}
|
||||
|
||||
---@class unit_session
|
||||
local public = {}
|
||||
|
||||
-- PROTECTED FUNCTIONS --
|
||||
|
||||
-- send a MODBUS message, creating a transaction in the process
|
||||
---@param txn_type integer transaction type
|
||||
---@param f_code MODBUS_FCODE function code
|
||||
---@param register_param table register range or register and values
|
||||
protected.send_request = function (txn_type, f_code, register_param)
|
||||
local m_pkt = comms.modbus_packet()
|
||||
local txn_id = self.transaction_controller.create(txn_type)
|
||||
|
||||
m_pkt.make(txn_id, self.uid, f_code, register_param)
|
||||
|
||||
self.out_q.push_packet(m_pkt)
|
||||
end
|
||||
|
||||
-- try to resolve a MODBUS transaction
|
||||
---@param m_pkt modbus_frame MODBUS packet
|
||||
---@return integer|false txn_type transaction type or false on error/busy
|
||||
protected.try_resolve = function (m_pkt)
|
||||
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
|
||||
if m_pkt.unit_id == self.uid then
|
||||
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
|
||||
local txn_tag = " (" .. self.txn_tags[txn_type] .. ")"
|
||||
|
||||
if bit.band(m_pkt.func_code, MODBUS_FCODE.ERROR_FLAG) ~= 0 then
|
||||
-- transaction incomplete or failed
|
||||
local ex = m_pkt.data[1]
|
||||
if ex == MODBUS_EXCODE.ILLEGAL_FUNCTION then
|
||||
log.error(log_tag .. "MODBUS: illegal function" .. txn_tag)
|
||||
elseif ex == MODBUS_EXCODE.ILLEGAL_DATA_ADDR then
|
||||
log.error(log_tag .. "MODBUS: illegal data address" .. txn_tag)
|
||||
elseif ex == MODBUS_EXCODE.SERVER_DEVICE_FAIL then
|
||||
if self.device_fail then
|
||||
log.debug(log_tag .. "MODBUS: repeated device failure" .. txn_tag)
|
||||
else
|
||||
self.device_fail = true
|
||||
log.warning(log_tag .. "MODBUS: device failure" .. txn_tag)
|
||||
end
|
||||
elseif ex == MODBUS_EXCODE.ACKNOWLEDGE then
|
||||
-- will have to wait on reply, renew the transaction
|
||||
self.transaction_controller.renew(m_pkt.txn_id, txn_type)
|
||||
elseif ex == MODBUS_EXCODE.SERVER_DEVICE_BUSY then
|
||||
-- will have to wait on reply, renew the transaction
|
||||
self.transaction_controller.renew(m_pkt.txn_id, txn_type)
|
||||
log.debug(log_tag .. "MODBUS: device busy" .. txn_tag)
|
||||
elseif ex == MODBUS_EXCODE.NEG_ACKNOWLEDGE then
|
||||
-- general failure
|
||||
log.error(log_tag .. "MODBUS: negative acknowledge (bad request)" .. txn_tag)
|
||||
elseif ex == MODBUS_EXCODE.GATEWAY_PATH_UNAVAILABLE then
|
||||
-- RTU gateway has no known unit with the given ID
|
||||
log.error(log_tag .. "MODBUS: gateway path unavailable (unknown unit)" .. txn_tag)
|
||||
elseif ex ~= nil then
|
||||
-- unsupported exception code
|
||||
log.debug(log_tag .. "MODBUS: unsupported error " .. ex .. txn_tag)
|
||||
else
|
||||
-- nil exception code
|
||||
log.debug(log_tag .. "MODBUS: nil exception code" .. txn_tag)
|
||||
end
|
||||
else
|
||||
-- clear device fail flag
|
||||
self.device_fail = false
|
||||
|
||||
-- no error, return the transaction type
|
||||
return txn_type
|
||||
end
|
||||
else
|
||||
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
|
||||
end
|
||||
else
|
||||
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
|
||||
end
|
||||
|
||||
-- error or transaction in progress, return false
|
||||
return false
|
||||
end
|
||||
|
||||
-- get the public interface
|
||||
protected.get = function () return public end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- get the unit ID
|
||||
public.get_uid = function () return self.uid end
|
||||
-- get the reactor ID
|
||||
public.get_reactor = function () return self.reactor end
|
||||
|
||||
-- close this unit
|
||||
public.close = function () self.connected = false end
|
||||
-- check if this unit is connected
|
||||
public.is_connected = function () return self.connected end
|
||||
-- check if this unit is faulted
|
||||
public.is_faulted = function () return self.device_fail end
|
||||
|
||||
return protected
|
||||
end
|
||||
|
||||
return unit_session
|
||||
Reference in New Issue