#367 reject and record bad or duplicate RTU IDs
This commit is contained in:
@@ -65,7 +65,8 @@ local facility = {}
|
||||
---@nodiscard
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
|
||||
function facility.new(config, cooling_conf)
|
||||
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
|
||||
function facility.new(config, cooling_conf, check_rtu_id)
|
||||
local self = {
|
||||
units = {},
|
||||
status_text = { "START UP", "initializing..." },
|
||||
@@ -144,7 +145,7 @@ function facility.new(config, cooling_conf)
|
||||
|
||||
-- create units
|
||||
for i = 1, config.UnitCount do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, check_rtu_id, config.ExtChargeIdling))
|
||||
table.insert(self.group_map, 0)
|
||||
end
|
||||
|
||||
@@ -257,20 +258,30 @@ function facility.new(config, cooling_conf)
|
||||
---@param imatrix unit_session
|
||||
---@return boolean linked induction matrix accepted (max 1)
|
||||
function public.add_imatrix(imatrix)
|
||||
if #self.induction == 0 then
|
||||
local fail_code, fail_str = check_rtu_id(imatrix, self.induction, 1)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.induction, imatrix)
|
||||
return true
|
||||
else return false end
|
||||
else
|
||||
log.warning(util.c("FAC: rejected induction matrix linking due to failure code ", fail_code, " (", fail_str, ")"))
|
||||
end
|
||||
|
||||
return fail_code == 0
|
||||
end
|
||||
|
||||
-- link an SPS RTU session
|
||||
---@param sps unit_session
|
||||
---@return boolean linked SPS accepted (max 1)
|
||||
function public.add_sps(sps)
|
||||
if #self.sps == 0 then
|
||||
local fail_code, fail_str = check_rtu_id(sps, self.sps, 1)
|
||||
|
||||
if fail_code == 0 then
|
||||
table.insert(self.sps, sps)
|
||||
return true
|
||||
else return false end
|
||||
else
|
||||
log.warning(util.c("FAC: rejected SPS linking due to failure code ", fail_code, " (", fail_str, ")"))
|
||||
end
|
||||
|
||||
return fail_code == 0
|
||||
end
|
||||
|
||||
-- link a dynamic tank RTU session
|
||||
@@ -293,7 +304,7 @@ function facility.new(config, cooling_conf)
|
||||
|
||||
-- update (iterate) the facility management
|
||||
function public.update()
|
||||
-- unlink RTU unit sessions if they are closed
|
||||
-- unlink RTU sessions if they are closed
|
||||
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
|
||||
|
||||
-- check if test routines are allowed right now
|
||||
|
||||
Reference in New Issue