#367 reject and record bad or duplicate RTU IDs

This commit is contained in:
Mikayla
2024-08-16 18:08:53 +00:00
parent bee96ed12e
commit ab97f8935d
4 changed files with 113 additions and 35 deletions

View File

@@ -63,11 +63,14 @@ local unit = {}
---@param reactor_id integer reactor unit number
---@param num_boilers integer number of boilers expected
---@param num_turbines integer number of turbines expected
---@param check_rtu_id function ID checking function for RTUs attempting to be linked
---@param ext_idle boolean extended idling mode
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function unit.new(reactor_id, num_boilers, num_turbines, check_rtu_id, ext_idle)
-- time (ms) to idle for auto idling
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
local log_tag = "UNIT " .. reactor_id .. ": "
---@class _unit_self
local self = {
r_id = reactor_id,
@@ -441,22 +444,28 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
---@param turbine unit_session
---@return boolean linked turbine accepted to associated device slot
function public.add_turbine(turbine)
if #self.turbines < num_turbines and turbine.get_device_idx() <= num_turbines then
local fail_code, fail_str = check_rtu_id(turbine, self.turbines, num_turbines)
if fail_code == 0 then
table.insert(self.turbines, turbine)
-- reset deltas
_reset_dt(DT_KEYS.TurbineSteam .. turbine.get_device_idx())
_reset_dt(DT_KEYS.TurbinePower .. turbine.get_device_idx())
else
log.warning(util.c(log_tag, "rejected turbine linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return true
else return false end
return fail_code == 0
end
-- link a boiler RTU session
---@param boiler unit_session
---@return boolean linked boiler accepted to associated device slot
function public.add_boiler(boiler)
if #self.boilers < num_boilers and boiler.get_device_idx() <= num_boilers then
local fail_code, fail_str = check_rtu_id(boiler, self.boilers, num_boilers)
if fail_code == 0 then
table.insert(self.boilers, boiler)
-- reset deltas
@@ -464,19 +473,26 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
_reset_dt(DT_KEYS.BoilerSteam .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerCCool .. boiler.get_device_idx())
_reset_dt(DT_KEYS.BoilerHCool .. boiler.get_device_idx())
else
log.warning(util.c(log_tag, "rejected boiler linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return true
else return false end
return fail_code == 0
end
-- link a dynamic tank RTU session
---@param dynamic_tank unit_session
---@return boolean linked dynamic tank accepted (max 1)
function public.add_tank(dynamic_tank)
if #self.tanks == 0 then
local fail_code, fail_str = check_rtu_id(dynamic_tank, self.tanks, 1)
if fail_code == 0 then
table.insert(self.tanks, dynamic_tank)
return true
else return false end
else
log.warning(util.c(log_tag, "rejected dynamic tank linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end
-- link a solar neutron activator RTU session
@@ -487,10 +503,15 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
---@param envd unit_session
---@return boolean linked environment detector accepted (max 1)
function public.add_envd(envd)
if #self.envd == 0 then
local fail_code, fail_str = check_rtu_id(envd, self.envd, 99)
if fail_code == 0 then
table.insert(self.envd, envd)
return true
else return false end
else
log.warning(util.c(log_tag, "rejected environment detector linking due to failure code ", fail_code, " (", fail_str, ")"))
end
return fail_code == 0
end
-- purge devices associated with the given RTU session ID
@@ -512,7 +533,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
self.db.control.br100 = 0
end
-- unlink RTU unit sessions if they are closed
-- unlink RTU sessions if they are closed
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- update degraded state for auto control
@@ -547,7 +568,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
-- stop idling when completed
if self.auto_idling and (((util.time_ms() - self.auto_idle_start) > IDLE_TIME) or not self.auto_idle) then
log.info(util.c("UNIT ", self.r_id, ": completed idling period"))
log.info(util.c(log_tag, "completed idling period"))
self.auto_idling = false
self.plc_i.auto_set_burn(0, false)
end
@@ -584,7 +605,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_engage()
self.auto_engaged = true
if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": engaged auto control"))
log.debug(util.c(log_tag, "engaged auto control"))
self.plc_i.auto_lock(true)
end
end
@@ -593,7 +614,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_disengage()
self.auto_engaged = false
if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": disengaged auto control"))
log.debug(util.c(log_tag, "disengaged auto control"))
self.plc_i.auto_lock(false)
self.db.control.br100 = 0
end
@@ -610,7 +631,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
end
if idle ~= self.auto_idle then
log.debug(util.c("UNIT ", self.r_id, ": idling mode changed to ", idle))
log.debug(util.c(log_tag, "idling mode changed to ", idle))
end
self.auto_idle = idle
@@ -623,7 +644,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_get_effective_limit()
local ctrl = self.db.control
if (not ctrl.ready) or ctrl.degraded or self.plc_cache.rps_trip then
-- log.debug(util.c("UNIT ", self.r_id, ": effective limit is zero! ready[", ctrl.ready, "] degraded[", ctrl.degraded, "] rps_trip[", self.plc_cache.rps_trip, "]"))
-- log.debug(util.c(log_tag, "effective limit is zero! ready[", ctrl.ready, "] degraded[", ctrl.degraded, "] rps_trip[", self.plc_cache.rps_trip, "]"))
ctrl.br100 = 0
return 0
else return ctrl.lim_br100 end
@@ -634,7 +655,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
function public.auto_commit_br100(ramp)
if self.auto_engaged then
if self.plc_i ~= nil then
log.debug(util.c("UNIT ", self.r_id, ": commit br100 of ", self.db.control.br100, " with ramp set to ", ramp))
log.debug(util.c(log_tag, "commit br100 of ", self.db.control.br100, " with ramp set to ", ramp))
local rate = self.db.control.br100 / 100
@@ -643,16 +664,16 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
if self.auto_idle_start == 0 then
self.auto_idling = true
self.auto_idle_start = util.time_ms()
log.info(util.c("UNIT ", self.r_id, ": started idling at ", IDLE_RATE, " mB/t"))
log.info(util.c(log_tag, "started idling at ", IDLE_RATE, " mB/t"))
rate = IDLE_RATE
elseif (util.time_ms() - self.auto_idle_start) > IDLE_TIME then
if self.auto_idling then
self.auto_idling = false
log.info(util.c("UNIT ", self.r_id, ": completed idling period"))
log.info(util.c(log_tag, "completed idling period"))
end
else
log.debug(util.c("UNIT ", self.r_id, ": continuing idle at ", IDLE_RATE, " mB/t"))
log.debug(util.c(log_tag, "continuing idle at ", IDLE_RATE, " mB/t"))
rate = IDLE_RATE
end