#106 reactor formed support and remounting

This commit is contained in:
Mikayla Fischler
2022-10-25 13:29:57 -04:00
parent a02fb6f691
commit b2be3ef5fc
9 changed files with 383 additions and 197 deletions

View File

@@ -38,7 +38,9 @@ local MAX_HEATED_COLLANT_FILL = 0.95
--- identifies dangerous states and SCRAMs reactor if warranted
---
--- autonomous from main SCADA supervisor/coordinator control
function plc.rps_init(reactor)
---@param reactor table
---@param is_formed boolean
function plc.rps_init(reactor, is_formed)
local state_keys = {
dmg_crit = 1,
high_temp = 2,
@@ -48,13 +50,15 @@ function plc.rps_init(reactor)
no_fuel = 6,
fault = 7,
timeout = 8,
manual = 9
manual = 9,
sys_fail = 10
}
local self = {
reactor = reactor,
state = { false, false, false, false, false, false, false, false, false },
state = { false, false, false, false, false, false, false, false, false, false },
reactor_enabled = false,
formed = is_formed,
tripped = false,
trip_cause = "" ---@type rps_trip_cause
}
@@ -76,14 +80,25 @@ function plc.rps_init(reactor)
self.state[state_keys.fault] = false
end
-- check if the reactor is formed
local function _is_formed()
local is_formed = self.reactor.isFormed()
if is_formed == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
elseif not self.state[state_keys.sys_fail] then
self.formed = is_formed
self.state[state_keys.sys_fail] = not is_formed
end
end
-- check for critical damage
local function _damage_critical()
local damage_percent = self.reactor.getDamagePercent()
if damage_percent == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.dmg_crit] = false
else
elseif not self.state[state_keys.dmg_crit] then
self.state[state_keys.dmg_crit] = damage_percent >= MAX_DAMAGE_PERCENT
end
end
@@ -95,8 +110,7 @@ function plc.rps_init(reactor)
if temp == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.high_temp] = false
else
elseif not self.state[state_keys.high_temp] then
self.state[state_keys.high_temp] = temp >= MAX_DAMAGE_TEMPERATURE
end
end
@@ -107,8 +121,7 @@ function plc.rps_init(reactor)
if coolant_filled == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.no_coolant] = false
else
elseif not self.state[state_keys.no_coolant] then
self.state[state_keys.no_coolant] = coolant_filled < MIN_COOLANT_FILL
end
end
@@ -119,8 +132,7 @@ function plc.rps_init(reactor)
if w_filled == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.ex_waste] = false
else
elseif not self.state[state_keys.ex_waste] then
self.state[state_keys.ex_waste] = w_filled > MAX_WASTE_FILL
end
end
@@ -131,8 +143,7 @@ function plc.rps_init(reactor)
if hc_filled == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.ex_hcoolant] = false
else
elseif not self.state[state_keys.ex_hcoolant] then
self.state[state_keys.ex_hcoolant] = hc_filled > MAX_HEATED_COLLANT_FILL
end
end
@@ -143,8 +154,7 @@ function plc.rps_init(reactor)
if fuel == ppm.ACCESS_FAULT then
-- lost the peripheral or terminated, handled later
_set_fault()
self.state[state_keys.no_fuel] = false
else
elseif not self.state[state_keys.no_fuel] then
self.state[state_keys.no_fuel] = fuel == 0
end
end
@@ -169,7 +179,13 @@ function plc.rps_init(reactor)
-- manually SCRAM the reactor
function public.trip_manual()
self.state[state_keys.manual] = true
self.state[state_keys.manual] = true
end
-- trip for unformed reactor
function public.trip_sys_fail()
self.state[state_keys.fault] = true
self.state[state_keys.sys_fail] = true
end
-- SCRAM the reactor now
@@ -216,6 +232,7 @@ function plc.rps_init(reactor)
-- update state
parallel.waitForAll(
_is_formed,
_damage_critical,
_high_temp,
_no_coolant,
@@ -227,6 +244,9 @@ function plc.rps_init(reactor)
-- check system states in order of severity
if self.tripped then
status = self.trip_cause
elseif self.state[state_keys.sys_fail] then
log.warning("RPS: system failure, reactor not formed")
status = rps_status_t.sys_fail
elseif self.state[state_keys.dmg_crit] then
log.warning("RPS: damage critical")
status = rps_status_t.dmg_crit
@@ -273,9 +293,11 @@ function plc.rps_init(reactor)
function public.status() return self.state end
function public.is_tripped() return self.tripped end
function public.is_active() return self.reactor_enabled end
function public.is_formed() return self.formed end
-- reset the RPS
function public.reset()
---@param quiet? boolean true to suppress the info log message
function public.reset(quiet)
self.tripped = false
self.trip_cause = rps_status_t.ok
@@ -283,7 +305,7 @@ function plc.rps_init(reactor)
self.state[i] = false
end
log.info("RPS: reset")
if not quiet then log.info("RPS: reset") end
end
return public
@@ -473,20 +495,19 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
local mek_data = { false, 0, 0, 0, min_pos, max_pos, 0, 0, 0, 0, 0, 0, 0, 0 }
local tasks = {
function () mek_data[1] = self.reactor.isFormed() end,
function () mek_data[2] = self.reactor.getLength() end,
function () mek_data[3] = self.reactor.getWidth() end,
function () mek_data[4] = self.reactor.getHeight() end,
function () mek_data[5] = self.reactor.getMinPos() end,
function () mek_data[6] = self.reactor.getMaxPos() end,
function () mek_data[7] = self.reactor.getHeatCapacity() end,
function () mek_data[8] = self.reactor.getFuelAssemblies() end,
function () mek_data[9] = self.reactor.getFuelSurfaceArea() end,
function () mek_data[10] = self.reactor.getFuelCapacity() end,
function () mek_data[11] = self.reactor.getWasteCapacity() end,
function () mek_data[12] = self.reactor.getCoolantCapacity() end,
function () mek_data[13] = self.reactor.getHeatedCoolantCapacity() end,
function () mek_data[14] = self.reactor.getMaxBurnRate() end
function () mek_data[1] = self.reactor.getLength() end,
function () mek_data[2] = self.reactor.getWidth() end,
function () mek_data[3] = self.reactor.getHeight() end,
function () mek_data[4] = self.reactor.getMinPos() end,
function () mek_data[5] = self.reactor.getMaxPos() end,
function () mek_data[6] = self.reactor.getHeatCapacity() end,
function () mek_data[7] = self.reactor.getFuelAssemblies() end,
function () mek_data[8] = self.reactor.getFuelSurfaceArea() end,
function () mek_data[9] = self.reactor.getFuelCapacity() end,
function () mek_data[10] = self.reactor.getWasteCapacity() end,
function () mek_data[11] = self.reactor.getCoolantCapacity() end,
function () mek_data[12] = self.reactor.getHeatedCoolantCapacity() end,
function () mek_data[13] = self.reactor.getMaxBurnRate() end
}
parallel.waitForAll(table.unpack(tasks))
@@ -536,29 +557,35 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
end
-- send live status information
---@param degraded boolean
function public.send_status(degraded)
---@param no_reactor boolean PLC lost reactor connection
---@param formed boolean reactor formed
function public.send_status(no_reactor, formed)
if self.linked then
local mek_data = nil
local mek_data = nil ---@type table
local heating_rate = nil ---@type number
if _update_status_cache() then
mek_data = self.status_cache
if (not no_reactor) and formed then
if _update_status_cache() then
mek_data = self.status_cache
log.debug("sent updated status")
else
log.debug("sent cached status")
end
heating_rate = self.reactor.getHeatingRate()
end
local sys_status = {
util.time(), -- timestamp
(not self.scrammed), -- requested control state
rps.is_tripped(), -- rps_tripped
degraded, -- degraded
self.reactor.getHeatingRate(), -- heating rate
no_reactor, -- no reactor peripheral connected
formed, -- reactor formed
heating_rate, -- heating rate
mek_data -- mekanism status data
}
if not self.reactor.__p_is_faulted() then
_send(RPLC_TYPES.STATUS, sys_status)
else
log.error("failed to send status: PPM fault")
end
_send(RPLC_TYPES.STATUS, sys_status)
end
end
@@ -570,7 +597,7 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
end
-- send reactor protection system alarm
---@param cause rps_status_t
---@param cause rps_status_t reactor protection system status
function public.send_rps_alarm(cause)
if self.linked then
local rps_alarm = {
@@ -618,9 +645,9 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
end
-- handle an RPLC packet
---@param packet rplc_frame|mgmt_frame
---@param plc_state plc_state
---@param setpoints setpoints
---@param packet rplc_frame|mgmt_frame packet frame
---@param plc_state plc_state PLC state
---@param setpoints setpoints setpoint control table
function public.handle_packet(packet, plc_state, setpoints)
if packet ~= nil and packet.scada_frame.local_port() == self.l_port then
-- check sequence number
@@ -651,7 +678,7 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
if link_ack == RPLC_LINKING.ALLOW then
self.status_cache = nil
_send_struct()
public.send_status(plc_state.degraded)
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("re-sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then
println_ts("received unsolicited link denial, unlinking")
@@ -671,7 +698,7 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
elseif packet.type == RPLC_TYPES.STATUS then
-- request of full status, clear cache first
self.status_cache = nil
public.send_status(plc_state.degraded)
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("sent out status cache again, did supervisor miss it?")
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
-- request for physical structure
@@ -738,8 +765,11 @@ function plc.comms(id, version, modem, local_port, server_port, reactor, rps, co
self.r_seq_num = nil
self.status_cache = nil
_send_struct()
public.send_status(plc_state.degraded)
if plc_state.reactor_formed then
_send_struct()
end
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("sent initial status data")
elseif link_ack == RPLC_LINKING.DENY then