#33 lua module/require architecture changeover
This commit is contained in:
@@ -1,7 +1,10 @@
|
||||
-- #REQUIRES types.lua
|
||||
-- #REQUIRES comms.lua
|
||||
-- #REQUIRES ppm.lua
|
||||
-- #REQUIRES util.lua
|
||||
local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local plc = {}
|
||||
|
||||
local iss_status_t = types.iss_status_t
|
||||
|
||||
@@ -18,7 +21,7 @@ local println_ts = util.println_ts
|
||||
-- Internal Safety System
|
||||
-- identifies dangerous states and SCRAMs reactor if warranted
|
||||
-- autonomous from main SCADA supervisor/coordinator control
|
||||
function iss_init(reactor)
|
||||
plc.iss_init = function (reactor)
|
||||
local self = {
|
||||
reactor = reactor,
|
||||
cache = { false, false, false, false, false, false, false },
|
||||
@@ -34,7 +37,7 @@ function iss_init(reactor)
|
||||
local damage_percent = self.reactor.getDamagePercent()
|
||||
if damage_percent == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor damage")
|
||||
log.error("ISS: failed to check reactor damage")
|
||||
return false
|
||||
else
|
||||
return damage_percent >= 100
|
||||
@@ -46,7 +49,7 @@ function iss_init(reactor)
|
||||
local hc_needed = self.reactor.getHeatedCoolantNeeded()
|
||||
if hc_needed == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor heated coolant level")
|
||||
log.error("ISS: failed to check reactor heated coolant level")
|
||||
return false
|
||||
else
|
||||
return hc_needed == 0
|
||||
@@ -58,7 +61,7 @@ function iss_init(reactor)
|
||||
local w_needed = self.reactor.getWasteNeeded()
|
||||
if w_needed == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor waste level")
|
||||
log.error("ISS: failed to check reactor waste level")
|
||||
return false
|
||||
else
|
||||
return w_needed == 0
|
||||
@@ -71,7 +74,7 @@ function iss_init(reactor)
|
||||
local temp = self.reactor.getTemperature()
|
||||
if temp == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor temperature")
|
||||
log.error("ISS: failed to check reactor temperature")
|
||||
return false
|
||||
else
|
||||
return temp >= 1200
|
||||
@@ -83,7 +86,7 @@ function iss_init(reactor)
|
||||
local fuel = self.reactor.getFuel()
|
||||
if fuel == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor fuel level")
|
||||
log.error("ISS: failed to check reactor fuel level")
|
||||
return false
|
||||
else
|
||||
return fuel == 0
|
||||
@@ -95,7 +98,7 @@ function iss_init(reactor)
|
||||
local coolant_filled = self.reactor.getCoolantFilledPercentage()
|
||||
if coolant_filled == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
log._error("ISS: failed to check reactor coolant level")
|
||||
log.error("ISS: failed to check reactor coolant level")
|
||||
return false
|
||||
else
|
||||
return coolant_filled < 0.02
|
||||
@@ -134,25 +137,25 @@ function iss_init(reactor)
|
||||
if self.tripped then
|
||||
status = self.trip_cause
|
||||
elseif self.cache[1] then
|
||||
log._warning("ISS: damage critical!")
|
||||
log.warning("ISS: damage critical!")
|
||||
status = iss_status_t.dmg_crit
|
||||
elseif self.cache[4] then
|
||||
log._warning("ISS: high temperature!")
|
||||
log.warning("ISS: high temperature!")
|
||||
status = iss_status_t.high_temp
|
||||
elseif self.cache[2] then
|
||||
log._warning("ISS: heated coolant backup!")
|
||||
log.warning("ISS: heated coolant backup!")
|
||||
status = iss_status_t.ex_hcoolant
|
||||
elseif self.cache[6] then
|
||||
log._warning("ISS: no coolant!")
|
||||
log.warning("ISS: no coolant!")
|
||||
status = iss_status_t.no_coolant
|
||||
elseif self.cache[3] then
|
||||
log._warning("ISS: full waste!")
|
||||
log.warning("ISS: full waste!")
|
||||
status = iss_status_t.ex_waste
|
||||
elseif self.cache[5] then
|
||||
log._warning("ISS: no fuel!")
|
||||
log.warning("ISS: no fuel!")
|
||||
status = iss_status_t.no_fuel
|
||||
elseif self.cache[7] then
|
||||
log._warning("ISS: supervisor connection timeout!")
|
||||
log.warning("ISS: supervisor connection timeout!")
|
||||
status = iss_status_t.timeout
|
||||
else
|
||||
self.tripped = false
|
||||
@@ -161,7 +164,7 @@ function iss_init(reactor)
|
||||
-- if a new trip occured...
|
||||
local first_trip = false
|
||||
if not was_tripped and status ~= iss_status_t.ok then
|
||||
log._warning("ISS: reactor SCRAM")
|
||||
log.warning("ISS: reactor SCRAM")
|
||||
|
||||
first_trip = true
|
||||
self.tripped = true
|
||||
@@ -169,7 +172,7 @@ function iss_init(reactor)
|
||||
|
||||
self.reactor.scram()
|
||||
if self.reactor.__p_is_faulted() then
|
||||
log._error("ISS: failed reactor SCRAM")
|
||||
log.error("ISS: failed reactor SCRAM")
|
||||
end
|
||||
end
|
||||
|
||||
@@ -198,7 +201,7 @@ function iss_init(reactor)
|
||||
end
|
||||
|
||||
-- reactor PLC communications
|
||||
function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
plc.comms = function (id, modem, local_port, server_port, reactor, iss)
|
||||
local self = {
|
||||
id = id,
|
||||
seq_num = 0,
|
||||
@@ -355,7 +358,7 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
if not self.reactor.__p_is_faulted() then
|
||||
_send(RPLC_TYPES.MEK_STRUCT, mek_data)
|
||||
else
|
||||
log._error("failed to send structure: PPM fault")
|
||||
log.error("failed to send structure: PPM fault")
|
||||
end
|
||||
end
|
||||
|
||||
@@ -417,7 +420,7 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
if not self.reactor.__p_is_faulted() then
|
||||
_send(RPLC_TYPES.STATUS, sys_status)
|
||||
else
|
||||
log._error("failed to send status: PPM fault")
|
||||
log.error("failed to send status: PPM fault")
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -463,7 +466,7 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
pkt = mgmt_pkt.get()
|
||||
end
|
||||
else
|
||||
log._error("illegal packet type " .. s_pkt.protocol(), true)
|
||||
log.error("illegal packet type " .. s_pkt.protocol(), true)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -477,7 +480,7 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
if self.r_seq_num == nil then
|
||||
self.r_seq_num = packet.scada_frame.seq_num()
|
||||
elseif self.linked and self.r_seq_num >= packet.scada_frame.seq_num() then
|
||||
log._warning("sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
|
||||
log.warning("sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
|
||||
return
|
||||
else
|
||||
self.r_seq_num = packet.scada_frame.seq_num()
|
||||
@@ -496,19 +499,19 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
local trip_time = util.time() - timestamp
|
||||
|
||||
if trip_time > 500 then
|
||||
log._warning("PLC KEEP_ALIVE trip time > 500ms (" .. trip_time .. ")")
|
||||
log.warning("PLC KEEP_ALIVE trip time > 500ms (" .. trip_time .. ")")
|
||||
end
|
||||
|
||||
-- log._debug("RPLC RTT = ".. trip_time .. "ms")
|
||||
-- log.debug("RPLC RTT = ".. trip_time .. "ms")
|
||||
|
||||
_send_keep_alive_ack(timestamp)
|
||||
else
|
||||
log._debug("RPLC keep alive packet length mismatch")
|
||||
log.debug("RPLC keep alive packet length mismatch")
|
||||
end
|
||||
elseif packet.type == RPLC_TYPES.LINK_REQ then
|
||||
-- link request confirmation
|
||||
if packet.length == 1 then
|
||||
log._debug("received unsolicited link request response")
|
||||
log.debug("received unsolicited link request response")
|
||||
|
||||
local link_ack = packet.data[1]
|
||||
|
||||
@@ -516,31 +519,31 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
self.status_cache = nil
|
||||
_send_struct()
|
||||
send_status(plc_state.degraded)
|
||||
log._debug("re-sent initial status data")
|
||||
log.debug("re-sent initial status data")
|
||||
elseif link_ack == RPLC_LINKING.DENY then
|
||||
println_ts("received unsolicited link denial, unlinking")
|
||||
log._debug("unsolicited RPLC link request denied")
|
||||
log.debug("unsolicited RPLC link request denied")
|
||||
elseif link_ack == RPLC_LINKING.COLLISION then
|
||||
println_ts("received unsolicited link collision, unlinking")
|
||||
log._warning("unsolicited RPLC link request collision")
|
||||
log.warning("unsolicited RPLC link request collision")
|
||||
else
|
||||
println_ts("invalid unsolicited link response")
|
||||
log._error("unsolicited unknown RPLC link request response")
|
||||
log.error("unsolicited unknown RPLC link request response")
|
||||
end
|
||||
|
||||
self.linked = link_ack == RPLC_LINKING.ALLOW
|
||||
else
|
||||
log._debug("RPLC link req packet length mismatch")
|
||||
log.debug("RPLC link req packet length mismatch")
|
||||
end
|
||||
elseif packet.type == RPLC_TYPES.STATUS then
|
||||
-- request of full status, clear cache first
|
||||
self.status_cache = nil
|
||||
send_status(plc_state.degraded)
|
||||
log._debug("sent out status cache again, did supervisor miss it?")
|
||||
log.debug("sent out status cache again, did supervisor miss it?")
|
||||
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
|
||||
-- request for physical structure
|
||||
_send_struct()
|
||||
log._debug("sent out structure again, did supervisor miss it?")
|
||||
log.debug("sent out structure again, did supervisor miss it?")
|
||||
elseif packet.type == RPLC_TYPES.MEK_SCRAM then
|
||||
-- disable the reactor
|
||||
self.scrammed = true
|
||||
@@ -576,14 +579,14 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
|
||||
_send_ack(packet.type, success)
|
||||
else
|
||||
log._debug("RPLC set burn rate packet length mismatch")
|
||||
log.debug("RPLC set burn rate packet length mismatch")
|
||||
end
|
||||
elseif packet.type == RPLC_TYPES.ISS_CLEAR then
|
||||
-- clear the ISS status
|
||||
iss.reset()
|
||||
_send_ack(packet.type, true)
|
||||
else
|
||||
log._warning("received unknown RPLC packet type " .. packet.type)
|
||||
log.warning("received unknown RPLC packet type " .. packet.type)
|
||||
end
|
||||
elseif packet.type == RPLC_TYPES.LINK_REQ then
|
||||
-- link request confirmation
|
||||
@@ -592,7 +595,7 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
|
||||
if link_ack == RPLC_LINKING.ALLOW then
|
||||
println_ts("linked!")
|
||||
log._debug("RPLC link request approved")
|
||||
log.debug("RPLC link request approved")
|
||||
|
||||
-- reset remote sequence number and cache
|
||||
self.r_seq_num = nil
|
||||
@@ -601,24 +604,24 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
_send_struct()
|
||||
send_status(plc_state.degraded)
|
||||
|
||||
log._debug("sent initial status data")
|
||||
log.debug("sent initial status data")
|
||||
elseif link_ack == RPLC_LINKING.DENY then
|
||||
println_ts("link request denied, retrying...")
|
||||
log._debug("RPLC link request denied")
|
||||
log.debug("RPLC link request denied")
|
||||
elseif link_ack == RPLC_LINKING.COLLISION then
|
||||
println_ts("reactor PLC ID collision (check config), retrying...")
|
||||
log._warning("RPLC link request collision")
|
||||
log.warning("RPLC link request collision")
|
||||
else
|
||||
println_ts("invalid link response, bad channel? retrying...")
|
||||
log._error("unknown RPLC link request response")
|
||||
log.error("unknown RPLC link request response")
|
||||
end
|
||||
|
||||
self.linked = link_ack == RPLC_LINKING.ALLOW
|
||||
else
|
||||
log._debug("RPLC link req packet length mismatch")
|
||||
log.debug("RPLC link req packet length mismatch")
|
||||
end
|
||||
else
|
||||
log._debug("discarding non-link packet before linked")
|
||||
log.debug("discarding non-link packet before linked")
|
||||
end
|
||||
elseif packet.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
|
||||
-- handle session close
|
||||
@@ -626,9 +629,9 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
conn_watchdog.cancel()
|
||||
unlink()
|
||||
println_ts("server connection closed by remote host")
|
||||
log._warning("server connection closed by remote host")
|
||||
log.warning("server connection closed by remote host")
|
||||
else
|
||||
log._warning("received unknown SCADA_MGMT packet type " .. packet.type)
|
||||
log.warning("received unknown SCADA_MGMT packet type " .. packet.type)
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -652,3 +655,5 @@ function comms_init(id, modem, local_port, server_port, reactor, iss)
|
||||
is_linked = is_linked
|
||||
}
|
||||
end
|
||||
|
||||
return plc
|
||||
|
||||
Reference in New Issue