#33 lua module/require architecture changeover

This commit is contained in:
Mikayla Fischler
2022-05-04 13:37:01 -04:00
parent 7bcb260712
commit b575899d46
33 changed files with 679 additions and 518 deletions

View File

@@ -0,0 +1,3 @@
local coordinator = {}
return coordinator

View File

@@ -1,7 +1,9 @@
-- #REQUIRES mqueue.lua
-- #REQUIRES comms.lua
-- #REQUIRES log.lua
-- #REQUIRES util.lua
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local plc = {}
local PROTOCOLS = comms.PROTOCOLS
local RPLC_TYPES = comms.RPLC_TYPES
@@ -16,19 +18,21 @@ local println_ts = util.println_ts
local INITIAL_WAIT = 1500
local RETRY_PERIOD = 1000
PLC_S_CMDS = {
local PLC_S_CMDS = {
SCRAM = 0,
ENABLE = 1,
BURN_RATE = 2,
ISS_CLEAR = 3
}
plc.PLC_S_CMDS = PLC_S_CMDS
local PERIODICS = {
KEEP_ALIVE = 2.0
}
-- PLC supervisor session
function new_session(id, for_reactor, in_queue, out_queue)
plc.new_session = function (id, for_reactor, in_queue, out_queue)
local log_header = "plc_session(" .. id .. "): "
local self = {
@@ -204,7 +208,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
if pkt.length == 1 then
return pkt.data[1]
else
log._warning(log_header .. "RPLC ACK length mismatch")
log.warning(log_header .. "RPLC ACK length mismatch")
return nil
end
end
@@ -215,7 +219,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
if self.r_seq_num == nil then
self.r_seq_num = pkt.scada_frame.seq_num()
elseif self.r_seq_num >= pkt.scada_frame.seq_num() then
log._warning(log_header .. "sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. pkt.scada_frame.seq_num())
log.warning(log_header .. "sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. pkt.scada_frame.seq_num())
return
else
self.r_seq_num = pkt.scada_frame.seq_num()
@@ -225,7 +229,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
if pkt.scada_frame.protocol() == PROTOCOLS.RPLC then
-- check reactor ID
if pkt.id ~= for_reactor then
log._warning(log_header .. "RPLC packet with ID not matching reactor ID: reactor " .. self.for_reactor .. " != " .. pkt.id)
log.warning(log_header .. "RPLC packet with ID not matching reactor ID: reactor " .. self.for_reactor .. " != " .. pkt.id)
return
end
@@ -242,13 +246,13 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.last_rtt = srv_now - srv_start
if self.last_rtt > 500 then
log._warning(log_header .. "PLC KEEP_ALIVE round trip time > 500ms (" .. self.last_rtt .. ")")
log.warning(log_header .. "PLC KEEP_ALIVE round trip time > 500ms (" .. self.last_rtt .. ")")
end
-- log._debug(log_header .. "RPLC RTT = ".. self.last_rtt .. "ms")
-- log._debug(log_header .. "RPLC TT = ".. (srv_now - plc_send) .. "ms")
-- log.debug(log_header .. "RPLC RTT = ".. self.last_rtt .. "ms")
-- log.debug(log_header .. "RPLC TT = ".. (srv_now - plc_send) .. "ms")
else
log._debug(log_header .. "RPLC keep alive packet length mismatch")
log.debug(log_header .. "RPLC keep alive packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.STATUS then
-- status packet received, update data
@@ -267,11 +271,11 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.received_status_cache = true
else
-- error copying status data
log._error(log_header .. "failed to parse status packet data")
log.error(log_header .. "failed to parse status packet data")
end
end
else
log._debug(log_header .. "RPLC status packet length mismatch")
log.debug(log_header .. "RPLC status packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.MEK_STRUCT then
-- received reactor structure, record it
@@ -282,10 +286,10 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.received_struct = true
else
-- error copying structure data
log._error(log_header .. "failed to parse struct packet data")
log.error(log_header .. "failed to parse struct packet data")
end
else
log._debug(log_header .. "RPLC struct packet length mismatch")
log.debug(log_header .. "RPLC struct packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.MEK_SCRAM then
-- SCRAM acknowledgement
@@ -294,7 +298,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.acks.scram = true
self.sDB.control_state = false
elseif ack == false then
log._debug(log_header .. "SCRAM failed!")
log.debug(log_header .. "SCRAM failed!")
end
elseif pkt.type == RPLC_TYPES.MEK_ENABLE then
-- enable acknowledgement
@@ -303,7 +307,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.acks.enable = true
self.sDB.control_state = true
elseif ack == false then
log._debug(log_header .. "enable failed!")
log.debug(log_header .. "enable failed!")
end
elseif pkt.type == RPLC_TYPES.MEK_BURN_RATE then
-- burn rate acknowledgement
@@ -311,7 +315,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
if ack then
self.acks.burn_rate = true
elseif ack == false then
log._debug(log_header .. "burn rate update failed!")
log.debug(log_header .. "burn rate update failed!")
end
elseif pkt.type == RPLC_TYPES.ISS_STATUS then
-- ISS status packet received, copy data
@@ -321,10 +325,10 @@ function new_session(id, for_reactor, in_queue, out_queue)
-- copied in ISS status data OK
else
-- error copying ISS status data
log._error(log_header .. "failed to parse ISS status packet data")
log.error(log_header .. "failed to parse ISS status packet data")
end
else
log._debug(log_header .. "RPLC ISS status packet length mismatch")
log.debug(log_header .. "RPLC ISS status packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.ISS_ALARM then
-- ISS alarm
@@ -337,10 +341,10 @@ function new_session(id, for_reactor, in_queue, out_queue)
-- copied in ISS status data OK
else
-- error copying ISS status data
log._error(log_header .. "failed to parse ISS alarm status data")
log.error(log_header .. "failed to parse ISS alarm status data")
end
else
log._debug(log_header .. "RPLC ISS alarm packet length mismatch")
log.debug(log_header .. "RPLC ISS alarm packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.ISS_CLEAR then
-- ISS clear acknowledgement
@@ -350,17 +354,17 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.sDB.iss_tripped = false
self.sDB.iss_trip_cause = "ok"
elseif ack == false then
log._debug(log_header .. "ISS clear failed")
log.debug(log_header .. "ISS clear failed")
end
else
log._debug(log_header .. "handler received unsupported RPLC packet type " .. pkt.type)
log.debug(log_header .. "handler received unsupported RPLC packet type " .. pkt.type)
end
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
if pkt.type == SCADA_MGMT_TYPES.CLOSE then
-- close the session
self.connected = false
else
log._debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end
end
end
@@ -402,7 +406,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
self.connected = false
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
println("connection to reactor " .. self.for_reactor .. " PLC closed by server")
log._info(log_header .. "session closed by server")
log.info(log_header .. "session closed by server")
end
-- iterate the session
@@ -454,7 +458,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log._warning(log_header .. "exceeded 100ms queue process limit")
log.warning(log_header .. "exceeded 100ms queue process limit")
break
end
end
@@ -463,7 +467,7 @@ function new_session(id, for_reactor, in_queue, out_queue)
if not self.connected then
self.plc_conn_watchdog.cancel()
println("connection to reactor " .. self.for_reactor .. " PLC closed by remote host")
log._info(log_header .. "session closed by remote host")
log.info(log_header .. "session closed by remote host")
return self.connected
end
@@ -559,3 +563,5 @@ function new_session(id, for_reactor, in_queue, out_queue)
iterate = iterate
}
end
return plc

View File

@@ -0,0 +1,3 @@
local rtu = {}
return rtu

View File

@@ -1,14 +1,22 @@
-- #REQUIRES mqueue.lua
-- #REQUIRES log.lua
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local coordinator = require("session.coordinator")
local plc = require("session.plc")
local rtu = require("session.rtu")
-- Supervisor Sessions Handler
SESSION_TYPE = {
local svsessions = {}
local SESSION_TYPE = {
RTU_SESSION = 0,
PLC_SESSION = 1,
COORD_SESSION = 2
}
svsessions.SESSION_TYPE = SESSION_TYPE
local self = {
modem = nil,
num_reactors = 0,
@@ -20,12 +28,97 @@ local self = {
next_coord_id = 0
}
function link_modem(modem)
-- PRIVATE FUNCTIONS --
-- iterate all the given sessions
local function _iterate(sessions)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
local ok = session.instance.iterate()
if ok then
-- send packets in out queue
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
end
end
else
session.open = false
end
end
end
end
-- cleanly close a session
local function _shutdown(session)
session.open = false
session.instance.close()
-- send packets in out queue (namely the close packet)
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
end
end
log.debug("closed session " .. session.instance.get_id() .. " on remote port " .. session.r_port)
end
-- close connections
local function _close(sessions)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
_shutdown(session)
end
end
end
-- check if a watchdog timer event matches that of one of the provided sessions
local function _check_watchdogs(sessions, timer_event)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
local triggered = session.instance.check_wd(timer_event)
if triggered then
log.debug("watchdog closing session " .. session.instance.get_id() .. " on remote port " .. session.r_port .. "...")
_shutdown(session)
end
end
end
end
-- delete any closed sessions
local function _free_closed(sessions)
local move_to = 1
for i = 1, #sessions do
local session = sessions[i]
if session ~= nil then
if sessions[i].open then
if sessions[move_to] == nil then
sessions[move_to] = session
sessions[i] = nil
end
move_to = move_to + 1
else
log.debug("free'ing closed session " .. session.instance.get_id() .. " on remote port " .. session.r_port)
sessions[i] = nil
end
end
end
end
-- PUBLIC FUNCTIONS --
svsessions.link_modem = function (modem)
self.modem = modem
end
-- find a session by the remote port
function find_session(remote_port)
svsessions.find_session = function (remote_port)
-- check RTU sessions
for i = 1, #self.rtu_sessions do
if self.rtu_sessions[i].r_port == remote_port then
@@ -51,7 +144,7 @@ function find_session(remote_port)
end
-- get a session by reactor ID
function get_reactor_session(reactor)
svsessions.get_reactor_session = function (reactor)
local session = nil
for i = 1, #self.plc_sessions do
@@ -64,8 +157,8 @@ function get_reactor_session(reactor)
end
-- establish a new PLC session
function establish_plc_session(local_port, remote_port, for_reactor)
if get_reactor_session(for_reactor) == nil then
svsessions.establish_plc_session = function (local_port, remote_port, for_reactor)
if svsessions.get_reactor_session(for_reactor) == nil then
local plc_s = {
open = true,
reactor = for_reactor,
@@ -79,7 +172,7 @@ function establish_plc_session(local_port, remote_port, for_reactor)
plc_s.instance = plc.new_session(self.next_plc_id, for_reactor, plc_s.in_queue, plc_s.out_queue)
table.insert(self.plc_sessions, plc_s)
log._debug("established new PLC session to " .. remote_port .. " with ID " .. self.next_plc_id)
log.debug("established new PLC session to " .. remote_port .. " with ID " .. self.next_plc_id)
self.next_plc_id = self.next_plc_id + 1
@@ -91,38 +184,8 @@ function establish_plc_session(local_port, remote_port, for_reactor)
end
end
-- cleanly close a session
local function _shutdown(session)
session.open = false
session.instance.close()
-- send packets in out queue (namely the close packet)
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
end
end
log._debug("closed session " .. session.instance.get_id() .. " on remote port " .. session.r_port)
end
-- check if a watchdog timer event matches that of one of the provided sessions
local function _check_watchdogs(sessions, timer_event)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
local triggered = session.instance.check_wd(timer_event)
if triggered then
log._debug("watchdog closing session " .. session.instance.get_id() .. " on remote port " .. session.r_port .. "...")
_shutdown(session)
end
end
end
end
-- attempt to identify which session's watchdog timer fired
function check_all_watchdogs(timer_event)
svsessions.check_all_watchdogs = function (timer_event)
-- check RTU session watchdogs
_check_watchdogs(self.rtu_sessions, timer_event)
@@ -133,29 +196,8 @@ function check_all_watchdogs(timer_event)
_check_watchdogs(self.coord_sessions, timer_event)
end
-- iterate all the given sessions
local function _iterate(sessions)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
local ok = session.instance.iterate()
if ok then
-- send packets in out queue
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
end
end
else
session.open = false
end
end
end
end
-- iterate all sessions
function iterate_all()
svsessions.iterate_all = function ()
-- iterate RTU sessions
_iterate(self.rtu_sessions)
@@ -166,28 +208,8 @@ function iterate_all()
_iterate(self.coord_sessions)
end
-- delete any closed sessions
local function _free_closed(sessions)
local move_to = 1
for i = 1, #sessions do
local session = sessions[i]
if session ~= nil then
if sessions[i].open then
if sessions[move_to] == nil then
sessions[move_to] = session
sessions[i] = nil
end
move_to = move_to + 1
else
log._debug("free'ing closed session " .. session.instance.get_id() .. " on remote port " .. session.r_port)
sessions[i] = nil
end
end
end
end
-- delete all closed sessions
function free_all_closed()
svsessions.free_all_closed = function ()
-- free closed RTU sessions
_free_closed(self.rtu_sessions)
@@ -198,23 +220,15 @@ function free_all_closed()
_free_closed(self.coord_sessions)
end
-- close connections
local function _close(sessions)
for i = 1, #sessions do
local session = sessions[i]
if session.open then
_shutdown(session)
end
end
end
-- close all open connections
function close_all()
svsessions.close_all = function ()
-- close sessions
_close(self.rtu_sessions)
_close(self.plc_sessions)
_close(self.coord_sessions)
-- free sessions
free_all_closed()
svsessions.free_all_closed()
end
return svsessions