#479 WIP sodium emergency coolant fixes
This commit is contained in:
@@ -2,8 +2,11 @@
|
||||
-- Basic Unit Flow Overview
|
||||
--
|
||||
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
local style = require("coordinator.ui.style")
|
||||
|
||||
local core = require("graphics.core")
|
||||
@@ -19,6 +22,8 @@ local DataIndicator = require("graphics.elements.indicators.DataIndicator")
|
||||
local IndicatorLight = require("graphics.elements.indicators.IndicatorLight")
|
||||
local TriIndicatorLight = require("graphics.elements.indicators.TriIndicatorLight")
|
||||
|
||||
local COOLANT_TYPE = types.COOLANT_TYPE
|
||||
|
||||
local ALIGN = core.ALIGN
|
||||
|
||||
local sprintf = util.sprintf
|
||||
@@ -35,8 +40,8 @@ local lg_gray = style.lg_gray
|
||||
---@param x integer top left x
|
||||
---@param y integer top left y
|
||||
---@param wide boolean whether to render wide version
|
||||
---@param unit ioctl_unit unit database entry
|
||||
local function make(parent, x, y, wide, unit)
|
||||
---@param unit_id integer unit index
|
||||
local function make(parent, x, y, wide, unit_id)
|
||||
local s_field = style.theme.field_box
|
||||
|
||||
local text_c = style.text_colors
|
||||
@@ -48,6 +53,13 @@ local function make(parent, x, y, wide, unit)
|
||||
|
||||
local height = 16
|
||||
|
||||
local facility = iocontrol.get_db().facility
|
||||
local unit = iocontrol.get_db().units[unit_id]
|
||||
|
||||
local tank_defs = facility.tank_defs
|
||||
local tank_conns = facility.tank_conns
|
||||
local tank_types = facility.tank_fluid_types
|
||||
|
||||
local v_start = 1 + ((unit.unit_id - 1) * 5)
|
||||
local prv_start = 1 + ((unit.unit_id - 1) * 3)
|
||||
local v_fields = { "pu", "po", "pl", "am" }
|
||||
@@ -80,21 +92,22 @@ local function make(parent, x, y, wide, unit)
|
||||
|
||||
local rc_pipes = {}
|
||||
|
||||
local emc_x = 42 -- emergency coolant connection x point
|
||||
|
||||
if unit.num_boilers > 0 then
|
||||
table.insert(rc_pipes, pipe(0, 1, _wide(28, 19), 1, colors.lightBlue, true))
|
||||
table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true))
|
||||
table.insert(rc_pipes, pipe(_wide(46 ,39), 1, _wide(72,58), 1, colors.blue, true))
|
||||
table.insert(rc_pipes, pipe(_wide(46,39), 3, _wide(72,58), 3, colors.white, true))
|
||||
else
|
||||
emc_x = 3
|
||||
table.insert(rc_pipes, pipe(0, 1, _wide(72,58), 1, colors.blue, true))
|
||||
table.insert(rc_pipes, pipe(0, 3, _wide(72,58), 3, colors.white, true))
|
||||
end
|
||||
|
||||
if unit.has_tank then
|
||||
table.insert(rc_pipes, pipe(emc_x, 1, emc_x, 0, colors.blue, true, true))
|
||||
local is_water = tank_types[tank_conns[unit_id]] == COOLANT_TYPE.WATER
|
||||
-- emergency coolant connection x point
|
||||
local emc_x = util.trinary(is_water and (unit.num_boilers > 0), 42, 3)
|
||||
|
||||
table.insert(rc_pipes, pipe(emc_x, 1, emc_x, 0, util.trinary(is_water, colors.blue, colors.lightBlue), true, true))
|
||||
end
|
||||
|
||||
local prv_yo = math.max(3 - unit.num_turbines, 0)
|
||||
|
||||
Reference in New Issue